'''Fish Creek-Lacombe Station''' is an LRT station in Calgary, Alberta. It serves several communities in Southwest and Southeast Calgary. The station is mostly outdoors, but has a small building with ticket machines, plus a fire alarm system. The station was built in 2001, and has the original system. This is also the only station on the Red line’s South leg to have a Notifier system. | |||
==System Specifications== | ==System Specifications== | ||
Line 15: | Line 15: | ||
====Notification Appliances==== | ====Notification Appliances==== | ||
There are only two notification appliances in the building. Both are Notifier KMS-6-24VDC motor bells (6” gong”) on Wheelock RSSP-2415W-FR strobe plates. | There are only two notification appliances in the building. Both are Notifier KMS-6-24VDC motor bells (6” gong”) on Wheelock RSSP-2415W-FR (15cd) strobe plates. | ||
===Initiating Devices=== | ===Initiating Devices=== |
Revision as of 12:06, 15 November 2021
System Specifications |
---|
FACP: Notifier AFP-200C System Type: Addressable System Line Voltage: 120VAC NAC Voltage: 24VDC Date of last known Upgrade: N/A Year Opened: 2001 |
Fish Creek-Lacombe Station is an LRT station in Calgary, Alberta. It serves several communities in Southwest and Southeast Calgary. The station is mostly outdoors, but has a small building with ticket machines, plus a fire alarm system. The station was built in 2001, and has the original system. This is also the only station on the Red line’s South leg to have a Notifier system.
System Specifications
FACP
The station is protected by a Notifier AFP-200C addressable fire alarm system. The panel is located in an electrical room, and unconfirmed, but it is likely an AFP-200 based on the age and size of the building. The system runs on Notifier’s CLIP addressable protocol, and does code 3 in alarm.
Notification Appliances
There are only two notification appliances in the building. Both are Notifier KMS-6-24VDC motor bells (6” gong”) on Wheelock RSSP-2415W-FR (15cd) strobe plates.
Initiating Devices
Pull Stations
Both pull stations are Notifier NFM-950B conventional single-action pull stations. These likely have Notifier MMX-101A CLIP addressable modules connected to them, as they are conventional.
Automatic Detection Devices
None noticed.