The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Mircom's Advanced addressable protocol, and the system coding is temporal. | The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Mircom's Advanced addressable protocol, and the system coding is temporal. | ||
==== Notification Appliances ==== | ==== Notification Appliances ==== | ||
All common areas have System Sensor P2RLA horn/strobes (red, wall-mount, bilingual, set to 15cd/electromechanical). All units have Mircom MH-S25WA silenceable mini-horns (white, wall-mount), as well as System Sensor SRLA remote strobes (red, wall-mount). For outdoor notification, there is a System Sensor "SpectrAlert Advance" SRKA weatherproof remote strobe (red, wall-mount) outside the main entrance. | All common areas have System Sensor "L-Series" P2RLA horn/strobes (red, wall-mount, bilingual, set to 15cd/electromechanical). All units have Mircom MH-S25WA silenceable mini-horns (white, wall-mount), as well as System Sensor SRLA remote strobes (red, wall-mount). For outdoor notification, there is a System Sensor "SpectrAlert Advance" SRKA weatherproof remote strobe (red, wall-mount) outside the main entrance. | ||
=== Initiating Devices === | === Initiating Devices === | ||
==== Pull Stations ==== | ==== Pull Stations ==== |
Revision as of 23:38, 10 December 2023
System Specifications |
---|
FACP: Mircom FX-2000
FACP Location: Main Entrance System Coding: Temporal Strobes Synchronized: Yes |
Bishop's Manor, also known by its address 200 Nina Gardens NE is a 5-story apartment building/condominium for low income people located in Bridgeland, NE Calgary. It was built in 2021, and the system is undoubtedly original.
System Specifications (2021-present)
FACP
The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Mircom's Advanced addressable protocol, and the system coding is temporal.
Notification Appliances
All common areas have System Sensor "L-Series" P2RLA horn/strobes (red, wall-mount, bilingual, set to 15cd/electromechanical). All units have Mircom MH-S25WA silenceable mini-horns (white, wall-mount), as well as System Sensor SRLA remote strobes (red, wall-mount). For outdoor notification, there is a System Sensor "SpectrAlert Advance" SRKA weatherproof remote strobe (red, wall-mount) outside the main entrance.
Initiating Devices
Pull Stations
All pull stations are Mircom MS-401AP addressable single-action pull stations.
Automatic Detection Devices
Not available at this time. [[]