Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

NAIT Building X-South Learning Centre: Difference between revisions

From FireAlarmPedia
mNo edit summary
No edit summary
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Simplex 4100ES <br />FACP Location: Main Entrance <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 70.7VRMS (Audible) <br>24VDC (Visual) <br />System Coding: Unknown <br>Strobes Synchronized: No <br />Date of last known Upgrade: 2016 <br />Year Opened: 1996
| FACP: Simplex 4100ES <br />FACP Location: Main Entrance <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 70.7VRMS (Audible) <br>24VDC (Visual) <br />System Coding: Unknown <br>Strobes Synchronized: No <br />Date of last known Upgrade: 2023<br />Year Opened: 1996
|}
|}
The '''Northern Alberta Institute of Technology''' is a technical college/trades school located in Edmonton, Alberta, Canada. This page will cover the South Learning Centre/Shaw Theatre building, located at 10604 Princess Elizabeth Ave NW #10824, in Edmonton, Alberta, Canada. The building opened in 1996, and the fire alarm system is mostly original.
The '''Northern Alberta Institute of Technology''' is a technical college/trades school located in Edmonton, Alberta, Canada. This page will cover the South Learning Centre/Shaw Theatre building, located at 10604 Princess Elizabeth Ave NW #10824, in Edmonton, Alberta, Canada. The building opened in 1996, and the fire alarm system is mostly original, with a recent upgrade.
==System Specifications==
==System Specifications (1996-present)==
====FACP====
====FACP====
The building is protected by a Simplex 4100ES addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Simplex’s IDNet addressable protocol, and is equipped with voice evacuation. The evacuation signal is unknown at this time. <br>This panel was installed in 2016 as part of a campus-wide network upgrade, and replaced a Simplex 4100+. This panel is installed in the 4100+ cabinet.
The building is protected by a Simplex 4100ES addressable fire alarm system. The panel is located in the main entrance vestibule, and is equipped with the Color ES touchscreen interface. The system runs Simplex’s IDNet addressable protocol, and is equipped with voice evacuation. The evacuation signal is unknown at this time. <br>This panel was installed in 2023, replacing a 4100ES with in turn replaced a Simplex 4100+ in 2016. This panel is installed in the 4100+ cabinet.
====Notification Appliances====
====Notification Appliances====
The South Learning Centre has Wheelock E-9070-LS-24-CFW speaker/strobes (white, ceiling-mount, 70V, 15cd). <br>The Shaw Theatre has Simplex 2902-9711 remote speakers (red, wall-mount) mounted on Wheelock VLPS-24 strobe plates (1.5cd).
The South Learning Centre has Wheelock E-9070-LS-24-CFW speaker/strobes (white, ceiling-mount, 70V, 15cd). <br>The Shaw Theatre has Simplex 2902-9711 remote speakers (red, wall-mount) mounted on Wheelock VLPS-24 strobe plates (1.5cd).
For exterior notification, there is a Simplex 2902-9711 speaker outside the entrance.
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are Simplex 4099-9001 addressable single-action pull stations.
All pull stations are Simplex 4099-9004 addressable single-action pull stations. These replaced Simplex 4099-9001 addressable single-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
There are Simplex “TrueAlarm” 4098-9714 addressable photoelectric smoke detectors throughout the building, mounted on Simplex 4098-9792 bases. <br>There are Simplex 4098-9756 addressable photoelectric duct smoke detectors on all air handling units, with Simplex 2098-9808 remote indicators mounted on the drop ceiling below each detector.
There are Simplex “TrueAlarm” 4098-9714 addressable photoelectric smoke detectors throughout the building, mounted on Simplex 4098-9792 bases. <br>There are Simplex 4098-9756 addressable photoelectric duct smoke detectors on all air handling units, with Simplex 2098-9808 remote indicators mounted on the drop ceiling below each detector.
====Modules====
====Modules====
There are Simplex 4090-9001 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
There are Simplex 4090-9001 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.

Revision as of 16:55, 10 April 2024

System Specifications
FACP: Simplex 4100ES
FACP Location: Main Entrance
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 70.7VRMS (Audible)
24VDC (Visual)
System Coding: Unknown
Strobes Synchronized: No
Date of last known Upgrade: 2023
Year Opened: 1996

The Northern Alberta Institute of Technology is a technical college/trades school located in Edmonton, Alberta, Canada. This page will cover the South Learning Centre/Shaw Theatre building, located at 10604 Princess Elizabeth Ave NW #10824, in Edmonton, Alberta, Canada. The building opened in 1996, and the fire alarm system is mostly original, with a recent upgrade.

System Specifications (1996-present)

FACP

The building is protected by a Simplex 4100ES addressable fire alarm system. The panel is located in the main entrance vestibule, and is equipped with the Color ES touchscreen interface. The system runs Simplex’s IDNet addressable protocol, and is equipped with voice evacuation. The evacuation signal is unknown at this time.
This panel was installed in 2023, replacing a 4100ES with in turn replaced a Simplex 4100+ in 2016. This panel is installed in the 4100+ cabinet.

Notification Appliances

The South Learning Centre has Wheelock E-9070-LS-24-CFW speaker/strobes (white, ceiling-mount, 70V, 15cd).
The Shaw Theatre has Simplex 2902-9711 remote speakers (red, wall-mount) mounted on Wheelock VLPS-24 strobe plates (1.5cd).

For exterior notification, there is a Simplex 2902-9711 speaker outside the entrance.

Initiating Devices

Pull Stations

All pull stations are Simplex 4099-9004 addressable single-action pull stations. These replaced Simplex 4099-9001 addressable single-action pull stations.

Automatic Detection Devices

There are Simplex “TrueAlarm” 4098-9714 addressable photoelectric smoke detectors throughout the building, mounted on Simplex 4098-9792 bases.
There are Simplex 4098-9756 addressable photoelectric duct smoke detectors on all air handling units, with Simplex 2098-9808 remote indicators mounted on the drop ceiling below each detector.

Modules

There are Simplex 4090-9001 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.