| FACP: Vigilant VS2 <br />FACP Location: After Entrance <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, EST self-sync <br />Date of last known Upgrade: N/A <br />Year Opened: 2015
| FACP: Vigilant VS2 <br />FACP Location: After Entrance <br />System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Genesis <br />Date of last known Upgrade: N/A <br />Year Opened: 2015
|}
|}
'''138 Lorne Ave''' is the address given to an apartment building in Winnipeg, Manitoba. It was built in 2015, and the fire alarm system is original.
'''138 Lorne Ave''' is the address given to an apartment building in Winnipeg, Manitoba. It was built in 2015, and the fire alarm system is original.
== System Specifications (2015-present) ==
== System Specifications (2015-present) ==
NOTE: This page is missing some information, and should not be used for official purposes.
==== FACP ====
==== FACP ====
The building is protected by a Vigilant VS2 addressable fire alarm system. The panel is located after the entrance. The system runs Vigilant’s GSA addressable protocol, and the system coding is temporal.
The building is protected by a Vigilant VS2 addressable fire alarm system. The panel is located after the entrance. The system runs Vigilant’s GSA addressable protocol, and the system coding is temporal.

Latest revision as of 11:15, 19 August 2024

System Specifications
FACP: Vigilant VS2
FACP Location: After Entrance
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Strobes Synchronized: Yes, Genesis
Date of last known Upgrade: N/A
Year Opened: 2015

138 Lorne Ave is the address given to an apartment building in Winnipeg, Manitoba. It was built in 2015, and the fire alarm system is original.

System Specifications (2015-present)[edit | edit source]

NOTE: This page is missing some information, and should not be used for official purposes.

FACP[edit | edit source]

The building is protected by a Vigilant VS2 addressable fire alarm system. The panel is located after the entrance. The system runs Vigilant’s GSA addressable protocol, and the system coding is temporal.

Booster Panels[edit | edit source]

There is an Edwards EBP6SA 6.5 amp power supply located in the electrical room.

Notification Appliances[edit | edit source]

All notification appliances are EST “Genesis” G1F-HDVM horn/strobes (white, wall-mount, FIRE lettering, set to 15cd).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Vigilant GSA-M270 addressable pull stations.

Automatic Detection Devices[edit | edit source]

None noticed.