''''St. Sebastian School'''' is an elementary school located in Chaparral, in Southeast Calgary. It is in the Calgary Catholic School District.  It has a capacity of about 500 students.  It was built in 2008, and some of the system is original.  
[[Category:Hobby]]
{| style="float:right;border:2px solid black"
|-
!System Specifications
|-
|
|-
|FACP: EST FireShield Plus<br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR
System Type: Conventional <br />Date of last upgrade: 2018 <br />Year Built: 2008
|}
'''St. Sebastian School''' is an elementary school located in Chaparral, in Southeast Calgary. It is in the Calgary Catholic School District.  It has a capacity of about 500 students.  It was built in 2008, and some of the system is original.  


Note: The pull stations are guesses, as the devices have only been seen from the outside, and no pull stations were visible from the front door.
Note: The pull stations are guesses, as the devices have only been seen from the outside, and no pull stations were visible from the front door.
==System Specifications==
==System Specifications==
====FACP====
====FACP====
The school is protected by an EST Fireshield Plus FSP-1004G conventional fire alarm control panel.
The school is protected by an EST FireShield Plus FSP-1004G conventional fire alarm control panel.
====Notification Appliances====
====Notification Appliances====
All notification appliances are EST Genesis G1R-HDVM (red, wall mount, no FIRE) horn/strobes. They are not original, because they replaced Edwards MB6-24 motor bells on EST "Integrity" 403-5A-R strobe plates.
All notification appliances are EST Genesis G1R-HDVM (red, wall mount, no FIRE) horn/strobes. They are not original, because they replaced Edwards MB6-24 motor bells on EST "Integrity" 403-5A-R strobe plates.

Revision as of 11:30, 18 May 2021

System Specifications
FACP: EST FireShield Plus
System Line Voltage: 120VAC
NAC Voltage: 24VFWR

System Type: Conventional
Date of last upgrade: 2018
Year Built: 2008

St. Sebastian School is an elementary school located in Chaparral, in Southeast Calgary. It is in the Calgary Catholic School District. It has a capacity of about 500 students. It was built in 2008, and some of the system is original.

Note: The pull stations are guesses, as the devices have only been seen from the outside, and no pull stations were visible from the front door.

System Specifications

FACP

The school is protected by an EST FireShield Plus FSP-1004G conventional fire alarm control panel.

Notification Appliances

All notification appliances are EST Genesis G1R-HDVM (red, wall mount, no FIRE) horn/strobes. They are not original, because they replaced Edwards MB6-24 motor bells on EST "Integrity" 403-5A-R strobe plates.

Initiating Devices

Pull Stations

The pull stations are likely Edwards 270-SPO. It is unknown if they are original.

Automatic Detection Devices

None noticed.