Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Boston Pizza (Memorial): Difference between revisions

From FireAlarmPedia
No edit summary
No edit summary
 
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Simplex 4007ES <br>FACP Location: Main Entrance<br />System Type: Conventional<br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br>System Coding: Temporal? <br>Strobes Synchronized: Yes<br />Date of last known Upgrade: 2020 <br />Year Opened: 1978
| FACP: Simplex 4007ES <br>FACP Location: Main Entrance Vestibule<br />System Type: Single-Stage Conventional<br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br>System Coding: Temporal? <br>Strobes Synchronized: Yes<br />Date of last known Upgrade: 2020 <br />Year Opened: 1978
|}
|}
'''Boston Pizza''' is Canada's largest chain of casual dining restaurants. This particular restaurant is located at 2836 Memorial Drive, in Calgary, Alberta, Canada. The building opened in 1978. Most of the fire alarm system is from the 2000s.
'''Boston Pizza''' is Canada's largest chain of casual dining restaurants. This particular restaurant is located at 2836 Memorial Drive, in Calgary, Alberta, Canada. The building opened in 1978. Most of the fire alarm system is from the 2000s.
Line 22: Line 22:
====Automatic Detection Devices====
====Automatic Detection Devices====
None noticed.
None noticed.
==== EOLs ====
There are Edwards EOL-P1 end of line resistor plates on all circuits.
=== Bonus Information ===
=== Bonus Information ===
Permit issued for FACP upgrade on August 14th, 2020. Permit description: Fire alarm panel replacement at Memorial Boston Pizza. (Source: Calgary MyProperty)
Permit issued for FACP upgrade on August 14th, 2020. Permit description: Fire alarm panel replacement at Memorial Boston Pizza. (Source: Calgary MyProperty)

Latest revision as of 15:49, 8 September 2024

System Specifications
FACP: Simplex 4007ES
FACP Location: Main Entrance Vestibule
System Type: Single-Stage Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal?
Strobes Synchronized: Yes
Date of last known Upgrade: 2020
Year Opened: 1978

Boston Pizza is Canada's largest chain of casual dining restaurants. This particular restaurant is located at 2836 Memorial Drive, in Calgary, Alberta, Canada. The building opened in 1978. Most of the fire alarm system is from the 2000s.

System Specifications (2000s-present)[edit | edit source]

FACP[edit | edit source]

The building is protected by a Simplex 4007ES conventional fire alarm system. The panel is located in the main entrance vestibule, and was installed in 2020. The system coding is likely temporal.

The 4007ES likely replaced an EST FireShield FS502G.

Notification Appliances[edit | edit source]

All notification appliances but one are Edwards 439D-6AWC vibrating bells (6" gong) mounted on Edwards 403-5A-R strobe plates (15cd).

The party room has a General Signal MB6-24 motor bell (6" gong) mounted on an Edwards 403-5A-R strobe plate (15cd).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

The only known pull station is a Mircom MS-401 conventional single-action pull station. The other pull stations are unknown at this time.

Automatic Detection Devices[edit | edit source]

None noticed.

EOLs[edit | edit source]

There are Edwards EOL-P1 end of line resistor plates on all circuits.

Bonus Information[edit | edit source]

Permit issued for FACP upgrade on August 14th, 2020. Permit description: Fire alarm panel replacement at Memorial Boston Pizza. (Source: Calgary MyProperty) [[]