System Specifications
FACP: Grinnell Series M-1000
FACP Location: Unknown
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Continuous
Strobes Synchronized: No
Date of last known Upgrade: 2000s
Year Opened: 1995

The Home Depot is a chain of hardware store. This store is located at 6500 Macleod Trail SW, Calgary, AB. The store opened in 1995, and most of the system appears to be original.

System Specifications

FACP

The store is protected by a Grinnell Series M-1000 conventional fire alarm system. The panel location is unknown; the model is evident by the annunciator. The system coding is likely continuous.
The Series M-1000 replaced an EST 6616 in the 2000s.

Annunciators

There is a Mircom RA-1000 LED annunciator at the entrance. The main unit is model Mircom RAM-1032TZDS in a Mircom BB-1001D one-bay cabinet.

Notification Appliances

Most audible notification appliances but one are the original Edwards 439D-10AWC vibrating bells (10" gong), found throughout the store.
There is one Wheelock MB-G10-24 motor bell (10" gong) near the back of the store as a deficiency replacement.
There are also EST 202-5A-001 remote strobes (red, wall-mount, 15cd) scattered throughout the store on the ceiling.

Initiating Devices

Pull Stations

All of the pull stations are Edwards 270-SPO conventional pull stations.

Automatic Detection Devices

None noticed. There is a sprinkler system.