Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

ThePurpleMage's Collection: Difference between revisions

From FireAlarmPedia
No edit summary
(Fixed some spelling mistakes as well as adding some new stuff)
Line 22: Line 22:
|6 Zones
|6 Zones
|2 NACs
|2 NACs
|None
|Continuous
|
|
|24VDC
|24VDC
Line 38: Line 38:
|4 Zones
|4 Zones
|2 NACs
|2 NACs
|None
|Continuous
|
|
|24VFWR
|24VFWR
Line 44: Line 44:
|None
|None
|1984
|1984
|Lost, I can't find it
|In a box of stuff that I misplaced  years ago
|Shane
|Shane
(Sprouse)  
(Sprouse)  
Line 54: Line 54:
|1 Zone
|1 Zone
|1 NAC
|1 NAC
|None
|Continuous
|
|
|24VFWR
|24VFWR
Line 69: Line 69:
|1 Zone
|1 Zone
|1 NAC
|1 NAC
|None
|Continuous
|
|
|24VFWR
|24VFWR
Line 103: Line 103:
|1000
|1000
|8 NACs
|8 NACs
|Continuous, Temporal, Custom
|Continuous, Temporal, Coder (Custom)
|
|16.5 A
|24VFWR
|24VFWR
|120VAC
|120VAC
|Genesis
|Genesis
|2017
|2019
|My favourite panel.
|My favourite panel.


Line 115: Line 115:
|Carl
|Carl
(Legacy)
(Legacy)
|-
|IBM
4201-2
(Soon to be obtained)
|
|Coded
|N/A
|2
|4-4
|
|120VAC
|120VAC
|Npne
|1940s
|Will be my oldest panel by far
|Glenn James
(Old School Fire Alarms)
|}
|}
=== Notification Appliances ===
=== Notification Appliances ===
Line 228: Line 246:


Conventional
Conventional
|Unkown
|Unknown
|
|
|AdenK2333
|AdenK2333
|-
|-
|Couch
|Couch
F1GG "Chevron
F1GG "Chevron"
|
|
|1
|1
Line 240: Line 258:


Conventional
Conventional
|Unkown
|Unknown
|Broke from being slammed
|Broke from being slammed
|Shane (Sprouse)
|Shane (Sprouse)
|-
|-
|Notifier
|Notifier
NBG12L
NBG12LX
|
|
|1
|1
Line 252: Line 270:


Conventional
Conventional
|Unkown
|Unknown
|Was formerly and NBG12LX
|
|Unknown
|Unknown
|-
|-
Line 264: Line 282:


Conventional
Conventional
|Unkown
|Unknown
|
|
|YYCFireAlarmNimrod
|YYCFireAlarmNimrod
Line 276: Line 294:


Conventional
Conventional
|Unkown
|Unknown
|
|
|YYCFireAlarmNimrod
|YYCFireAlarmNimrod
Line 332: Line 350:
|Rate of Rise Heat
|Rate of Rise Heat
Addressable
Addressable
|Unkown
|Unknown
|
|
|Unknown
|Unknown
|-
|Notifier
FSP-851
|
|1
|Photo Smoke
Addressable
|2018?
|Came new old stock
|Phuntington
|-
|Notifier
FSP-951
|
|1
|Photo Smoke
Addressable
|2022
|Came brand new
|Phuntington
|}
|}

Revision as of 11:24, 5 April 2022

Panels (FACP)

Model Image Type Zone/Point Capacity NACs Coding Options Power Supply NAC Voltage System Line Voltage Synchronization Support Manufacturing Date Notes Origin
Edwards

2280

Conventional 6 Zones 2 NACs Continuous 24VDC 120VAC None 1979 My oldest panel Carl

(Legacy)

Fire Lite

Miniscan 112

Conventional 4 Zones 2 NACs Continuous 24VFWR 120VAC None 1984 In a box of stuff that I misplaced years ago Shane

(Sprouse)

Notifier/Emhart

Unknown Model

Conventional 1 Zone 1 NAC Continuous 24VFWR 120VAC None Unknown None of the LEDs work Shane (Sprouse)
Mirtone

70605

Conventional 1 Zone 1 NAC Continuous 24VFWR 120VAC None Unknown My Rarest panel. I'm the only collector to own one Carl (Legacy)
Notifier

AFP-200C

Addressable 99 Points (Modules)

99 Points

(Detectors)

4 NACs Continuous, Temporal, 120BPM, California 24VDC 120VAC System Sensor, Wheelock, Gentex 2002 Carl

(Legacy)

EST

IO-1000

Addressable 1000 8 NACs Continuous, Temporal, Coder (Custom) 16.5 A 24VFWR 120VAC Genesis 2019 My favourite panel.


In a retrofit cabinet

Carl

(Legacy)

IBM

4201-2

(Soon to be obtained)

Coded N/A 2 4-4 120VAC 120VAC Npne 1940s Will be my oldest panel by far Glenn James

(Old School Fire Alarms)

Notification Appliances

Model Number Images Quantity Type Product Line Voltage Strobe Intensity Sound Output Manufacturing Date Notes Origin
Edwards

439D-6AWC

1 Vibrating Bell 24VDC 98db Unknown
Simplex

2901 2723

3 Motor Bell 24VDC Unkown 2012
Some old horn 1 Mechanical horn 12VAC 133db Unknown LOUD!!!!

looks looks like it could have a projector

EST

G1-HDVM

1 Horn/Strobe Genesis 24VDC Multi CD 103db Unkown AdenK2333
EST

G1-VM

2 Remote Strobe Genesis 24VDC Multi CD 2017 Carl (Lagacy)
Wheelock MT-241575W 1 Horn/Storbe 24VDC 15/75 CD Varying Unknown AdenK2333

Pull Stations

Model Number Image Quantity Type Manufacturing

Date

Notes Origin
Simplex

4251-20

1 Single Action

Single Stage

Conventional

Unknown AdenK2333
Couch

F1GG "Chevron"

1 Single Action

Single Stage

Conventional

Unknown Broke from being slammed Shane (Sprouse)
Notifier

NBG12LX

1 Dual Action

Single Stage

Conventional

Unknown Unknown
Notifier

LNG-1R

1 Dual Action

Single Stage

Conventional

Unknown YYCFireAlarmNimrod
Notifier

MPS-950B

1 Single Action

Single Stage

Conventional

Unknown YYCFireAlarmNimrod
Edwards

270-SPOW

1 Single Action

Single Stage

Conventional

Switch is no longer functional. Screw is so stripped its unusable Unknown

Automatic Detectors

Model Number Image Quantity Type Manufacturing

Date

Notes Origin
Edwards

C2M-PD

1 Photo Smoke

Conventional

2-Wire

Unknown YYCFireAlarmNimrod
EST

SIGA-PD

1 Photo Smoke

Addressable

2017 Came brand new EST Tech
Vigilant

V-HRD

1 Rate of Rise Heat

Addressable

Unknown Unknown
Notifier

FSP-851

1 Photo Smoke

Addressable

2018? Came new old stock Phuntington
Notifier

FSP-951

1 Photo Smoke

Addressable

2022 Came brand new Phuntington