There are Fire-Lite MMF-300A addressable monitor modules supervising the sprinkler system’s tamper and flow switches. There are also Fire-Lite CRF-300A addressable relay modules by each fire exit, which cause the door locks to disengage when the system goes into alarm. | There are Fire-Lite MMF-300A addressable monitor modules supervising the sprinkler system’s tamper and flow switches. There are also Fire-Lite CRF-300A addressable relay modules by each fire exit, which cause the door locks to disengage when the system goes into alarm. | ||
==System Specifications (Liquor Store)== | ==System Specifications (Liquor Store)== | ||
{| style="float:right;border:2px solid black" | |||
|- | |||
! System Specifications | |||
|- | |||
| | |||
|- | |||
| FACP: Fire-Lite MS-9600UDLS <br /> FACP Location: Main Entrance Vestibule <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: Temporal <br> Strobes Synchronized: Yes, SS <br />Date of last known Upgrade: N/A <br />Year Opened: 2018 | |||
|} | |||
====FACP==== | ====FACP==== | ||
The store is protected by a Fire-Lite MS-9600UDLS addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Fire-Lite’s LiteSpeed addressable protocol, and the system coding is temporal. This panel is likely wired to the main store’s FACP as an addressable point. | The store is protected by a Fire-Lite MS-9600UDLS addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Fire-Lite’s LiteSpeed addressable protocol, and the system coding is temporal. This panel is likely wired to the main store’s FACP as an addressable point. |
Revision as of 01:42, 13 December 2023
System Specifications |
---|
FACP: Fire-Lite MS-9600UDLS FACP Location: Behind Returns Desk (Main Node) System Type: Addressable System Line Voltage: 120VAC NAC Voltage: 24VDC System Coding: Temporal Strobes Synchronized: Yes, SS Date of last known Upgrade: N/A Year Opened: 2018 |
Costco Wholesale is a chain of big-box stores headquartered in Issaquah, Washington, USA. This particular store is located at 2584 46 Avenue East, in Nisku, Alberta, Canada, adjacent to the [[Edmonton International Airpor]. The store opened in 2018, and the fire alarm system is original.
System Specifications (Main Store)
FACP
The building is protected by a Fire-Lite MS-9600UDLS addressable fire alarm system. The panel is located behind the returns desk. The system runs Fire-Lite’s LiteSpeed addressable protocol, and the system coding is temporal.
Annunciators
There are four Fire-Lite ANN-RLED annunciators on the system. Two are located below the main FACP, and two are located in the main entrance vestibule.
Notification Appliances
Most notification appliances are System Sensor PC2WLA-E horn/strobes (white, ceiling-mount, set to 15cd, English lettering). These are also in areas with low ceilings. There are System Sensor P2RLA-E horn/strobes (red, wall-mount, set to 15cd, English lettering) located at every exit.
The coolers, freezers and exterior have System Sensor “SpectrAlert Advance” P2RKA weatherproof horn/strobes (red, wall-mount, set to 75cd).
Initiating Devices
Pull Stations
All pull stations are Fire-Lite BG-12LX addressable dual-action pull stations.
Automatic Detection Devices
All areas of the store are protected by a wet sprinkler system with waterflow detection. There are Fire-Lite SD355 addressable photoelectric smoke detectors near the back and entrance of the store, mounted on System Sensor B210LPA low-profile bases.
Modules
There are Fire-Lite MMF-300A addressable monitor modules supervising the sprinkler system’s tamper and flow switches. There are also Fire-Lite CRF-300A addressable relay modules by each fire exit, which cause the door locks to disengage when the system goes into alarm.
System Specifications (Liquor Store)
System Specifications |
---|
FACP: Fire-Lite MS-9600UDLS FACP Location: Main Entrance Vestibule System Type: Addressable System Line Voltage: 120VAC NAC Voltage: 24VDC System Coding: Temporal Strobes Synchronized: Yes, SS Date of last known Upgrade: N/A Year Opened: 2018 |
FACP
The store is protected by a Fire-Lite MS-9600UDLS addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Fire-Lite’s LiteSpeed addressable protocol, and the system coding is temporal. This panel is likely wired to the main store’s FACP as an addressable point.
Annunciators
There is a Fire-Lite ANN-RLED annunciator below the main FACP.
Notification Appliances
There are two notification appliances in the liquor store. There is a System Sensor PC2WLA-E horn/strobe (white, ceiling-mount, set to 15cd, English lettering) and an SCWLA-E remote strobe (white, ceiling-mount, set to 15cd, English lettering).
Initiating Devices
Pull Stations
All pull stations are Fire-Lite BG-12LX addressable dual-action pull stations.
Automatic Detection Devices
All areas of the store are protected by a sprinkler system with waterflow detection. Therefore, no detectors are required by code, and none are present.
Modules
There are two Fire-Lite MMF-300A addressable monitor modules supervising the sprinkler system’s tamper and flow switches. [[]