Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

401C Spray Ave, Banff: Difference between revisions

From FireAlarmPedia
No edit summary
No edit summary
 
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Simplex 4100ES <br />FACP Location: Unknown <br />System Type: Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Continuous? <br />Date of last known Upgrade: 2010s <br />Year Opened: 1988
| FACP: Simplex 4100ES <br />FACP Location: Unknown <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Continuous? <br />Date of last known Upgrade: 2010s <br />Year Opened: 1988
|}
|}
'''401C Spray Ave''' is the address given to a residence near Banff Springs Hotel, Banff, AB. It is also known as the Cascade Building and also houses the Banff Springs Staff Accommodation and Recruitment Office. It was built in 1988, and the fire alarm system is mostly original.
'''401C Spray Ave''' is the address given to a residence near Banff Springs Hotel, Banff, AB. It is also known as the Cascade Building and also houses the Banff Springs Staff Accommodation and Recruitment Office. It was built in 1988, and the fire alarm system is mostly original.

Latest revision as of 16:13, 19 August 2024

System Specifications
FACP: Simplex 4100ES
FACP Location: Unknown
System Type: Single-Stage Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Continuous?
Date of last known Upgrade: 2010s
Year Opened: 1988

401C Spray Ave is the address given to a residence near Banff Springs Hotel, Banff, AB. It is also known as the Cascade Building and also houses the Banff Springs Staff Accommodation and Recruitment Office. It was built in 1988, and the fire alarm system is mostly original.

System Specifications (1988-present)[edit | edit source]

FACP[edit | edit source]

The building is protected by a Simplex 4100ES conventional fire alarm system. The panel location is unknown. The system coding is continuous.
The 4100ES replaced an Edwards Custom 6500.

Annunciators[edit | edit source]

There is a Simplex 4603-9101 LCD annunciator near the entrance.
It is right next to an Edwards annunciator, model to be confirmed that is now tinted and disconnected.

Notification Appliances[edit | edit source]

All notification appliances are Edwards 439D-6AWC vibrating bells (6” gong).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Edwards 275-C111 conventional single-action pull stations.

Automatic Detection Devices[edit | edit source]

There are System Sensor “i3” C2W-BA conventional photoelectric smoke detectors throughout the building.