More actions
No edit summary |
No edit summary |
||
Line 5: | Line 5: | ||
| | | | ||
|- | |- | ||
| FACP: EST QuickStart QS4 (unconfirmed) <br /> FACP Location: Unknown <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br /> System Coding: Temporal <br> Strobes Synchronized: Yes, EST<br />Date of last known Upgrade: N/A <br />Year Opened: 2006 | | FACP: EST QuickStart QS4 (unconfirmed) <br /> FACP Location: Unknown <br />System Type: Single-Stage Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br /> System Coding: Temporal <br> Strobes Synchronized: Yes, EST<br />Date of last known Upgrade: N/A <br />Year Opened: 2006 | ||
|} | |} | ||
'''Super 8''' is a budget hotel chain owned by Wyndham. They are headquartered in Parsippany, New Jersey, USA, and have locations worldwide. This particular hotel is located at 5220 2 Avenue, in Edson, Alberta, Canada. The hotel opened in 2006, and the fire alarm system is original. | '''Super 8''' is a budget hotel chain owned by Wyndham. They are headquartered in Parsippany, New Jersey, USA, and have locations worldwide. This particular hotel is located at 5220 2 Avenue, in Edson, Alberta, Canada. The hotel opened in 2006, and the fire alarm system is original. | ||
Line 25: | Line 25: | ||
===== Modules ===== | ===== Modules ===== | ||
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches. | There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches. | ||
==== EOLs ==== | |||
There are Edwards EOL-P1 end-of-line resistor plates on all sprinkler and signal circuits. | |||
[[Category:Facilities]] | [[Category:Facilities]] | ||
[[Category:Hotels]] | [[Category:Hotels]] | ||
[[Category:Edson]] | [[Category:Edson]] |
Latest revision as of 23:14, 13 October 2024
System Specifications |
---|
FACP: EST QuickStart QS4 (unconfirmed) FACP Location: Unknown System Type: Single-Stage Addressable System Line Voltage: 120VAC NAC Voltage: 24VFWR System Coding: Temporal Strobes Synchronized: Yes, EST Date of last known Upgrade: N/A Year Opened: 2006 |
Super 8 is a budget hotel chain owned by Wyndham. They are headquartered in Parsippany, New Jersey, USA, and have locations worldwide. This particular hotel is located at 5220 2 Avenue, in Edson, Alberta, Canada. The hotel opened in 2006, and the fire alarm system is original.
System Specifications (2006-present)[edit | edit source]
Please note that some system information is unknown. This page should not be used for official purposes. Fire Alarmpedia is not responsible for any issues caused by inaccuracies.
FACP[edit | edit source]
The building is protected by an EST addressable fire alarm system. The model of the panel is unknown, but is believed to be a QuickStart QS4. The system runs EST’s Signature addressable protocol, and the system coding is temporal.
Notification Appliances[edit | edit source]
All notification appliances are from EST's "Genesis" line of products.
Common Areas[edit | edit source]
All common area notification appliances are EST G1R-HDVM horn/strobes (red, wall-mount, no lettering, set to 15cd).
Guest Rooms[edit | edit source]
The guest rooms have EST G1-HDVM horn/strobes (white, wall-mount, no lettering, set to 110cd).
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
All pull stations are EST SIGA-270 addressable single-action pull stations.
Automatic Detection Devices[edit | edit source]
There are EST SIGA-PS addressable photoelectric smoke detectors throughout the hotel, mounted on SIGA-SB bases. There is also a sprinkler system with waterflow detection.
Modules[edit | edit source]
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.
EOLs[edit | edit source]
There are Edwards EOL-P1 end-of-line resistor plates on all sprinkler and signal circuits.