More actions
(Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FX-2000 <br />FACP Location: Behind Front Desk <br />System Type: Hybrid-Addre...") |
No edit summary |
||
Line 5: | Line 5: | ||
| | | | ||
|- | |- | ||
| FACP: Mircom FX-2000 <br />FACP Location: Behind Front Desk <br />System Type: Hybrid-Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: 2015 <br />Year Opened: 1964 | | FACP: Mircom FX-2000 <br />FACP Location: Behind Front Desk <br />System Type: Single-Stage Hybrid-Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: 2015 <br />Year Opened: 1964 | ||
|} | |} | ||
'''Holiday Inn Express''' is a chain of budget hotels owned by Intercontinental. The chain is headquartered in Denham, England, and has locations worldwide. This particular location is located at 10010 104 St NW, Edmonton, Alberta. The hotel was built in 1964, and was renovated in 2015. The fire alarm system was upgraded in 2015. | '''Holiday Inn Express''' is a chain of budget hotels owned by Intercontinental. The chain is headquartered in Denham, England, and has locations worldwide. This particular location is located at 10010 104 St NW, Edmonton, Alberta. The hotel was built in 1964, and was renovated in 2015. The fire alarm system was upgraded in 2015. | ||
== System Specifications (2015-present) == | == System Specifications (2015-present) == | ||
==== FACP ==== | ==== FACP ==== | ||
The building is protected by a Mircom FX-2000 hybrid-addressable fire alarm system. The panel is located behind the front desk. The system runs Mircom’s CLIP addressable protocol, and the system coding is temporal. | The building is protected by a Mircom FX-2000 hybrid-addressable fire alarm system. The panel is located behind the front desk. The system runs Mircom’s CLIP addressable protocol, and the system coding is temporal. | ||
==== Notification Appliances ==== | ==== Notification Appliances ==== | ||
Most notification appliances are Mircom “Select-a-Horn/Strobe” FHS-340R horn/strobes (red, wall-mount, set to electromechanical/15cd). <br> A banquet hall has Mircom “Select-a-Horn” FH-340R remote horns (red, wall-mount, set to electromechanical). | Most notification appliances are Mircom “Select-a-Horn/Strobe” FHS-340R horn/strobes (red, wall-mount, set to electromechanical/15cd). <br> A banquet hall has Mircom “Select-a-Horn” FH-340R remote horns (red, wall-mount, set to electromechanical). | ||
=== Initiating Devices === | === Initiating Devices === | ||
==== Pull Stations ==== | ==== Pull Stations ==== | ||
Most pull stations are a mix of Notifier NFM-950B and MPS-950B conventional single-action pull stations. <br> Some areas have Mircom MS-401 conventional single-action pull stations. | Most pull stations are a mix of Notifier NFM-950B and MPS-950B conventional single-action pull stations. <br> Some areas have Mircom MS-401 conventional single-action pull stations. | ||
==== Automatic Detection Devices ==== | ==== Automatic Detection Devices ==== | ||
There are Mircom MIX-2251APA addressable photoelectric smoke detectors throughout, mounted on System Sensor B210LPA bases. | There are Mircom MIX-2251APA addressable photoelectric smoke detectors throughout, mounted on System Sensor B210LPA bases. | ||
==== EOLs ==== | ==== EOLs ==== | ||
There are Mircom MP-300 end-of-line resistors on the sprinkler system and NACs. | There are Mircom MP-300 end-of-line resistors on the sprinkler system and NACs. | ||
[[Category:Edmonton]] | [[Category:Edmonton]] | ||
[[Category:Hotels]] | [[Category:Hotels]] |
Revision as of 11:13, 30 September 2024
System Specifications |
---|
FACP: Mircom FX-2000 FACP Location: Behind Front Desk System Type: Single-Stage Hybrid-Addressable System Line Voltage: 120VAC NAC Voltage: 24VFWR System Coding: Temporal Strobes Synchronized: Yes, Mircom Date of last known Upgrade: 2015 Year Opened: 1964 |
Holiday Inn Express is a chain of budget hotels owned by Intercontinental. The chain is headquartered in Denham, England, and has locations worldwide. This particular location is located at 10010 104 St NW, Edmonton, Alberta. The hotel was built in 1964, and was renovated in 2015. The fire alarm system was upgraded in 2015.
System Specifications (2015-present)
FACP
The building is protected by a Mircom FX-2000 hybrid-addressable fire alarm system. The panel is located behind the front desk. The system runs Mircom’s CLIP addressable protocol, and the system coding is temporal.
Notification Appliances
Most notification appliances are Mircom “Select-a-Horn/Strobe” FHS-340R horn/strobes (red, wall-mount, set to electromechanical/15cd).
A banquet hall has Mircom “Select-a-Horn” FH-340R remote horns (red, wall-mount, set to electromechanical).
Initiating Devices
Pull Stations
Most pull stations are a mix of Notifier NFM-950B and MPS-950B conventional single-action pull stations.
Some areas have Mircom MS-401 conventional single-action pull stations.
Automatic Detection Devices
There are Mircom MIX-2251APA addressable photoelectric smoke detectors throughout, mounted on System Sensor B210LPA bases.
EOLs
There are Mircom MP-300 end-of-line resistors on the sprinkler system and NACs.