More actions
(Created Page: Marsden Hotel (The Fort Room)) |
mNo edit summary |
||
Line 1: | Line 1: | ||
{| style="float:right;border:2px solid black" | |||
|- | |||
! System Specifications | |||
|- | |||
| | |||
|- | |||
| FACP: Honeywell Sensiscan 1000 <br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />Date of last known Upgrade: 1990s? <br />Year Opened: 1960s | |||
|} | |||
The year of construction is unknown but the system appears to be from the mid 1960s. | '''The Marsden Hotel (The Fort Room)''' is a hotel and bar located in Marsden, SK. The year of construction is unknown but the system appears to be from the mid 1960s. This building may be torn down in the near future as it is currently unowned and has been for 3 years | ||
This building may be torn down in the near future as it is currently unowned and has been for 3 years | |||
Note: These specifications are as of 2017 and from the memory of user:ThePurpleMage | Note: These specifications are as of 2017 and from the memory of user:ThePurpleMage | ||
==System Specifications== | ==System Specifications== | ||
====FACP==== | ====FACP==== | ||
The building is protected by a Honeywell Senciscan 1000 conventional fire alarm control panel. The panel is located behind the front desk. When in alarm the system most likely does Steady code/Continuous | The building is protected by a Honeywell Senciscan 1000 conventional fire alarm control panel. The panel is located behind the front desk. When in alarm the system most likely does Steady code/Continuous. | ||
====Notification Appliances==== | ====Notification Appliances==== | ||
The Notification Appliances consist of Unknown Bells (possibly Honeywell, Grey in colour, 5 or 6 inch, has a label that says “Fire Bell 24V”). | The Notification Appliances consist of Unknown Bells (possibly Honeywell, Grey in colour, 5 or 6 inch, has a label that says “Fire Bell 24V”). | ||
===Initiating Devices=== | ===Initiating Devices=== | ||
====Pull Stations==== | ====Pull Stations==== | ||
The manual pull stations consist of a mix of what appear to be Fire Lite | The manual pull stations consist of a mix of what appear to be Fire Lite BG-5 and Fire Lite BG-6 conventional single action pull stations. | ||
====Automatic Detection Devices==== | ====Automatic Detection Devices==== | ||
None noticed. | None noticed. |
Revision as of 14:34, 22 February 2022
System Specifications |
---|
FACP: Honeywell Sensiscan 1000 System Type: Conventional System Line Voltage: 120VAC NAC Voltage: 24VDC Date of last known Upgrade: 1990s? Year Opened: 1960s |
The Marsden Hotel (The Fort Room) is a hotel and bar located in Marsden, SK. The year of construction is unknown but the system appears to be from the mid 1960s. This building may be torn down in the near future as it is currently unowned and has been for 3 years
Note: These specifications are as of 2017 and from the memory of user:ThePurpleMage
System Specifications
FACP
The building is protected by a Honeywell Senciscan 1000 conventional fire alarm control panel. The panel is located behind the front desk. When in alarm the system most likely does Steady code/Continuous.
Notification Appliances
The Notification Appliances consist of Unknown Bells (possibly Honeywell, Grey in colour, 5 or 6 inch, has a label that says “Fire Bell 24V”).
Initiating Devices
Pull Stations
The manual pull stations consist of a mix of what appear to be Fire Lite BG-5 and Fire Lite BG-6 conventional single action pull stations.
Automatic Detection Devices
None noticed.