Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Alberta Fire Alarms' collection: Difference between revisions

From FireAlarmPedia
(first automatic detection device!)
mNo edit summary
Line 1: Line 1:
I have been collecting fire alarms since 2017, and I have a good number of devices.
I have been collecting fire alarms since 2017, and I have a good number of devices.
=== FACP (Panels) ===
=== FACP (Panels) ===
None at the moment.
{| class="wikitable"
=== Notification Appliances ===
|+
!Model
!Image
!Type
!Zone/Point Capacity
!NACs
!Coding Options
!Power Supply
!NAC Voltage
!System Line Voltage
!Synchronization Support
!Manufacturing Date
!Origin
|-
|Fire-Lite MS-4
|
|Conventional
|4 zones
|2
|Code-3, continuous
|3A (expandable to 6A)
|24VFWR
|120VAC
|System Sensor, Wheelock, Gentex
|December 18, 2015
|[[User:Yycsfirealarmnimrod|Yycsfirealarmnimrod]]
|}
===Notification Appliances===
{| class="wikitable"
{| class="wikitable"
|+
|+
!Model Number
!Model Number
!Images  
!Images
!Quantity
! Quantity
!Type
!Type
!Voltage
!Voltage
Line 34: Line 61:
|6" motor bell
|6" motor bell
|24VDC
|24VDC
|N/A
| N/A
|95 dB
|95 dB
|2017
|2017
Line 45: Line 72:
|Temporal horn/strobe
|Temporal horn/strobe
|20-24VDC
|20-24VDC
|15cd
| 15cd
|98/102 dB
|98/102 dB
|1997
|1997
Line 63: Line 90:
|Mirtone 74306
|Mirtone 74306
|
|
|1
| 1
|10" motor bell
|10" motor bell
|24VDC
|24VDC
Line 69: Line 96:
|95 dB?
|95 dB?
|Late 1980s-early 1990s
|Late 1980s-early 1990s
|
|-
|Edwards/EST (GE) 682-1C
|
|1
|Mini-horn
|20-24VDC
|N/A
|91 dB?
|2008
|
|
|}
|}
=== Pull Stations ===
=== Pull Stations===
{| class="wikitable"
{| class="wikitable"
|+
|+
Line 81: Line 118:
!Notes
!Notes
|-
|-
|Mircom MS-401
| Mircom MS-401
|
|
|2
|2
|Conventional, single stage pull station
| Conventional, single stage pull station
|Late 2010s (one 2017)
|Late 2010s (one 2017)
|First alarm I ever got.
|First alarm I ever got.
Line 99: Line 136:
|1
|1
|Dual-action (break glass) conventional T-bar pull station
|Dual-action (break glass) conventional T-bar pull station
|11th week of 1979
| 11th week of 1979
|
|
|-
|-
Line 111: Line 148:
|Mircom MS-401AD
|Mircom MS-401AD
|
|
|1
| 1
|Addressable single-stage pull station
|Addressable single-stage pull station
|2008
|2008
|
|
|-
|-
|Edwards 270-SPO
| Edwards 270-SPO
|
|
|2
|2
Line 141: Line 178:
|
|
|1
|1
|Conventional, bilingual single action pull station
| Conventional, bilingual single action pull station
|1980s
|1980s
|Branded "Pyr-A-Larm"
|Branded "Pyr-A-Larm"
Line 155: Line 192:
|
|
|2
|2
|Conventional pull station
| Conventional pull station
|1986
|1986
|
|
Line 174: Line 211:
|Fixed Temperature/Rate-of-Rise Heat Detector
|Fixed Temperature/Rate-of-Rise Heat Detector
|1994
|1994
|
|-
|Edwards 280B-PL?
|
|1
|Fixed Temperature/Rate-of-Rise Heat Detector
|2010
|Came with base
|-
|Mirtone 73340
|
|1
|Fixed Temperature/Rate-of-Rise Heat Detector
|1998
|
|-
|Edwards C2M-PD
|
|1
|2-wire, self-diagnostic photoelectric smoke detector
|2010
|
|-
|System Sensor 2400A
|
|1
|direct-wire, photoelectric smoke detector
|Unknown (1990s-2000s)
|
|
|}
|}

Revision as of 19:04, 22 August 2021

I have been collecting fire alarms since 2017, and I have a good number of devices.

FACP (Panels)

Model Image Type Zone/Point Capacity NACs Coding Options Power Supply NAC Voltage System Line Voltage Synchronization Support Manufacturing Date Origin
Fire-Lite MS-4 Conventional 4 zones 2 Code-3, continuous 3A (expandable to 6A) 24VFWR 120VAC System Sensor, Wheelock, Gentex December 18, 2015 Yycsfirealarmnimrod

Notification Appliances

Model Number Images Quantity Type Voltage Strobe Intensity Loudness Manufacturing Date Notes
Edwards 333D 1 6" Single-Stroke bell 24VDC N/A 92 dB 1976 From the "Adaptabel" line.

Came out of the Calgary General Hospital.

Has been modified to allow easier wiring to panels.

Unbranded Alarm Bell

from Amazon

1 6" motor bell 24VDC N/A 95 dB 2017 Also known as the "FakeBell"

Works on 9VDC

EST 757-5A-T 1 Temporal horn/strobe 20-24VDC 15cd 98/102 dB 1997 From the "Integrity" lineup

Came out of a Walmart in Ontario.

Wheelock WM3T-24 1 Weatherproof strobe 18-31VDC 117cd (78cd at -35C) N/A 1993
Mirtone 74306 1 10" motor bell 24VDC N/A 95 dB? Late 1980s-early 1990s
Edwards/EST (GE) 682-1C 1 Mini-horn 20-24VDC N/A 91 dB? 2008

Pull Stations

Model Number Images Quantity Type Manufacturing Date Notes
Mircom MS-401 2 Conventional, single stage pull station Late 2010s (one 2017) First alarm I ever got.
Edwards 270-GAO 2 Two-stage conventional pull station 1977 Came out of the Calgary General Hospital
Simplex 4251-30 1 Dual-action (break glass) conventional T-bar pull station 11th week of 1979
Edwards 275-C111 1 Metal conventional pull station late 1980s-early 1990s
Mircom MS-401AD 1 Addressable single-stage pull station 2008
Edwards 270-SPO 2 Conventional single-stage pull station 1960s (1)

2009 (1)

Edwards 270-SPOW 1 Conventional single-stage pull station with Wire Terminals 2011
Simplex 4099-9004 1 Addressable single-stage T-bar pull station with LED 2018
Pyrotronics MS-51 1 Conventional, bilingual single action pull station 1980s Branded "Pyr-A-Larm"
Fire-Lite BG-12 1 Conventional dual-action pull station 2001
Mirtone 73303 2 Conventional pull station 1986

Automatic Detection Devices

Model Number Images Quantity Type Manufacturing Date Notes
Edwards 281C 1 Fixed Temperature/Rate-of-Rise Heat Detector 1994
Edwards 280B-PL? 1 Fixed Temperature/Rate-of-Rise Heat Detector 2010 Came with base
Mirtone 73340 1 Fixed Temperature/Rate-of-Rise Heat Detector 1998
Edwards C2M-PD 1 2-wire, self-diagnostic photoelectric smoke detector 2010
System Sensor 2400A 1 direct-wire, photoelectric smoke detector Unknown (1990s-2000s)