Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Walmart Supercentre (Cochrane): Difference between revisions

From FireAlarmPedia
No edit summary
No edit summary
 
Line 5: Line 5:
|  
|  
|-
|-
| FACP: EST QuickStart QS1 or iO64 <br /> FACP Location: Not visible <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br /> System Coding: Temporal <br> Strobes Synchronized: Yes <br />Date of last known Upgrade: N/A <br />Year Opened: 2014
| FACP: EST iO500<br /> FACP Location: Main Entrance Vestibule<br />System Type: Single-Stage Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br /> System Coding: Temporal <br> Strobes Synchronized: Yes <br />Date of last known Upgrade: N/A <br />Year Opened: 2014
|}
|}


Line 12: Line 12:
== System Specifications ==
== System Specifications ==
==== FACP ====
==== FACP ====
The store is protected by either an EST QuickStart QS1 or iO64 addressable fire alarm system. The panel is not visible, but was is assumed. There are no visible annunciators. The system runs EST's Signature-series addressable protocol, and the system coding is Temporal.
The store is protected by either an EST iO500 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs EST's Signature-series addressable protocol, and the system coding is Temporal.
==== Notification Appliances ====
==== Notification Appliances ====
The notification appliances are EST "Genesis" G1R-HDVM (red, wall, no FIRE) horn/strobes, and EST "Genesis" G1-VM (red, wall, no FIRE) remote strobes. On pillars, there are two horn/strobes on two opposite sides, and the other two have remote strobes.  
The notification appliances are EST "Genesis" G1R-HDVM (red, wall, no FIRE) horn/strobes, and EST "Genesis" G1-VM (red, wall, no FIRE) remote strobes. On pillars, there are two horn/strobes on two opposite sides, and the other two have remote strobes.  
Line 20: Line 20:
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
Waterflow detection, no visible detectors.
Waterflow detection, no visible detectors.
==== Modules ====
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.
==== EOLs ====
There are Edwards EOL-P1 end-of-line resistor plates on all sprinkler and signal circuits.
[[Category:Facilities]]
[[Category:Facilities]]
[[Category:Retail Stores]]
[[Category:Retail Stores]]
[[Category:Cochrane]]
[[Category:Cochrane]]

Latest revision as of 20:12, 14 October 2024

System Specifications
FACP: EST iO500
FACP Location: Main Entrance Vestibule
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Strobes Synchronized: Yes
Date of last known Upgrade: N/A
Year Opened: 2014


Walmart is a retail outlet chain. This particular location is located at 15 Quarry Street in the town of Cochrane, Alberta. It was built in 2014, and has the original fire alarm system.

System Specifications[edit | edit source]

FACP[edit | edit source]

The store is protected by either an EST iO500 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs EST's Signature-series addressable protocol, and the system coding is Temporal.

Notification Appliances[edit | edit source]

The notification appliances are EST "Genesis" G1R-HDVM (red, wall, no FIRE) horn/strobes, and EST "Genesis" G1-VM (red, wall, no FIRE) remote strobes. On pillars, there are two horn/strobes on two opposite sides, and the other two have remote strobes.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

The pull stations are EST SIGA-270 addressable single-action pull stations.

Automatic Detection Devices[edit | edit source]

Waterflow detection, no visible detectors.

Modules[edit | edit source]

There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.

EOLs[edit | edit source]

There are Edwards EOL-P1 end-of-line resistor plates on all sprinkler and signal circuits.