Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

The Home Depot (MacLeod): Difference between revisions

From FireAlarmPedia
mNo edit summary
No edit summary
Line 21: Line 21:
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
None noticed. There is a sprinkler system.
None noticed. There is a sprinkler system.
[[Category:Calgary]]
[[Category:Retail Stores]]

Revision as of 20:47, 27 May 2024

System Specifications
FACP: Grinnell Series M-1000
FACP Location: Unknown
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Continuous
Strobes Synchronized: No
Date of last known Upgrade: 2000s
Year Opened: 1995

The Home Depot is a chain of hardware store. This store is located at 6500 Macleod Trail SW, Calgary, AB. The store opened in 1995, and most of the system appears to be original.

System Specifications

FACP

The store is protected by a Grinnell Series M-1000 conventional fire alarm system. The panel location is unknown; the model is evident by the annunciator. The system coding is likely continuous.
The Series M-1000 replaced an EST 6616 in the 2000s.

Annunciators

There is a Mircom RA-1000 LED annunciator at the entrance. The main unit is model Mircom RAM-1032TZDS in a Mircom BB-1001D one-bay cabinet.

Notification Appliances

Most audible notification appliances but one are the original Edwards 439D-10AWC vibrating bells (10" gong), found throughout the store.
There is one Wheelock MB-G10-24 motor bell (10" gong) near the back of the store as a deficiency replacement.
There are also EST 202-5A-001 remote strobes (red, wall-mount, 15cd) scattered throughout the store on the ceiling.

Initiating Devices

Pull Stations

All of the pull stations are Edwards 270-SPO conventional pull stations.

Automatic Detection Devices

None noticed. There is a sprinkler system.