Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Hudson's Bay (Southcentre): Difference between revisions

From FireAlarmPedia
mNo edit summary
mNo edit summary
Line 11: Line 11:
System Coding: Unknown<br />Date of last known Upgrade: 2006 <br />Year Opened: 1974
System Coding: Unknown<br />Date of last known Upgrade: 2006 <br />Year Opened: 1974
|}
|}
'''Hudson's Bay''' is a chain of department stores across Canada. It is owned and operated by the Hudson's Bay Company, the oldest company in North America. This particular location is located in [[Southcentre Mal], which is located in the Willow Park neighborhood of Southeast Calgary. The store opened at the same time as the mall, in 1974. The system is not original. This is the only non-Siemens system in the mall.<br> NOTE: All systems in the mall are networked to trip each other in alarm.
'''Hudson's Bay''' is a chain of department stores across Canada. It is owned and operated by the Hudson's Bay Company, the oldest company in North America. This particular location is located in [[Southcentre Mall]], which is located at 100 Anderson Rd SE, Calgary, AB. The store opened at the same time as the mall, in 1974. The system was upgraded in 2006. This is the only non-Siemens system in the mall.<br> NOTE: All systems in the mall are networked to trip each other in alarm.
==System Specifications (2006-present)==
==System Specifications (2006-present)==
====FACP====
====FACP====

Revision as of 12:27, 28 February 2024

  1. REDIRECT [[Southcentre Mal]
System Specifications
FACP: Mircom FX-2000

FACP Location: Unknown
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR

System Coding: Unknown
Date of last known Upgrade: 2006
Year Opened: 1974

Hudson's Bay is a chain of department stores across Canada. It is owned and operated by the Hudson's Bay Company, the oldest company in North America. This particular location is located in Southcentre Mall, which is located at 100 Anderson Rd SE, Calgary, AB. The store opened at the same time as the mall, in 1974. The system was upgraded in 2006. This is the only non-Siemens system in the mall.
NOTE: All systems in the mall are networked to trip each other in alarm.

System Specifications (2006-present)

FACP

The store is protected by a Mircom FX-2000 addressable fire alarm system. The panel location is unknown. The system runs Mircom’s CLIP addressable protocol, and the system coding is temporal. This panel is wired to the main mall’s panel as an addressable point, and is not networked.

Annunciators

There are Mircom RAX-LCD annunciators paired with RAX-1048TZDS annunciators at most entrances. All annunciators are in Mircom BB-1002 dual-bay annunciator cabinets.

Next to the second floor annunciator, there is a disconnected Simplex 4208 annunciator (model unknown), which is the only remaining device from the original system, but is disconnected.

Notification Appliances

Most notification appliances are Mircom BL-10B motor bells (10" gong).

There are also some Simplex 2901-9724 motor bells (10" gong) installed as deficiency replacements.

Initiating Devices

Pull Stations

All pull stations are Mircom MS-401AD addressable single-action pull stations.

Automatic Detection Devices

None noticed. There is a sprinkler system with waterflow detection.

Modules

There are Mircom MIX-M500MA addressable monitor modules supervising the sprinkler system's tamper and flow switches.

Bonus Information

Users User: TwentyThree33 and User: Alberta Fire Alarms were questioned for taking pictures of the system for this page, but were granted permission from the manager to take photos. Thank you to the management at this store for supporting Fire Alarmpedia!

Gallery

[[]