Shoppers Drug Mart (Walden): Difference between revisions

From FireAlarmPedia
(Completely rewrote the page, plus a new system! Bye bye Garbageplex.)
No edit summary
Line 7: Line 7:
| FACP: Notifier NFS-320C <br />FACP Location: Main Electrical Room <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, SS <br />Date of last known Upgrade: 2023 <br />Year Opened: 2011
| FACP: Notifier NFS-320C <br />FACP Location: Main Electrical Room <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, SS <br />Date of last known Upgrade: 2023 <br />Year Opened: 2011
|}
|}
 
'''Shoppers Drug Mart''' is a Canadian chain of pharmacies owned by Loblaws. This particular pharmacy is located at 1511 Walden Gate Southeast (Unit 700), in Calgary, Alberta, Canada. The pharmacy opened in 2011, and the fire alarm system was fully upgraded in 2023.
'''Shoppers Drug Mart''' is a Canadian chain of pharmacies owned by Loblaws. This particular pharmacy is located at 1511 Walden Gate Southeast (Unit 700), in Calgary, Alberta, Canada. The pharmacy opened in 2011, and the fire alarm system was fully upgraded in 2023.
 
==System Specifications (2023-present)==
==System Specifications (2023-present)==
====FACP====
====FACP====
The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel is located in the main electrical room. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.
The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel is located in the main electrical room. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.
 
=====Annunciators=====
=====Annunciators=====
There is a Notifier LCD2-80 annunciator paired with a Notifier ACM-24AT annunciator in the main entrance vestibule.
There is a Notifier LCD2-80 annunciator paired with a Notifier ACM-24AT annunciator in the main entrance vestibule.
====Notification Appliances====
====Notification Appliances====
Most notification appliances are System Sensor “L-Series” P2RLA horn/strobes (red, wall-mount, bilingual lettering, set to 15cd). Areas with lower ceilings have System Sensor PC2RLA horn/strobes (red, ceiling-mount, bilingual lettering, set to 15cd).
Most notification appliances are System Sensor “L-Series” P2RLA horn/strobes (red, wall-mount, bilingual lettering, set to 15cd). Areas with lower ceilings have System Sensor PC2RLA horn/strobes (red, ceiling-mount, bilingual lettering, set to 15cd).
 
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are Notifier NBG-12LX addressable dual-action pull stations.
All pull stations are Notifier NBG-12LX addressable dual-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
None noticed.
None noticed.
====Modules====
====Modules====
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
==System Specifications (2011-2023)==
==System Specifications (2011-2023)==
{| style="float:right;border:2px solid black"
{| style="float:right;border:2px solid black"
Line 39: Line 31:
| FACP: Simplex 4010 <br />FACP Location: Main Electrical Room <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, SmartSync <br />Year Decommissioned: 2023 <br />Year Installed: 2011
| FACP: Simplex 4010 <br />FACP Location: Main Electrical Room <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, SmartSync <br />Year Decommissioned: 2023 <br />Year Installed: 2011
|}
|}
====FACP====
====FACP====
The building was protected by a Simplex 4010 addressable fire alarm system. The panel was located in the main electrical room. The system ran Simplex’s IDNet addressable protocol, and the system coding was temporal.
The building was protected by a Simplex 4010 addressable fire alarm system. The panel was located in the main electrical room. The system ran Simplex’s IDNet addressable protocol, and the system coding was temporal.
 
=====Annunciators=====
=====Annunciators=====
There was a Simplex 4606-9101 annunciator in the main entrance vestibule.
There was a Simplex 4606-9101 annunciator in the main entrance vestibule.
====Notification Appliances====
====Notification Appliances====
Most notification appliances were Simplex “TrueAlert” 4906-9127 horn/strobes (red, wall-mount, set to 15cd). Areas with lower ceilings had Simplex 4906-9128 horn/strobes (red, ceiling-mount, set to 15cd).
Most notification appliances were Simplex “TrueAlert” 4906-9127 horn/strobes (red, wall-mount, set to 15cd). Areas with lower ceilings had Simplex 4906-9128 horn/strobes (red, ceiling-mount, set to 15cd).
 
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations were Simplex 4099-9001 addressable single-action pull stations.
All pull stations were Simplex 4099-9001 addressable single-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
Not known.
Not known.
====Modules====
====Modules====
There were Simplex 4090-9001 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
There were Simplex 4090-9001 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
[[Category:Calgary]]
[[Category:Drugstores]]

Revision as of 16:15, 27 May 2024

System Specifications
FACP: Notifier NFS-320C
FACP Location: Main Electrical Room
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes, SS
Date of last known Upgrade: 2023
Year Opened: 2011

Shoppers Drug Mart is a Canadian chain of pharmacies owned by Loblaws. This particular pharmacy is located at 1511 Walden Gate Southeast (Unit 700), in Calgary, Alberta, Canada. The pharmacy opened in 2011, and the fire alarm system was fully upgraded in 2023.

System Specifications (2023-present)

FACP

The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel is located in the main electrical room. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.

Annunciators

There is a Notifier LCD2-80 annunciator paired with a Notifier ACM-24AT annunciator in the main entrance vestibule.

Notification Appliances

Most notification appliances are System Sensor “L-Series” P2RLA horn/strobes (red, wall-mount, bilingual lettering, set to 15cd). Areas with lower ceilings have System Sensor PC2RLA horn/strobes (red, ceiling-mount, bilingual lettering, set to 15cd).

Initiating Devices

Pull Stations

All pull stations are Notifier NBG-12LX addressable dual-action pull stations.

Automatic Detection Devices

None noticed.

Modules

There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches.

System Specifications (2011-2023)

System Specifications
FACP: Simplex 4010
FACP Location: Main Electrical Room
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes, SmartSync
Year Decommissioned: 2023
Year Installed: 2011

FACP

The building was protected by a Simplex 4010 addressable fire alarm system. The panel was located in the main electrical room. The system ran Simplex’s IDNet addressable protocol, and the system coding was temporal.

Annunciators

There was a Simplex 4606-9101 annunciator in the main entrance vestibule.

Notification Appliances

Most notification appliances were Simplex “TrueAlert” 4906-9127 horn/strobes (red, wall-mount, set to 15cd). Areas with lower ceilings had Simplex 4906-9128 horn/strobes (red, ceiling-mount, set to 15cd).

Initiating Devices

Pull Stations

All pull stations were Simplex 4099-9001 addressable single-action pull stations.

Automatic Detection Devices

Not known.

Modules

There were Simplex 4090-9001 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.