Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Safeway (Dalhousie): Difference between revisions

From FireAlarmPedia
(Well, the 6632 is no more after 25 years of service. A moment of silence for the now-gone system. Typical Simplex 4007ES Safeway system. XD)
(Safeway gets its cock sucked by JCI.)
Line 7: Line 7:
| FACP: Simplex 4007ES <br />System Type: Hybrid <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />Date of last known Upgrade: 2021 <br />Year Opened: 1996
| FACP: Simplex 4007ES <br />System Type: Hybrid <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />Date of last known Upgrade: 2021 <br />Year Opened: 1996
|}
|}
'''Safeway''' is a chain of grocery stores in Alberta. This particular location is in Dalhousie, NW Calgary. It is officially called Safeway Dalhousie Station, due to being adjacent to the Dalhousie station on the CTrain line. It was built in 1996, and the fire alarm system was recently replaced, and only a few pull stations remain. The store is in a large plaza, however only the Safeway is protected by a fire alarm system.
'''Safeway''' is a chain of grocery stores in Alberta. This particular location is in Dalhousie, NW Calgary. It is officially called Safeway Dalhousie Station, due to being adjacent to the Dalhousie station on the CTrain line. It was built in 1996, and the fire alarm system was recently replaced, and only a few pull stations remain. The store is in a large plaza, however only the Safeway is protected by a fire alarm system.
== System Specifications ==
== System Specifications ==
==== FACP ====
==== FACP ====
 
The fire alarm panel is a Simplex 4007ES, specifically 4007-9202 (Platinum cabinet). It is located in the entrance on the right. It replaced the original EST 6632 in 2021 because Safeway likes Simplex, and because the 6632 was large, there is drywall covering the 6632's space. The permit issued for this upgrade was "Fire Alarm System Modification - Replace Fire Alarm Panel and select initiating/signaling devices." on February 12, 2021.  
The fire alarm panel is a Simplex 4007ES, specifically 4007-9202 (Platinum cabinet). It is located in the entrance on the right. It replaced the original EST 6632 in 2021 most likely due to a CPU failure, and because the 6632 was large, there is drywall covering the 6632's space. The permit issued for this upgrade was "Fire Alarm System Modification - Replace Fire Alarm Panel and select initiating/signaling devices." on February 12, 2021.  
 
==== Notification Appliances ====
==== Notification Appliances ====
The notification appliances are all from Simplex's "TrueAlert" lineup. The store has Simplex 4906-9127 (red, wall-mount, SmartSync) horn/strobes installed in the original bell/strobes places, leaving the area not covered by the horn/strobe unpainted. On the ceilings, there are Simplex 4906-9104 (white, ceiling-mount, SmartSync) remote strobes, installed in place of the previous strobes. Outside the entrance, there is a Simplex 4906-9131 (red, wall-mount, SmartSync) weatherproof remote strobe.
The notification appliances are all from Simplex's "TrueAlert" lineup. The store has Simplex 4906-9127 (red, wall-mount, SmartSync) horn/strobes installed in the original bell/strobes places, leaving the area not covered by the horn/strobe unpainted. On the ceilings, there are Simplex 4906-9104 (white, ceiling-mount, SmartSync) remote strobes, installed in place of the previous strobes. Outside the entrance, there is a Simplex 4906-9131 (red, wall-mount, SmartSync) weatherproof remote strobe.
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
The pull stations are still mostly the original Edwards 270-SPO pull stations, but there is one Simplex 2099-9754 at the entrance, installed during the upgrade.
The pull stations are still mostly the original Edwards 270-SPO pull stations, but there is one Simplex 2099-9754 at the entrance, installed during the upgrade.
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
None noticed.  
None noticed.  
== Former System Specifications ==
== Former System Specifications ==
{| style="float:right;border:2px solid black"
{| style="float:right;border:2px solid black"
Line 40: Line 28:
|}
|}
==== FACP ====
==== FACP ====
The fire alarm control panel was an EST 6632. It was original and was located in the entrance on the right. In 2021, it was replaced with a Simplex 4007ES.  
The fire alarm control panel was an EST 6632. It was original and was located in the entrance on the right. In 2021, it was replaced with a Simplex 4007ES.  
==== Notification Appliances ====
==== Notification Appliances ====
 
The notification appliances mainly consisted of the original Edwards 439D-10AWC vibrating bells on EST "Integrity" 403-5A-R strobe plates. In the floral section, there was an Edwards 439D-10AWC bell on a Wheelock RSSP-24MCW strobe plate, the Wheelock strobe plate replaced an EST strobe plate that stopped working. On the ceiling, there was a mix of EST "Integrity" 202-5A-T (red) and 202-5A-TW (white) remote strobes scattered around, all with the standard wall "FIRE" lenses. They were original, and they are for additional visual coverage. Some of them had been replaced with System Sensor "SpectrAlert Advance" SR (red, wall) remote strobes, again on the ceiling. For outdoor notification, the there was an Edwards 439D-10AWC vibrating bell on an EST 403-5A-R strobe plate at the entrance.
The notification appliances mainly consisted of the original Edwards 439D-10AWC vibrating bells on EST "Integrity" 403-5A-R strobe plates. In the floral section, there was an Edwards 439D-10AWC bell on a Wheelock RSSP-24MCW strobe plate, the Wheelock strobe plate replaced an EST strobe plate that stopped working. On the ceiling, there was a mix of EST "Integrity" 202-5A-T (red) and 202-5A-TW (white) remote strobes scattered around, all with the standard wall "FIRE" lenses. They were original, and they are for additional visual coverage. Some of them had been replaced with System Sensor "SpectrAlert Advance" SR (red, wall) remote strobes, again on the ceiling. For outdoor notification, the there was an Edwards 439D-10AWC vibrating bell on an EST 403-5A-R strobe plate at the entrance.
 
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
The pull stations were all the original Edwards 270-SPO. Some are still installed.
The pull stations were all the original Edwards 270-SPO. Some are still installed.
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
None noticed.
None noticed.

Revision as of 09:25, 19 November 2021

System Specifications
FACP: Simplex 4007ES
System Type: Hybrid
System Line Voltage: 120VAC
NAC Voltage: 24VDC
Date of last known Upgrade: 2021
Year Opened: 1996

Safeway is a chain of grocery stores in Alberta. This particular location is in Dalhousie, NW Calgary. It is officially called Safeway Dalhousie Station, due to being adjacent to the Dalhousie station on the CTrain line. It was built in 1996, and the fire alarm system was recently replaced, and only a few pull stations remain. The store is in a large plaza, however only the Safeway is protected by a fire alarm system.

System Specifications

FACP

The fire alarm panel is a Simplex 4007ES, specifically 4007-9202 (Platinum cabinet). It is located in the entrance on the right. It replaced the original EST 6632 in 2021 because Safeway likes Simplex, and because the 6632 was large, there is drywall covering the 6632's space. The permit issued for this upgrade was "Fire Alarm System Modification - Replace Fire Alarm Panel and select initiating/signaling devices." on February 12, 2021.

Notification Appliances

The notification appliances are all from Simplex's "TrueAlert" lineup. The store has Simplex 4906-9127 (red, wall-mount, SmartSync) horn/strobes installed in the original bell/strobes places, leaving the area not covered by the horn/strobe unpainted. On the ceilings, there are Simplex 4906-9104 (white, ceiling-mount, SmartSync) remote strobes, installed in place of the previous strobes. Outside the entrance, there is a Simplex 4906-9131 (red, wall-mount, SmartSync) weatherproof remote strobe.

Initiating Devices

Pull Stations

The pull stations are still mostly the original Edwards 270-SPO pull stations, but there is one Simplex 2099-9754 at the entrance, installed during the upgrade.

Automatic Detection Devices

None noticed.

Former System Specifications

System Specifications
FACP: EST 6632
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
Date of last known Upgrade: Early 2010s
Year Decommissioned: 2021

FACP

The fire alarm control panel was an EST 6632. It was original and was located in the entrance on the right. In 2021, it was replaced with a Simplex 4007ES.

Notification Appliances

The notification appliances mainly consisted of the original Edwards 439D-10AWC vibrating bells on EST "Integrity" 403-5A-R strobe plates. In the floral section, there was an Edwards 439D-10AWC bell on a Wheelock RSSP-24MCW strobe plate, the Wheelock strobe plate replaced an EST strobe plate that stopped working. On the ceiling, there was a mix of EST "Integrity" 202-5A-T (red) and 202-5A-TW (white) remote strobes scattered around, all with the standard wall "FIRE" lenses. They were original, and they are for additional visual coverage. Some of them had been replaced with System Sensor "SpectrAlert Advance" SR (red, wall) remote strobes, again on the ceiling. For outdoor notification, the there was an Edwards 439D-10AWC vibrating bell on an EST 403-5A-R strobe plate at the entrance.

Initiating Devices

Pull Stations

The pull stations were all the original Edwards 270-SPO. Some are still installed.

Automatic Detection Devices

None noticed.