Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

1611 36 Ave SW, Calgary: Difference between revisions

From FireAlarmPedia
No edit summary
No edit summary
 
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Edwards 1527 <br />FACP Location: Unknown <br />System Type: Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Continuous <br />Date of last known Upgrade: Late 1980s <br />Year Opened: 1957
| FACP: Edwards 1527 <br />FACP Location: Unknown <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Continuous <br />Date of last known Upgrade: Late 1980s <br />Year Opened: 1957
|}
|}
'''1611 36 Ave SW''' is the address given to a walk-up apartment building in Calgary, AB. It was built in 1957, and the fire alarm system was upgraded in the late 1980s.
'''1611 36 Ave SW''' is the address given to a walk-up apartment building in Calgary, AB. It was built in 1957, and the fire alarm system was upgraded in the late 1980s.
Line 18: Line 18:
All pull stations are Edwards 275-C111 conventional single-action pull stations.
All pull stations are Edwards 275-C111 conventional single-action pull stations.
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
None noticed
None noticed.
 
==== EOLs ====
There are Edwards EOL-P1 end of line resistor plates on all circuits.
[[Category:Calgary]]
[[Category:Calgary]]
[[Category:Residential]]
[[Category:Residential]]

Latest revision as of 11:52, 19 August 2024

System Specifications
FACP: Edwards 1527
FACP Location: Unknown
System Type: Single-Stage Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Continuous
Date of last known Upgrade: Late 1980s
Year Opened: 1957

1611 36 Ave SW is the address given to a walk-up apartment building in Calgary, AB. It was built in 1957, and the fire alarm system was upgraded in the late 1980s.

System Specifications (late 1980s-present)[edit | edit source]

  • Please note that some system details are unconfirmed. This page should not be used for official purposes.

FACP[edit | edit source]

The building is protected by an Edwards 1527 conventional fire alarm system. The panel location is unknown, and it is unknown if it was replaced. The system coding is continuous.

Notification Appliances[edit | edit source]

All notification appliances are Edwards “Durabel” 6100D vibrating bells (6” gong).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Edwards 275-C111 conventional single-action pull stations.

Automatic Detection Devices[edit | edit source]

None noticed.

EOLs[edit | edit source]

There are Edwards EOL-P1 end of line resistor plates on all circuits.