Grand Theatre (London): Difference between revisions

From FireAlarmPedia
(Added new system! Confirmed previous bell size.)
No edit summary
Line 8: Line 8:
|}
|}
The '''Grand Theatre''' is a professional theatre located at 471 Richmond St, London, Ontario. It consists of two auditoriums that run from May to September; the main auditorium has a capacity of 839. The theatre was originally built in 1901, and was reconstructed in 1978. It was then renovated in 2020, and the fire alarm system was upgraded..
The '''Grand Theatre''' is a professional theatre located at 471 Richmond St, London, Ontario. It consists of two auditoriums that run from May to September; the main auditorium has a capacity of 839. The theatre was originally built in 1901, and was reconstructed in 1978. It was then renovated in 2020, and the fire alarm system was upgraded..
== System Specifications (2020-present) ==
== System Specifications (2020-present) ==
==== FACP ====
==== FACP ====
The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel location is unknown. The system runs Mircom's Advanced addressable protocol, and is configured for two-stage operation.
The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel location is unknown. The system runs Mircom's Advanced addressable protocol, and is configured for two-stage operation.
==== Notification Appliances ====
==== Notification Appliances ====
All notification appliances are System Sensor "L-Series" P2WLA horn/strobes (white, wall-mount, bilingual lettering, set to 15cd).
All notification appliances are System Sensor "L-Series" P2WLA horn/strobes (white, wall-mount, bilingual lettering, set to 15cd).
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
All pull stations are Mircom MS-402AP addressable two-stage pull stations.
All pull stations are Mircom MS-402AP addressable two-stage pull stations.
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
None noticed. The building has a sprinkler system.
None noticed. The building has a sprinkler system.
==== Modules ====
==== Modules ====
There are Mircom MIX-M500MAPA addressable monitor modules supervising the sprinkler system's tamper and flow switches. <br> There are Mircom MIX-M500RAPA addressable relays serving various purposes.  
There are Mircom MIX-M500MAPA addressable monitor modules supervising the sprinkler system's tamper and flow switches. <br> There are Mircom MIX-M500RAPA addressable relays serving various purposes.  
== Former System Specifications (1978-2020) ==
== Former System Specifications (1978-2020) ==
{| style="float:right;border:2px solid black"
{| style="float:right;border:2px solid black"
Line 40: Line 29:
| FACP: Mircom Series 1000 <br />FACP Location: Unknown <br />System Type: Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: 20BPM (alert) <br> 120BPM march time (alarm) <br />Date of last known Upgrade: 2000s <br/> Year Installed: 1978 <br />Year Decommissioned: 2020
| FACP: Mircom Series 1000 <br />FACP Location: Unknown <br />System Type: Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: 20BPM (alert) <br> 120BPM march time (alarm) <br />Date of last known Upgrade: 2000s <br/> Year Installed: 1978 <br />Year Decommissioned: 2020
|}
|}
==== FACP ====
==== FACP ====
The building was protected by a Mircom Series 1000 conventional fire alarm system. The panel location was unknown. The system was configured for two-stage operation. The alert signal coding was 20BPM, followed by 120BPM march time as the alarm signal.
The building was protected by a Mircom Series 1000 conventional fire alarm system. The panel location was unknown. The system was configured for two-stage operation. The alert signal coding was 20BPM, followed by 120BPM march time as the alarm signal.


The Series 1000 replaced an Edwards Custom 6500 in the 2000s.
The Series 1000 replaced an Edwards Custom 6500 in the 2000s.
==== Notification Appliances ====
==== Notification Appliances ====
All notification appliances were Edwards “Adaptabel” 333D single-stroke bells (6” gong).
All notification appliances were Edwards “Adaptabel” 333D single-stroke bells (6” gong).
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
All pull stations were Edwards 270-GAO conventional two-stage pull stations.
All pull stations were Edwards 270-GAO conventional two-stage pull stations.
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
None noticed. The building had a sprinkler system.
None noticed. The building had a sprinkler system.
[[Category:Ontario]]
[[Category:Theatres]]

Revision as of 16:39, 25 May 2024

System Specifications
FACP: Mircom FX-2000
FACP Location: Unknown
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: 20BPM (Alert)
Temporal (alarm)
Date of last known Upgrade: 2021
Year Opened: 1901

The Grand Theatre is a professional theatre located at 471 Richmond St, London, Ontario. It consists of two auditoriums that run from May to September; the main auditorium has a capacity of 839. The theatre was originally built in 1901, and was reconstructed in 1978. It was then renovated in 2020, and the fire alarm system was upgraded..

System Specifications (2020-present)

FACP

The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel location is unknown. The system runs Mircom's Advanced addressable protocol, and is configured for two-stage operation.

Notification Appliances

All notification appliances are System Sensor "L-Series" P2WLA horn/strobes (white, wall-mount, bilingual lettering, set to 15cd).

Initiating Devices

Pull Stations

All pull stations are Mircom MS-402AP addressable two-stage pull stations.

Automatic Detection Devices

None noticed. The building has a sprinkler system.

Modules

There are Mircom MIX-M500MAPA addressable monitor modules supervising the sprinkler system's tamper and flow switches.
There are Mircom MIX-M500RAPA addressable relays serving various purposes.

Former System Specifications (1978-2020)

Former System Specifications
FACP: Mircom Series 1000
FACP Location: Unknown
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: 20BPM (alert)
120BPM march time (alarm)
Date of last known Upgrade: 2000s
Year Installed: 1978
Year Decommissioned: 2020

FACP

The building was protected by a Mircom Series 1000 conventional fire alarm system. The panel location was unknown. The system was configured for two-stage operation. The alert signal coding was 20BPM, followed by 120BPM march time as the alarm signal.

The Series 1000 replaced an Edwards Custom 6500 in the 2000s.

Notification Appliances

All notification appliances were Edwards “Adaptabel” 333D single-stroke bells (6” gong).

Initiating Devices

Pull Stations

All pull stations were Edwards 270-GAO conventional two-stage pull stations.

Automatic Detection Devices

None noticed. The building had a sprinkler system.