RONA+ (Signal Hill): Difference between revisions

From FireAlarmPedia
No edit summary
No edit summary
 
Line 6: Line 6:
|-
|-
| FACP: Mircom FX-2000
| FACP: Mircom FX-2000
FACP Location: East Entrance Vestibule<br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage:24VFWR
FACP Location: East Entrance Vestibule<br />System Type: Single-Stage Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage:24VFWR
<br /> System Coding: Temporal <br /> Strobes Synchronized: Yes, Wheelock Sync<br />Date of last known Upgrade: 2016<br />Year Opened: 1997
<br /> System Coding: Temporal <br /> Strobes Synchronized: Yes, Wheelock Sync<br />Date of last known Upgrade: 2016<br />Year Opened: 1997
|}
|}
Line 12: Line 12:
== System Specifications ==
== System Specifications ==
==== FACP ====
==== FACP ====
The fire alarm panel is a Mircom FX-2000. The panel iis located at the east entrance. The system runs Mircom's CLIP addressable protocol, and the system coding is temporal.  
The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located at the east entrance. The system runs Mircom's CLIP addressable protocol, and the system coding is temporal.  
==== Notification Appliances ====
==== Notification Appliances ====
All of the notification appliances consist of Wheelock "Exceder" HSRC (red, ceiling mount) horn/strobes.  
All of the notification appliances consist of Wheelock "Exceder" HSRC (red, ceiling mount) horn/strobes.  
Line 22: Line 22:
==== Modules ====
==== Modules ====
There are Mircom MIX-M501MA addressable monitor modules supervising the sprinkler system's tamper and flow switches.
There are Mircom MIX-M501MA addressable monitor modules supervising the sprinkler system's tamper and flow switches.
==== EOLs ====
There are Mircom MP-300 end-of-line resistor plates on all sprinkler and signal circuits.
[[Category:Facilities]]
[[Category:Facilities]]
[[Category:Calgary]]
[[Category:Calgary]]
[[Category:Retail Stores]]
[[Category:Retail Stores]]

Latest revision as of 22:50, 9 October 2024

System Specifications
FACP: Mircom FX-2000

FACP Location: East Entrance Vestibule
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage:24VFWR
System Coding: Temporal
Strobes Synchronized: Yes, Wheelock Sync
Date of last known Upgrade: 2016
Year Opened: 1997

RONA+ is a chain of hardware stores. This location is located at 5696 Signal Hill Centre SW, Calgary, AB. It was built in 1997 as a Zellers, then it was converted to a Target in 2012, and finally a Lowe's in 2016. The fire alarm system was installed following the Lowe's conversion.

System Specifications[edit | edit source]

FACP[edit | edit source]

The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located at the east entrance. The system runs Mircom's CLIP addressable protocol, and the system coding is temporal.

Notification Appliances[edit | edit source]

All of the notification appliances consist of Wheelock "Exceder" HSRC (red, ceiling mount) horn/strobes.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

The pull stations consist of Mircom MS-401AD addressable pull stations.

Automatic Detection Devices[edit | edit source]

The storefront is protected by waterflow, therefore there are no detectors.

Modules[edit | edit source]

There are Mircom MIX-M501MA addressable monitor modules supervising the sprinkler system's tamper and flow switches.

EOLs[edit | edit source]

There are Mircom MP-300 end-of-line resistor plates on all sprinkler and signal circuits.