Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Twentytwo22's Garage (Old System): Difference between revisions

From FireAlarmPedia
(Added Infobox, Updated info)
Line 1: Line 1:
[[Category:Hobby]]
[[Category:Hobby]]
 
{| style="float:right;border:2px solid black"
|-
!System Specifications
|-
|
|-
|FACP: EST Quickstart QS1<br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR
System Type: Addressable (Hybrid Manner)<br />Date of last upgrade: March 15, 2021<br />Year Built: 1966
|}
The original '''Twentytwo22's Garage''' was a small residential garage in Sundance, built in 1994. The system was owned by User:Twentytwo22
The original '''Twentytwo22's Garage''' was a small residential garage in Sundance, built in 1994. The system was owned by User:Twentytwo22
As of September 1st, 2020 Twentytwo22 has moved to a location in Glenbrook. <br> The new garage was built in 1966 and plans to add period specific Initiating Devices (except automatic detection) and Notification Appliances are considered.
As of September 1st, 2020 Twentytwo22 has moved to a location in Glenbrook. <br> The new garage was built in 1966 and plans to add period specific Initiating Devices (except automatic detection) and Notification Appliances are considered.
== System Specifications ==
==System Specifications==
 
====FACP====
==== FACP ====
 
The fire alarm panel is an EST (GE) QuickStart QS1 (addressable) from the early 2010s (circuitboard is from 2008) with the PS6 power supply card and one SLIC card. The system was upgraded from a conventional EST QuickStart QSC (made 2005) in February 2021 due to the failure of the QSC CPU and a QS1 CPU being the only replacement available. The QS1 CPU is on the QSC's cabinet.
The fire alarm panel is an EST (GE) QuickStart QS1 (addressable) from the early 2010s (circuitboard is from 2008) with the PS6 power supply card and one SLIC card. The system was upgraded from a conventional EST QuickStart QSC (made 2005) in February 2021 due to the failure of the QSC CPU and a QS1 CPU being the only replacement available. The QS1 CPU is on the QSC's cabinet.
<br> Most of the zones were unused and simply have a resistor across them due to the small size of the garage. The panel was transferred over from the old garage. The panel will be setup as a timed two-stage system.
<br>The panel was transferred over from the old garage. The panel is currently setup in a Single stage manner. When activated the bells do Code-3.
In first stage the panel will do 20bpm (slow march) and 120bpm March time in general alarm.
====Notification Appliances====
 
The notification appliances consist of an Edwards 438D-6N5C 120VAC vibrating bell (from [[7044 Ogden Road SE]]) (see below circuit) on a Wheelock RSSP-2415W strobe plate in the garage, an Edwards "Durabel" 6100D vibrating bell (6" gong, pre-1970s) and an EST "Genesis LED" G1-VRF (red, wall-mount) remote strobe in the attic. There is also 3 Wheelock "Exceder" STWC (white, ceiling-mount) remote strobes on the ground floor.
==== Notification Appliances ====
 
The notification appliances consist of an Edwards 438D-6N5C 120VAC vibrating bell (from [[7044 Ogden Road SE]]) (see below circuit) on a Wheelock RSSP-2415W strobe plate in the garage, an Edwards "Durabel" 6100D vibrating bell (6" gong, pre-1970s) and an EST "Genesis LED" G1-AVRF (red, fire marking) LED horn/strobe (horn disabled, so basically a "remote strobe") in the attic. Twentytwo22 has plans install a Notifier KMS-10-24A motor bell, and three Wheelock "Exceder" STWC (white, ceiling) remote strobes.


[[File:Ac-bell-modern-panel-circuit.png]]
[[File:Ac-bell-modern-panel-circuit.png]]
 
===Initiating Devices===
=== Initiating Devices ===
====Pull Stations====
 
Currently, there is is a Simplex 2099-9754 at the man-door. (A section of drywall directly above it was temporarily removed to aid in running wires), a vintage Edwards 270-SPO (1970s) at the overhead door, and another vintage Edwards 270-SPO (2nd Generation) is installed in the attic. (both salvaged from [[7044 Ogden Road SE]])
==== Pull Stations ====
====Automatic Detection Devices====
 
There is one automatic detection device, an ADT Rebrand of an EST SIGA-PS (ADT-PS) installed beside the door opener on the main floor.
Currently, there is is a Simplex 2099-9754 at the man-door. (A section of drywall directly above the BG-12L was temporarily removed to aid in running wires), an Edwards 274-111 at the overhead door, and a vintage Edwards 270-SPO is installed in the attic. (both salvaged from [[7044 Ogden Road SE]])
==System Specifications (Original Garage)==
 
==== Automatic Detection Devices ====
 
There is one automatic detection device, a System Sensor C4W-B (i3) smoke detector.
 
== System Specifications (Original Garage) ==
 
====FACP====
====FACP====
The fire alarm panel was an EST Quickstart QSC (conventional) with the PS6 power supply card and one ZB16 card. Most of the Zones were unused and simply have a resistor across them due to the small size of the garage. Now in use on the new garage.
The fire alarm panel was an EST Quickstart QSC (conventional) with the PS6 power supply card and one ZB16 card. Most of the Zones were unused and simply had a resistor across them due to the small size of the garage. Now in use on the new garage.
 
====Notification Appliances====
====Notification Appliances====
The two notification appliances were a Simplex 2901-9722 10" motor bell installed to accommodate owner preference and one EST Genesis G1-VM (white, no fire marking) remote strobe. The 2901-9722 was previously used in a school, and is still in use on the new garage. Formerly, there was a Gentex "Commander 3" GEC3-24WR (red, wall) horn/strobe.
The two notification appliances were a Simplex 2901-9722 10" motor bell installed to accommodate owner preference and one EST Genesis G1-VM (white, no fire marking) remote strobe. The 2901-9722 was previously used in a school, and is still in use on the new garage. Formerly, there was a Gentex "Commander 3" GEC3-24WR (red, wall) horn/strobe.
 
===Initiating Devices===
=== Initiating Devices ===
====Pull Stations====
====Pull Stations====
The pull stations consisted of one Chinese Pull Station, one Fire-Lite BG-12L and one GE-branded Edwards 270-SPO.
The pull stations consisted of one Chinese Pull Station, one Fire-Lite BG-12L and one GE-branded Edwards 270-SPO.
====Automatic Detection Devices====
====Automatic Detection Devices====
There was one automatic detection device, a System Sensor C4W-B (i3) smoke detector that replaced a two wire equivalent. (C2W-BA)
There was one automatic detection device, a System Sensor C4W-B (i3) smoke detector that replaced a two wire equivalent. (C2W-BA)
[[Category:Facilities]]
[[Category:Facilities]]
==New Garage Installation Photos==
==New Garage Installation Photos==
<gallery>
<gallery>
2222gWiring12272020.jpg|The panel as it looked on December 27th, 2020 at this point the wiring for the back pull station and the Notifier bell had not yet been run.
2222gWiring12272020.jpg|The panel as it looked on December 27th, 2020 at this point the wiring for the back pull station and the Notifier bell had not yet been run.
Line 55: Line 46:
G1-avrf.jpg|The modified "Genesis LED" G1-AVRF Horn/Strobe shortly after installation. (Note the piece of plywood required to give the extra clearance needed by the device.)
G1-avrf.jpg|The modified "Genesis LED" G1-AVRF Horn/Strobe shortly after installation. (Note the piece of plywood required to give the extra clearance needed by the device.)
</gallery>
</gallery>
==Installation Videos==
==Installation Videos==
Testing the Modified G1-AVRF "Genesis LED" horn-strobe (converted to remote strobe)  
Testing the Modified G1-AVRF "Genesis LED" horn-strobe (converted to remote strobe)
[[File:LgenesisTest.mp4]]
[[File:LgenesisTest.mp4]]

Revision as of 02:46, 4 May 2021

System Specifications
FACP: EST Quickstart QS1
System Line Voltage: 120VAC
NAC Voltage: 24VFWR

System Type: Addressable (Hybrid Manner)
Date of last upgrade: March 15, 2021
Year Built: 1966

The original Twentytwo22's Garage was a small residential garage in Sundance, built in 1994. The system was owned by User:Twentytwo22 As of September 1st, 2020 Twentytwo22 has moved to a location in Glenbrook.
The new garage was built in 1966 and plans to add period specific Initiating Devices (except automatic detection) and Notification Appliances are considered.

System Specifications

FACP

The fire alarm panel is an EST (GE) QuickStart QS1 (addressable) from the early 2010s (circuitboard is from 2008) with the PS6 power supply card and one SLIC card. The system was upgraded from a conventional EST QuickStart QSC (made 2005) in February 2021 due to the failure of the QSC CPU and a QS1 CPU being the only replacement available. The QS1 CPU is on the QSC's cabinet.
The panel was transferred over from the old garage. The panel is currently setup in a Single stage manner. When activated the bells do Code-3.

Notification Appliances

The notification appliances consist of an Edwards 438D-6N5C 120VAC vibrating bell (from 7044 Ogden Road SE) (see below circuit) on a Wheelock RSSP-2415W strobe plate in the garage, an Edwards "Durabel" 6100D vibrating bell (6" gong, pre-1970s) and an EST "Genesis LED" G1-VRF (red, wall-mount) remote strobe in the attic. There is also 3 Wheelock "Exceder" STWC (white, ceiling-mount) remote strobes on the ground floor.

Initiating Devices

Pull Stations

Currently, there is is a Simplex 2099-9754 at the man-door. (A section of drywall directly above it was temporarily removed to aid in running wires), a vintage Edwards 270-SPO (1970s) at the overhead door, and another vintage Edwards 270-SPO (2nd Generation) is installed in the attic. (both salvaged from 7044 Ogden Road SE)

Automatic Detection Devices

There is one automatic detection device, an ADT Rebrand of an EST SIGA-PS (ADT-PS) installed beside the door opener on the main floor.

System Specifications (Original Garage)

FACP

The fire alarm panel was an EST Quickstart QSC (conventional) with the PS6 power supply card and one ZB16 card. Most of the Zones were unused and simply had a resistor across them due to the small size of the garage. Now in use on the new garage.

Notification Appliances

The two notification appliances were a Simplex 2901-9722 10" motor bell installed to accommodate owner preference and one EST Genesis G1-VM (white, no fire marking) remote strobe. The 2901-9722 was previously used in a school, and is still in use on the new garage. Formerly, there was a Gentex "Commander 3" GEC3-24WR (red, wall) horn/strobe.

Initiating Devices

Pull Stations

The pull stations consisted of one Chinese Pull Station, one Fire-Lite BG-12L and one GE-branded Edwards 270-SPO.

Automatic Detection Devices

There was one automatic detection device, a System Sensor C4W-B (i3) smoke detector that replaced a two wire equivalent. (C2W-BA)

New Garage Installation Photos

Installation Videos

Testing the Modified G1-AVRF "Genesis LED" horn-strobe (converted to remote strobe) File:LgenesisTest.mp4