Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

ThePurpleMage's Collection: Difference between revisions

From FireAlarmPedia
(Fixed some spelling mistakes as well as adding some new stuff)
Line 44: Line 44:
|None
|None
|1984
|1984
|In a box of stuff that I misplaced years ago
|In a box of stuff that I misplaced years ago
|Shane
|Shane
(Sprouse)  
(Sprouse)  
Line 128: Line 128:
|120VAC
|120VAC
|120VAC
|120VAC
|Npne
|None
|1940s
|1940s
|Will be my oldest panel by far
|Will be my oldest panel by far
Line 368: Line 368:
|
|
|1
|1
|Photo Smoke  
|Photo Smoke
Addressable
Addressable
|2022
|2022

Revision as of 11:43, 5 April 2022

Panels (FACP)

Model Image Type Zone/Point Capacity NACs Coding Options Power Supply NAC Voltage System Line Voltage Synchronization Support Manufacturing Date Notes Origin
Edwards

2280

Conventional 6 Zones 2 NACs Continuous 24VDC 120VAC None 1979 My oldest panel Carl

(Legacy)

Fire Lite

Miniscan 112

Conventional 4 Zones 2 NACs Continuous 24VFWR 120VAC None 1984 In a box of stuff that I misplaced years ago Shane

(Sprouse)

Notifier/Emhart

Unknown Model

Conventional 1 Zone 1 NAC Continuous 24VFWR 120VAC None Unknown None of the LEDs work Shane (Sprouse)
Mirtone

70605

Conventional 1 Zone 1 NAC Continuous 24VFWR 120VAC None Unknown My Rarest panel. I'm the only collector to own one Carl (Legacy)
Notifier

AFP-200C

Addressable 99 Points (Modules)

99 Points

(Detectors)

4 NACs Continuous, Temporal, 120BPM, California 24VDC 120VAC System Sensor, Wheelock, Gentex 2002 Carl

(Legacy)

EST

IO-1000

Addressable 1000 8 NACs Continuous, Temporal, Coder (Custom) 16.5 A 24VFWR 120VAC Genesis 2019 My favourite panel.


In a retrofit cabinet

Carl

(Legacy)

IBM

4201-2

(Soon to be obtained)

Coded N/A 2 4-4 120VAC 120VAC None 1940s Will be my oldest panel by far Glenn James

(Old School Fire Alarms)

Notification Appliances

Model Number Images Quantity Type Product Line Voltage Strobe Intensity Sound Output Manufacturing Date Notes Origin
Edwards

439D-6AWC

1 Vibrating Bell 24VDC 98db Unknown
Simplex

2901 2723

3 Motor Bell 24VDC Unkown 2012
Some old horn 1 Mechanical horn 12VAC 133db Unknown LOUD!!!!

looks looks like it could have a projector

EST

G1-HDVM

1 Horn/Strobe Genesis 24VDC Multi CD 103db Unkown AdenK2333
EST

G1-VM

2 Remote Strobe Genesis 24VDC Multi CD 2017 Carl (Lagacy)
Wheelock MT-241575W 1 Horn/Storbe 24VDC 15/75 CD Varying Unknown AdenK2333

Pull Stations

Model Number Image Quantity Type Manufacturing

Date

Notes Origin
Simplex

4251-20

1 Single Action

Single Stage

Conventional

Unknown AdenK2333
Couch

F1GG "Chevron"

1 Single Action

Single Stage

Conventional

Unknown Broke from being slammed Shane (Sprouse)
Notifier

NBG12LX

1 Dual Action

Single Stage

Conventional

Unknown Unknown
Notifier

LNG-1R

1 Dual Action

Single Stage

Conventional

Unknown YYCFireAlarmNimrod
Notifier

MPS-950B

1 Single Action

Single Stage

Conventional

Unknown YYCFireAlarmNimrod
Edwards

270-SPOW

1 Single Action

Single Stage

Conventional

Switch is no longer functional. Screw is so stripped its unusable Unknown

Automatic Detectors

Model Number Image Quantity Type Manufacturing

Date

Notes Origin
Edwards

C2M-PD

1 Photo Smoke

Conventional

2-Wire

Unknown YYCFireAlarmNimrod
EST

SIGA-PD

1 Photo Smoke

Addressable

2017 Came brand new EST Tech
Vigilant

V-HRD

1 Rate of Rise Heat

Addressable

Unknown Unknown
Notifier

FSP-851

1 Photo Smoke

Addressable

2018? Came new old stock Phuntington
Notifier

FSP-951

1 Photo Smoke

Addressable

2022 Came brand new Phuntington