More actions
(first automatic detection device!) |
|||
Line 25: | Line 25: | ||
|From the "Adaptabel" line. | |From the "Adaptabel" line. | ||
Came out of the Calgary General Hospital. | Came out of the Calgary General Hospital. | ||
Has been modified to allow easier wiring to panels. | |||
|- | |- | ||
|Unbranded Alarm Bell | |Unbranded Alarm Bell | ||
from Amazon | from Amazon | ||
| | | | ||
Line 36: | Line 38: | ||
|2017 | |2017 | ||
|Also known as the "FakeBell" | |Also known as the "FakeBell" | ||
Works on 9VDC | Works on 9VDC | ||
|- | |- | ||
Line 134: | Line 135: | ||
|1 | |1 | ||
|Addressable single-stage T-bar pull station with LED | |Addressable single-stage T-bar pull station with LED | ||
| | |2018 | ||
| | | | ||
|- | |- | ||
Line 156: | Line 157: | ||
|Conventional pull station | |Conventional pull station | ||
|1986 | |1986 | ||
| | |||
|} | |||
===Automatic Detection Devices=== | |||
{| class="wikitable" | |||
|+ | |||
!Model Number | |||
!Images | |||
!Quantity | |||
!Type | |||
!Manufacturing Date | |||
!Notes | |||
|- | |||
|Edwards 281C | |||
| | |||
|1 | |||
|Fixed Temperature/Rate-of-Rise Heat Detector | |||
|1994 | |||
| | | | ||
|} | |} |
Revision as of 00:45, 11 July 2021
I have been collecting fire alarms since 2017, and I have a good number of devices.
FACP (Panels)
None at the moment.
Notification Appliances
Model Number | Images | Quantity | Type | Voltage | Strobe Intensity | Loudness | Manufacturing Date | Notes |
---|---|---|---|---|---|---|---|---|
Edwards 333D | 1 | 6" Single-Stroke bell | 24VDC | N/A | 92 dB | 1976 | From the "Adaptabel" line.
Came out of the Calgary General Hospital. Has been modified to allow easier wiring to panels. | |
Unbranded Alarm Bell
from Amazon |
1 | 6" motor bell | 24VDC | N/A | 95 dB | 2017 | Also known as the "FakeBell"
Works on 9VDC | |
EST 757-5A-T | 1 | Temporal horn/strobe | 20-24VDC | 15cd | 98/102 dB | 1997 | From the "Integrity" lineup
Came out of a Walmart in Ontario. | |
Wheelock WM3T-24 | 1 | Weatherproof strobe | 18-31VDC | 117cd (78cd at -35C) | N/A | 1993 | ||
Mirtone 74306 | 1 | 10" motor bell | 24VDC | N/A | 95 dB? | Late 1980s-early 1990s |
Pull Stations
Model Number | Images | Quantity | Type | Manufacturing Date | Notes |
---|---|---|---|---|---|
Mircom MS-401 | 2 | Conventional, single stage pull station | Late 2010s (one 2017) | First alarm I ever got. | |
Edwards 270-GAO | 2 | Two-stage conventional pull station | 1977 | Came out of the Calgary General Hospital | |
Simplex 4251-30 | 1 | Dual-action (break glass) conventional T-bar pull station | 11th week of 1979 | ||
Edwards 275-C111 | 1 | Metal conventional pull station | late 1980s-early 1990s | ||
Mircom MS-401AD | 1 | Addressable single-stage pull station | 2008 | ||
Edwards 270-SPO | 2 | Conventional single-stage pull station | 1960s (1)
2009 (1) |
||
Edwards 270-SPOW | 1 | Conventional single-stage pull station with Wire Terminals | 2011 | ||
Simplex 4099-9004 | 1 | Addressable single-stage T-bar pull station with LED | 2018 | ||
Pyrotronics MS-51 | 1 | Conventional, bilingual single action pull station | 1980s | Branded "Pyr-A-Larm" | |
Fire-Lite BG-12 | 1 | Conventional dual-action pull station | 2001 | ||
Mirtone 73303 | 2 | Conventional pull station | 1986 |
Automatic Detection Devices
Model Number | Images | Quantity | Type | Manufacturing Date | Notes |
---|---|---|---|---|---|
Edwards 281C | 1 | Fixed Temperature/Rate-of-Rise Heat Detector | 1994 |