Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Regina Mundi Catholic College: Difference between revisions

From FireAlarmPedia
mNo edit summary
Line 30: Line 30:
Most of the pull stations are the original first generation Edwards 270-SPO pull stations. In the 1988 parts, there are newer Edwards 270A-SPO pull stations. The tech wing, however has a few Mirtone 73201 dual-action pull stations.
Most of the pull stations are the original first generation Edwards 270-SPO pull stations. In the 1988 parts, there are newer Edwards 270A-SPO pull stations. The tech wing, however has a few Mirtone 73201 dual-action pull stations.
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
There are Edwards 6249C photoelectric smoke detectors and Edwards 281C rate-of-rise/fixed-temperature heat detectors located throughout the school, installled in 1988. There is a Chemtronics 501 rate-of-rise heat detector behind the chapel, which might be original. There is also a System Sensor 2151A photoelectric smoke detector mounted on a B114LPA base, installed as a deficiency replacement.
There are Edwards 6250C ionization smoke detectors and Edwards 281C rate-of-rise/fixed-temperature heat detectors located throughout the school, installed in 1988. There is an original Edwards 241 rate-of-rise/fixed heat detector behind the chapel. There is also a System Sensor 2151A photoelectric smoke detector mounted on a B114LPA base, installed as a deficiency replacement.
== System Specifications (English and Dance Portables) ==
== System Specifications (English and Dance Portables) ==
{| style="float:right;border:2px solid black"
{| style="float:right;border:2px solid black"
Line 51: Line 51:
The pull stations are Edwards 270-SPO pull stations.
The pull stations are Edwards 270-SPO pull stations.
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
The smoke detectors are Edwards 6249C photoelectric smoke detectors.
All smoke detectors are Edwards 6250C ionization smoke detectors.
== System Specifications (Religion Portable) ==
== System Specifications (Religion Portable) ==
{| style="float:right;border:2px solid black"
{| style="float:right;border:2px solid black"

Revision as of 11:06, 25 December 2023

System Specifications
FACP: Edwards Custom 6500

FACP Location: Mechanical Room
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VDC (some bells 4VDC, and one bell 12VAC,

likely on transformers.)

System Coding: March Time
Date of last known Upgrade: Late 2000s
Year Opened: 1963, 1988

Regina Mundi Catholic College is a catholic high school located at 5250 Wellington Rd S in London, Ontario. It was the second Catholic school to be built in Ontario. It was first built in 1963 as a seminary for boys, then an all boys school in 1967, and in 1983 added a gymnasium and science laboratories as a co-ed school. It was then expanded in 1988 as a high school. The fire alarm system was upgraded in 1988, but some of the bells and pull stations remain original.

There are also portables built between 1988 and 2000, which are independent from the main system, however all systems are wired to trip each other when one goes into alarm. The 2nd and 3rd floors were originally dorms, but were converted to classrooms.

System Specifications

FACP

The school is protected by an Edwards 6500 conventional fire alarm system. The panel is located in the mechanical room in the basement, and has an auxiliary panel for additional zones. It has a total of 52 zones. The 6500 was installed in 1988 after the major expansion. The system coding is march time.

Annunciators

There is an annunciator for the Edwards 6500 located in the front foyer, model unknown.

Notification Appliances

Most of the notification appliances are the original Edwards "Adaptabel" model 23 single-stroke bells (10" gong, 4VDC) The library and cafeteria have one original Edwards model 23 bell each, as well as one Edwards 439D-10AWC (10" gong) vibrating bell, installed during the 1988 renovation. In the double gymnasium added in 1988, there are Edwards 439D-10AWC vibrating bells (10" gong).

In the science wing, there is one original Edwards bell, and an Edwards "Adaptabel" 333D single-stroke bell (10" gong) installed as a deficiency replacement. The music room also has an Edwards 439D-10AWC bell, and in the hallway outside of it, an Edwards "Adaptabel" model 24 single-stroke bell (10" gong, 12VAC).

Technology Wing (1988)

There is an Edwards 439D-6AWC vibrating bell (6" gong) in a hallway, and Edwards 439D-10AWC vibrating bells (10", including one in a storage room due to that part being formerly being a hallway.

Initiating Devices

Pull Stations

Most of the pull stations are the original first generation Edwards 270-SPO pull stations. In the 1988 parts, there are newer Edwards 270A-SPO pull stations. The tech wing, however has a few Mirtone 73201 dual-action pull stations.

Automatic Detection Devices

There are Edwards 6250C ionization smoke detectors and Edwards 281C rate-of-rise/fixed-temperature heat detectors located throughout the school, installed in 1988. There is an original Edwards 241 rate-of-rise/fixed heat detector behind the chapel. There is also a System Sensor 2151A photoelectric smoke detector mounted on a B114LPA base, installed as a deficiency replacement.

System Specifications (English and Dance Portables)

System Specifications
FACP: EST 6632

FACP Location: In-portable
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR

System Coding: Continuous
Date of last known Upgrade: Late 1990s
Year Opened: 1988

FACP

The portable is protected by an EST 6632 conventional fire alarm system. The panel replaced an Edwards 6602. The system coding is continuous.

Notification Appliances

The notification appliances are Edwards 439D-10AWC vibrating bells (10" gong)

Initiating Devices

Pull Stations

The pull stations are Edwards 270-SPO pull stations.

Automatic Detection Devices

All smoke detectors are Edwards 6250C ionization smoke detectors.

System Specifications (Religion Portable)

System Specifications
FACP: Mircom FA-101T

FACP Location: In-Portable
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR

System Coding: Temporal
Date of last known Upgrade: 2000s
Year Opened: Early 1990s

FACP

The portable is protected by a Mircom FA-101T conventional fire alarm system. The panel replaced an older Edwards panel in the 2000s. The system coding is temporal.

Notification Appliances

The notification appliances are Mircom BL-6B motor bells (6" gong)

Initiating Devices

Pull Stations

The pull stations are Mircom MS-401 pull stations in the hallways, and Edwards 275-C111 pull stations in the classes, leftover from the previous system.

Automatic Detection Devices

None noticed.