''''13226 Macleod Trail SE'''' is a multi-use building in Lake Bonavista, in SE Calgary.  It contains Canyon Meadows Cinemas, Reflex Supplements, Gymvt Avenida, Fortress Engineering, Fun 'N' More, Goodlife Fitness, and Pedalhead/Skiworks.  It was built in 1992, and some of the system is original.
{| style="float:right;border:2px solid black"
|-
! System Specifications
|-
|
|-
| FACP: Notifier AFP-400 <br />System Type:Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage:24VFWR <br />Date of last known Upgrade: Early 2010s <br />Year Opened: 1992, 1999
|}
 
'''13226 Macleod Trail SE''' is a multi-use building in Lake Bonavista, in SE Calgary.  It contains Canyon Meadows Cinemas, Reflex Supplements, Gymvt Avenida, Fortress Engineering, Fun 'N' More, Goodlife Fitness, and Pedalhead/Skiworks.  It was built in 1992, and only some notification appliances the system is original.


==System Specifications==
==System Specifications==
Line 6: Line 15:


====Notification Appliances====
====Notification Appliances====
There is a wide variety of notification appliances.  The movie theatre has mostly System Sensor "Spectralert" P241575 horn/strobes (red, wall mount, 15/75 candela).  These were installed in 1999.  Some replacements include a Mircom FHS-240R in the theatre's main corridor, a System Sensor "Spectralert Advance" P4R in the main corridor, and one in theatre 6.  The rest of the facility has Wheelock MBS-G10-24 bell/strobes, which are likely original from 1992.
There is a wide variety of notification appliances.  The movie theatre has mostly System Sensor "SpectrAlert" P241575 horn/strobes (red, wall mount, 15/75 candela).  These were installed in 1999.  Some replacements include a Mircom FHS-240R horn/strobe in the theatre's main corridor, a System Sensor "SpectrAlert Advance" P4R (red, wall mount, 4-wire) horn/strobe in the main corridor, and one in theatre 6.  The rest of the facility has Wheelock MBS-G10-24 motor bell/strobes, which are likely original from 1992.


===Initiating Devices===
===Initiating Devices===
Line 13: Line 22:


====Automatic Detection Devices====
====Automatic Detection Devices====
There are System Sensor 2451 smoke detectors located throughout the facility, from the 1999 renovation.
There are System Sensor 2451 photoelectric smoke detectors located throughout the facility, from the 1999 renovation.

Revision as of 20:03, 20 May 2021

System Specifications
FACP: Notifier AFP-400
System Type:Addressable
System Line Voltage: 120VAC
NAC Voltage:24VFWR
Date of last known Upgrade: Early 2010s
Year Opened: 1992, 1999

13226 Macleod Trail SE is a multi-use building in Lake Bonavista, in SE Calgary. It contains Canyon Meadows Cinemas, Reflex Supplements, Gymvt Avenida, Fortress Engineering, Fun 'N' More, Goodlife Fitness, and Pedalhead/Skiworks. It was built in 1992, and only some notification appliances the system is original.

System Specifications

FACP

The facility is protected by a Notifier AFP-400 addressable fire alarm control panel. It is located in the exit of the movie theatre. It was installed in 1999.

Notification Appliances

There is a wide variety of notification appliances. The movie theatre has mostly System Sensor "SpectrAlert" P241575 horn/strobes (red, wall mount, 15/75 candela). These were installed in 1999. Some replacements include a Mircom FHS-240R horn/strobe in the theatre's main corridor, a System Sensor "SpectrAlert Advance" P4R (red, wall mount, 4-wire) horn/strobe in the main corridor, and one in theatre 6. The rest of the facility has Wheelock MBS-G10-24 motor bell/strobes, which are likely original from 1992.

Initiating Devices

Pull Stations

Most pull stations are Notifier NFM-950B, from the 1999 renovation. Some areas have Notifier MPS-950B pull stations, and there are a few Mircom MS-401 pull stations as replacements.

Automatic Detection Devices

There are System Sensor 2451 photoelectric smoke detectors located throughout the facility, from the 1999 renovation.