Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Weld Central Middle School: Difference between revisions

From FireAlarmPedia
mNo edit summary
 
Line 35: Line 35:
The smoke detectors are Fire-Lite SD-355 Photoelectric Smoke Detectors, mounted on System Sensor B710LP bases.  
The smoke detectors are Fire-Lite SD-355 Photoelectric Smoke Detectors, mounted on System Sensor B710LP bases.  
==System Specifications (1963-2006)==
==System Specifications (1963-2006)==
{| style="float:right;border:2px solid black"
|-
! Former System Specifications
|-
|
|-
| FACP: Simplex 4247 <br />FACP Location: Unknown <br />System Type: Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 6VAC <br />System Coding: Continuous <br />Date of last known Upgrade: N/A <br/> Year Installed: 1963 <br />Year Decommissioned: 2006
|}
===FACP===
===FACP===
The building was protected by a Simplex 4247 conventional fire alarm system. The panel location was unknown. The system coding was likely continuous.
The building was protected by a Simplex 4247 conventional fire alarm system. The panel location was unknown. The system coding was likely continuous.
Line 41: Line 50:
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations were Simplex 4251-1 Conventional Non-coded pull stations.
All pull stations were Simplex 4251-1 conventional single-action pull stations.
[[Category:Schools]]
[[Category:Schools]]
[[Category:Colorado]]
[[Category:Colorado]]

Latest revision as of 18:09, 2 August 2024

System Specifications
FACP: FireLite MS-9600

FACP Location: Unknown
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Strobes Synchronized Yes, System Sensor
Date of last known Upgrade: 2006
Year Opened: 1963

Weld Central Middle School is a public Middle School ran by Weld County School District 3J and this building is located at 4977 Co Rd 59, Keenesburg, Colorado. The school opened in 1963, and the fire alarm system was upgraded around 2007.

System Specifications (2007-Present)[edit | edit source]

Please note that some of these specifications may not be accurate. This page should not be used for official purposes.

FACP[edit | edit source]

The building is protected by a FireLite MS-9600 addressable fire alarm system. The panel is location is unknown. The system runs Fire-Lite's CLIP addressable protocol, and the system coding is temporal.

Notification Appliances[edit | edit source]

All notification appliances are System Sensor "SpectrAlert Advance" P2R horn/strobes (red, wall-mount, set to 75cd) and System Sensor "SpectrAlert Advance" SR remote strobes (red, wall-mount, set to 15cd).

The classrooms have System Sensor "SpectrAlert Advance" PC2R Horn/Strobes (red, ceiling-mount, set on 75cd) and System Sensor "SpectrAlert Advance" SCR remote strobes (Red, Ceiling-Mount, set on 75cd).

The office has System Sensor "SpectrAlert" P1224MC Horn Strobes (red, wall-mount, set on 75cd).

The library and cafeteria have System Sensor "SpectrAlert" PC2475 Horn Strobes (Red, Ceiling-Mount, 75cd).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Fire-Lite BG-12LX Dual Action Addressable pull stations.

Automatic Detection Devices[edit | edit source]

The smoke detectors are Fire-Lite SD-355 Photoelectric Smoke Detectors, mounted on System Sensor B710LP bases.

System Specifications (1963-2006)[edit | edit source]

Former System Specifications
FACP: Simplex 4247
FACP Location: Unknown
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 6VAC
System Coding: Continuous
Date of last known Upgrade: N/A
Year Installed: 1963
Year Decommissioned: 2006

FACP[edit | edit source]

The building was protected by a Simplex 4247 conventional fire alarm system. The panel location was unknown. The system coding was likely continuous.

Notification Appliances[edit | edit source]

All notification appliances were Simplex 4030 vibratory horns (red, dual-projector).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations were Simplex 4251-1 conventional single-action pull stations.