| FACP: Mircom FX-2000 <br />FACP Location: Main Entrance <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, SS <br />Date of last known Upgrade: 2024 <br />Year Opened: 1954 | | FACP: Mircom FX-2000 <br />FACP Location: Main Entrance <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, SS <br />Date of last known Upgrade: 2024 <br />Year Opened: 1954 | ||
|} | |} | ||
'''Beltline Aquatic & Fitness Centre''' (also known as '''Beltline Community Hub''' prior to closure) is a closed recreation facility located at 223 12 Ave SW. It featured an indoor swimming pool, gymnasium, weight room and a climbing wall, etc. The facility opened in 1954, and the fire alarm system was upgraded in 2014. The facility has been closed since October 2022, but had a panel upgrade recently. | '''Beltline Aquatic & Fitness Centre''' (also known as '''Beltline Community Hub''' prior to closure) is a closed recreation facility located at 223 12 Ave SW. It featured an indoor swimming pool, gymnasium, weight room and a climbing wall, etc. The facility opened in 1954, and the fire alarm system was upgraded in 2014. The facility has been closed since October 2022, but had a panel upgrade recently. | ||
== System Specifications (2014-present) == | == System Specifications (2014-present) == | ||
==== FACP ==== | ==== FACP ==== | ||
The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main entrance. The system runs Mircom’s Advanced addressable protocol, and the system coding is temporal. <br> This FX-2000 was installed in 2024, as an emergency replacement for the variant installed during the 2014 upgrade. | The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main entrance. The system runs Mircom’s Advanced addressable protocol, and the system coding is temporal. <br> This FX-2000 was installed in 2024, as an emergency replacement for the variant installed during the 2014 upgrade. | ||
==== Notification Appliances ==== | ==== Notification Appliances ==== | ||
Most notification appliances are from System Sensor’s “SpectrAlert Advance” line of products. <br> Most notification appliances are System Sensor PC2WA horn/strobes (white, ceiling-mount, set to 15cd). <br> The pool area and mechanical rooms have System Sensor P2RA-B horn/strobes (red, wall-mount, bilingual lettering, set to 15cd) <br> There is a System Sensor “L-Series” PC2WLA horn/strobe (white, ceiling-mount, set to 15cd) in the mens’ locker room as a deficiency replacement. | Most notification appliances are from System Sensor’s “SpectrAlert Advance” line of products. <br> Most notification appliances are System Sensor PC2WA horn/strobes (white, ceiling-mount, set to 15cd). <br> The pool area and mechanical rooms have System Sensor P2RA-B horn/strobes (red, wall-mount, bilingual lettering, set to 15cd) <br> There is a System Sensor “L-Series” PC2WLA horn/strobe (white, ceiling-mount, set to 15cd) in the mens’ locker room as a deficiency replacement. | ||
=== Initiating Devices === | === Initiating Devices === | ||
==== Pull Stations ==== | ==== Pull Stations ==== | ||
All pull stations are Mircom MS-401AP addressable single-action pull stations. | All pull stations are Mircom MS-401AP addressable single-action pull stations. | ||
==== Automatic Detection Devices ==== | ==== Automatic Detection Devices ==== | ||
There are Mircom MIX-5251RAPA addressable fixed-temperature/rate-of-rise heat detectors throughout the building. <br> The top of each stairwell has a Mircom MIX-2251APA addressable photoelectric smoke detector. <br> All detectors are mounted on System Sensor B210LPA bases. | There are Mircom MIX-5251RAPA addressable fixed-temperature/rate-of-rise heat detectors throughout the building. <br> The top of each stairwell has a Mircom MIX-2251APA addressable photoelectric smoke detector. <br> All detectors are mounted on System Sensor B210LPA bases. | ||
==== Modules ==== | ==== Modules ==== | ||
There is a System Sensor MDL3WA synchronization module on the NAC to sync all horns and strobes. | There is a System Sensor MDL3WA synchronization module on the NAC to sync all horns and strobes. | ||
[[Category:Calgary]] | |||
[[Category:Swimming Pools]] |
Revision as of 16:44, 22 May 2024
System Specifications |
---|
FACP: Mircom FX-2000 FACP Location: Main Entrance System Type: Addressable System Line Voltage: 120VAC NAC Voltage: 24VFWR System Coding: Temporal Strobes Synchronized: Yes, SS Date of last known Upgrade: 2024 Year Opened: 1954 |
Beltline Aquatic & Fitness Centre (also known as Beltline Community Hub prior to closure) is a closed recreation facility located at 223 12 Ave SW. It featured an indoor swimming pool, gymnasium, weight room and a climbing wall, etc. The facility opened in 1954, and the fire alarm system was upgraded in 2014. The facility has been closed since October 2022, but had a panel upgrade recently.
System Specifications (2014-present)
FACP
The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main entrance. The system runs Mircom’s Advanced addressable protocol, and the system coding is temporal.
This FX-2000 was installed in 2024, as an emergency replacement for the variant installed during the 2014 upgrade.
Notification Appliances
Most notification appliances are from System Sensor’s “SpectrAlert Advance” line of products.
Most notification appliances are System Sensor PC2WA horn/strobes (white, ceiling-mount, set to 15cd).
The pool area and mechanical rooms have System Sensor P2RA-B horn/strobes (red, wall-mount, bilingual lettering, set to 15cd)
There is a System Sensor “L-Series” PC2WLA horn/strobe (white, ceiling-mount, set to 15cd) in the mens’ locker room as a deficiency replacement.
Initiating Devices
Pull Stations
All pull stations are Mircom MS-401AP addressable single-action pull stations.
Automatic Detection Devices
There are Mircom MIX-5251RAPA addressable fixed-temperature/rate-of-rise heat detectors throughout the building.
The top of each stairwell has a Mircom MIX-2251APA addressable photoelectric smoke detector.
All detectors are mounted on System Sensor B210LPA bases.
Modules
There is a System Sensor MDL3WA synchronization module on the NAC to sync all horns and strobes.