More actions
(Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Edwards 2280 <br />FACP Location: Electrical Room <br />System Type: Conventional <br...") |
No edit summary |
||
Line 7: | Line 7: | ||
| FACP: Edwards 2280 <br />FACP Location: Electrical Room <br />System Type: Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Continuous <br />Date of last known Upgrade: 1980s <br />Year Opened: 1943 | | FACP: Edwards 2280 <br />FACP Location: Electrical Room <br />System Type: Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Continuous <br />Date of last known Upgrade: 1980s <br />Year Opened: 1943 | ||
|} | |} | ||
'''2085 Oxford Street''' is the address given to a small apartment building in Halifax, NS. It was built in 1943, and the fire alarm system was installed in the 1980s. | '''2085 Oxford Street''' is the address given to a small apartment building in Halifax, NS. It was built in 1943, and the fire alarm system was installed in the 1980s. | ||
== System Specifications (1980s-present) == | == System Specifications (1980s-present) == | ||
==== FACP ==== | ==== FACP ==== | ||
The building is protected by an Edwards 2280 conventional fire alarm system. The panel is located in an electrical room. The system coding is temporal. | The building is protected by an Edwards 2280 conventional fire alarm system. The panel is located in an electrical room. The system coding is temporal. | ||
==== Notification Appliances ==== | ==== Notification Appliances ==== | ||
All notification appliances are Edwards “Durabel” 6100-D vibrating bells (6” gong). | All notification appliances are Edwards “Durabel” 6100-D vibrating bells (6” gong). | ||
=== Initiating Devices === | === Initiating Devices === | ||
==== Pull Stations ==== | ==== Pull Stations ==== | ||
All pull stations are Edwards 274-111 conventional pull stations. | All pull stations are Edwards 274-111 conventional pull stations. | ||
==== Automatic Detection Devices ==== | ==== Automatic Detection Devices ==== | ||
None noticed. | None noticed. | ||
[[Category:Nova Scotia]] | |||
[[Category:Residential]] |
Revision as of 21:06, 17 May 2024
System Specifications |
---|
FACP: Edwards 2280 FACP Location: Electrical Room System Type: Conventional System Line Voltage: 120VAC NAC Voltage: 24VDC System Coding: Continuous Date of last known Upgrade: 1980s Year Opened: 1943 |
2085 Oxford Street is the address given to a small apartment building in Halifax, NS. It was built in 1943, and the fire alarm system was installed in the 1980s.
System Specifications (1980s-present)
FACP
The building is protected by an Edwards 2280 conventional fire alarm system. The panel is located in an electrical room. The system coding is temporal.
Notification Appliances
All notification appliances are Edwards “Durabel” 6100-D vibrating bells (6” gong).
Initiating Devices
Pull Stations
All pull stations are Edwards 274-111 conventional pull stations.
Automatic Detection Devices
None noticed.