'''Wilma Hansen School''' is a junior high school located in the Queensland neighborhood of Southeast Calgary.  It has a capacity of 900 students, but is currently not at capacity.  It houses students in grades 7 to 9.  The school was built in 1983, but does not have the original system.
'''Wilma Hansen School''' is a junior high school located in the Queensland neighborhood of Southeast Calgary.  It has a capacity of 900 students, but is currently not at capacity.  It houses students in grades 7 to 9.  The school was built in 1983, but does not have the original fire alarm system.


==System Specifications==
==System Specifications==


====FACP====
====FACP====
The building is protected by a Notifier NFS2-640C addressable fire alarm control panel.  It was installed in 2016, following a system upgrade.  The panel is located in the main office.
The fire alarm panel is a Notifier NFS2-640C (addressable).  It was installed in 2016, following a system upgrade.  The panel is located in the main office.


=====Annunciators=====
=====Annunciators=====
Line 10: Line 10:


====Notification Appliances====
====Notification Appliances====
The notification appliances are mainly System Sensor "Spectralert Advance" P2R horn/strobes (red, wall-mount).  They are set on code 3, and the volume setting varies throughout the school.  The classrooms have System Sensor MHR mini-horns, also set on code 3.  The restrooms have System Sensor "Spectralert Advance" SR remote strobes.
The notification appliances are mainly System Sensor "SpectrAlert Advance" P2R horn/strobes (red, wall-mount, 2-wire).  They are set on code 3, and the volume setting varies throughout the school.  The classrooms have System Sensor "SpectrAlert Advance" MHR (red) mini-horns, also set on code 3.  The restrooms have System Sensor "SpectrAlert Advance" SR (red, wall) remote strobes. These were all installed in 2016 along with the panel.


===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
The pull stations are all Notifier N-MPS-SA addressable single action pull stations.
The pull stations are Notifier N-MPS-SA addressable single-action pull stations.


====Automatic Detection Devices====
====Automatic Detection Devices====
There are Notifier FSP-851 smoke detectors located throughout the school.
There are Notifier FSP-851 addressable photoelectric smoke detectors located throughout the school.

Revision as of 22:51, 2 April 2021

Wilma Hansen School is a junior high school located in the Queensland neighborhood of Southeast Calgary. It has a capacity of 900 students, but is currently not at capacity. It houses students in grades 7 to 9. The school was built in 1983, but does not have the original fire alarm system.

System Specifications

FACP

The fire alarm panel is a Notifier NFS2-640C (addressable). It was installed in 2016, following a system upgrade. The panel is located in the main office.

Annunciators

There is a Notifier KDM-R2 annunciator near the main entrance.

Notification Appliances

The notification appliances are mainly System Sensor "SpectrAlert Advance" P2R horn/strobes (red, wall-mount, 2-wire). They are set on code 3, and the volume setting varies throughout the school. The classrooms have System Sensor "SpectrAlert Advance" MHR (red) mini-horns, also set on code 3. The restrooms have System Sensor "SpectrAlert Advance" SR (red, wall) remote strobes. These were all installed in 2016 along with the panel.

Initiating Devices

Pull Stations

The pull stations are Notifier N-MPS-SA addressable single-action pull stations.

Automatic Detection Devices

There are Notifier FSP-851 addressable photoelectric smoke detectors located throughout the school.