More actions
mNo edit summary |
|||
Line 7: | Line 7: | ||
| FACP: Mircom FX-2000 <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />Date of last known Upgrade: 2010s <br />Year Opened: 2006 | | FACP: Mircom FX-2000 <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />Date of last known Upgrade: 2010s <br />Year Opened: 2006 | ||
|} | |} | ||
'''Chaparral Pointe Condos''' is a 3-story apartment building in the neighborhood of Chaparral, SE Calgary. This apartment complex was built in 2006, and has the original fire alarm system. The system is serviced by Armstrong Monitoring, and formerly Sprouse Fire & Safety. | '''Chaparral Pointe Condos''' is a 3-story apartment building in the neighborhood of Chaparral, SE Calgary. This apartment complex was built in 2006, and has the original fire alarm system. The system is serviced by Armstrong Monitoring, and formerly Sprouse Fire & Safety. | ||
== System Specifications == | == System Specifications == | ||
==== FACP ==== | ==== FACP ==== | ||
The fire alarm control panel is a Mircom FX-2000, original to the complex from 2006. The panel is located in the front entrance. When in alarm condition, the panel makes all horns (FHS-240R and MH-S25WA) do code-3, with all strobes synchronized. | The fire alarm control panel is a Mircom FX-2000, original to the complex from 2006. The panel is located in the front entrance. When in alarm condition, the panel makes all horns (FHS-240R and MH-S25WA) do code-3, with all strobes synchronized. | ||
==== Notification Appliances ==== | ==== Notification Appliances ==== | ||
The main notification appliances are Mircom FHS-240R horn/strobes in the hallways and lobby, original from 2006. The units have Mircom MH-S25WA silenceable mini horns, one per bedroom. The horns are loud enough to be heard throughout the units. The FHS-240R horn/strobes are set on high volume, electromechanical horn. In one of the units, a Mircom mini-horn in a bedroom broke down, and was replaced with a System Sensor "SpectrAlert Advance" MHWZA (white, silenceable) mini-horn. | |||
The main notification appliances are Mircom FHS-240R horn/strobes in the hallways and lobby, original from 2006. The units have Mircom MH-S25WA silenceable mini horns, one per bedroom. | |||
=== Initiating Devices === | === Initiating Devices === | ||
==== Pull Stations ==== | ==== Pull Stations ==== | ||
All of the pull stations are original from 2006. They are Mircom MS-401AD addressable pull stations. | |||
All of the pull stations are original from 2006. They are Mircom MS- | |||
==== Automatic Detection Devices ==== | ==== Automatic Detection Devices ==== | ||
The hallways, stairwells, common areas and elevator lobbies have Mircom MIX-2251AP addressable, photoelectric smoke detectors. | The hallways, stairwells, common areas and elevator lobbies have Mircom MIX-2251AP addressable, photoelectric smoke detectors. |
Revision as of 13:10, 5 August 2021
System Specifications |
---|
FACP: Mircom FX-2000 System Type: Addressable System Line Voltage: 120VAC NAC Voltage: 24VFWR Date of last known Upgrade: 2010s Year Opened: 2006 |
Chaparral Pointe Condos is a 3-story apartment building in the neighborhood of Chaparral, SE Calgary. This apartment complex was built in 2006, and has the original fire alarm system. The system is serviced by Armstrong Monitoring, and formerly Sprouse Fire & Safety.
System Specifications
FACP
The fire alarm control panel is a Mircom FX-2000, original to the complex from 2006. The panel is located in the front entrance. When in alarm condition, the panel makes all horns (FHS-240R and MH-S25WA) do code-3, with all strobes synchronized.
Notification Appliances
The main notification appliances are Mircom FHS-240R horn/strobes in the hallways and lobby, original from 2006. The units have Mircom MH-S25WA silenceable mini horns, one per bedroom. The horns are loud enough to be heard throughout the units. The FHS-240R horn/strobes are set on high volume, electromechanical horn. In one of the units, a Mircom mini-horn in a bedroom broke down, and was replaced with a System Sensor "SpectrAlert Advance" MHWZA (white, silenceable) mini-horn.
Initiating Devices
Pull Stations
All of the pull stations are original from 2006. They are Mircom MS-401AD addressable pull stations.
Automatic Detection Devices
The hallways, stairwells, common areas and elevator lobbies have Mircom MIX-2251AP addressable, photoelectric smoke detectors.