| FACP: Fire-Lite CMP-2402 <br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />Date of last known Upgrade: 2017 <br />Year Opened: 1982 | | FACP: Fire-Lite CMP-2402 <br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />Date of last known Upgrade: 2017 <br />Year Opened: 1982 | ||
|} | |} | ||
'''Calaway Park''' is a large amusement park located just west of Calgary, in Springbank, Alberta. This page will cover the Calaway Cafe, which is the main cafeteria in the park, and possibly the only building in the park with a fire alarm system. The building was built in 1982, when the park opened. The system was replaced in 2017, however. | |||
'''Calaway Park''' is a large amusement park located just west of Calgary, in Springbank, Alberta. | |||
==System Specifications (current system)== | ==System Specifications (current system)== | ||
====FACP==== | ====FACP==== | ||
The building is protected by a Fire-Lite CMP-2402 conventional fire alarm system. | The building is protected by a Fire-Lite CMP-2402 conventional fire alarm system. This is unconfirmed, but the CMP is the only conventional panel Fire-Lite offers in Canada. This panel has no coding options, so the system does continuous in alarm. | ||
====Notification Appliances==== | ====Notification Appliances==== | ||
The notification appliances are Edwards 439D-10AWC vibrating bells (10” gong). | The notification appliances are Edwards 439D-10AWC vibrating bells (10” gong). These were not replaced when the system was upgraded, and are original. | ||
===Initiating Devices=== | ===Initiating Devices=== | ||
====Pull Stations==== | ====Pull Stations==== | ||
All pull stations are Fire-Lite FI-MPS-SC conventional single-action “T-bar” pull stations. | All pull stations are Fire-Lite FI-MPS-SC conventional single-action “T-bar” pull stations. | ||
====Automatic Detection Devices==== | ====Automatic Detection Devices==== | ||
There are possibly System Sensor i3 C2W-BA conventional smoke detectors in the building. | There are possibly System Sensor i3 C2W-BA conventional smoke detectors in the building. | ||
==System Specifications (original system)== | ==System Specifications (original system)== | ||
====FACP==== | ====FACP==== | ||
The building was protected by an Edwards 1527 conventional fire alarm system. | The building was protected by an Edwards 1527 conventional fire alarm system. This panel was installed in 1982, and decommissioned in 2017. The system did continuous in alarm, as the panel had no coding options. | ||
====Notification Appliances==== | ====Notification Appliances==== | ||
The Edwards 439D-10AWC bells are original, and were on the 1527. | The Edwards 439D-10AWC bells are original, and were on the 1527. | ||
===Initiating Devices=== | ===Initiating Devices=== | ||
====Pull Stations==== | ====Pull Stations==== | ||
All pull stations were Edwards 274-111 conventional single-action pull stations. | All pull stations were Edwards 274-111 conventional single-action pull stations. These were replaced when the system was upgraded, although it was conventional. | ||
====Automatic Detection Devices==== | ====Automatic Detection Devices==== | ||
This system pre-dated CFAA codes requiring smoke detectors, so there were none. | This system pre-dated CFAA codes requiring smoke detectors, so there were none. |
Revision as of 09:42, 13 December 2021
System Specifications |
---|
FACP: Fire-Lite CMP-2402 System Type: Conventional System Line Voltage: 120VAC NAC Voltage: 24VFWR Date of last known Upgrade: 2017 Year Opened: 1982 |
Calaway Park is a large amusement park located just west of Calgary, in Springbank, Alberta. This page will cover the Calaway Cafe, which is the main cafeteria in the park, and possibly the only building in the park with a fire alarm system. The building was built in 1982, when the park opened. The system was replaced in 2017, however.
System Specifications (current system)
FACP
The building is protected by a Fire-Lite CMP-2402 conventional fire alarm system. This is unconfirmed, but the CMP is the only conventional panel Fire-Lite offers in Canada. This panel has no coding options, so the system does continuous in alarm.
Notification Appliances
The notification appliances are Edwards 439D-10AWC vibrating bells (10” gong). These were not replaced when the system was upgraded, and are original.
Initiating Devices
Pull Stations
All pull stations are Fire-Lite FI-MPS-SC conventional single-action “T-bar” pull stations.
Automatic Detection Devices
There are possibly System Sensor i3 C2W-BA conventional smoke detectors in the building.
System Specifications (original system)
FACP
The building was protected by an Edwards 1527 conventional fire alarm system. This panel was installed in 1982, and decommissioned in 2017. The system did continuous in alarm, as the panel had no coding options.
Notification Appliances
The Edwards 439D-10AWC bells are original, and were on the 1527.
Initiating Devices
Pull Stations
All pull stations were Edwards 274-111 conventional single-action pull stations. These were replaced when the system was upgraded, although it was conventional.
Automatic Detection Devices
This system pre-dated CFAA codes requiring smoke detectors, so there were none.