Panels (FACP)
Model | Image | Type | Zone/Point Capacity | NACs | Coding Options | Power Supply | NAC Voltage | System Line Voltage | Synchronization Support | Manufacturing Date | Notes | Origin |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Edwards
2280 |
Conventional | 6 Zones | 2 NACs | Continuous | 24VDC | 120VAC | None | 1979 | My oldest panel | Carl
(Legacy) | ||
Fire Lite
Miniscan 112 |
Conventional | 4 Zones | 2 NACs | Continuous | 24VFWR | 120VAC | None | 1984 | In a box of stuff that I misplaced years ago | Shane
(Sprouse) | ||
Notifier/Emhart
Unknown Model |
Conventional | 1 Zone | 1 NAC | Continuous | 24VFWR | 120VAC | None | Unknown | None of the LEDs work | Shane (Sprouse) | ||
Mirtone
70605 |
Conventional | 1 Zone | 1 NAC | Continuous | 24VFWR | 120VAC | None | Unknown | My Rarest panel. I'm the only collector to own one | Carl (Legacy) | ||
Notifier
AFP-200C |
Addressable | 99 Points (Modules)
99 Points (Detectors) |
4 NACs | Continuous, Temporal, 120BPM, California | 24VDC | 120VAC | System Sensor, Wheelock, Gentex | 2002 | Carl
(Legacy) | |||
EST
IO-1000 |
Addressable | 1000 | 8 NACs | Continuous, Temporal, Coder (Custom) | 16.5 A | 24VFWR | 120VAC | Genesis | 2019 | My favourite panel.
|
Carl
(Legacy) | |
IBM
4201-2 (Soon to be obtained) |
Coded | N/A | 2
NACs |
4-4 | Variable (based on how you set the resistors ) always AC | 120VAC | None | 1940s | Will be my oldest panel by far | Glenn James
(Old School Fire Alarms) |
Notification Appliances
Model Number | Images | Quantity | Type | Product Line | Voltage | Strobe Intensity | Sound Output | Manufacturing Date | Notes | Origin |
---|---|---|---|---|---|---|---|---|---|---|
Edwards
439D-6AWC |
1 | Vibrating Bell | 24VDC | 98db | Unknown | |||||
Simplex
2901 2723 |
3 | Motor Bell | 24VDC | Unkown | 2012 | |||||
Some old horn | 1 | Mechanical horn | 12VAC | 133db | Unknown | LOUD!!!!
looks looks like it could have a projector |
||||
EST
G1-HDVM |
1 | Horn/Strobe | Genesis | 24VDC | Multi CD | 103db | Unkown | AdenK2333 | ||
EST
G1-VM |
2 | Remote Strobe | Genesis | 24VDC | Multi CD | 2017 | Carl (Lagacy) | |||
Wheelock MT-241575W | 1 | Horn/Storbe | 24VDC | 15/75 CD | Varying | Unknown | AdenK2333 |
Pull Stations
Model Number | Image | Quantity | Type | Manufacturing
Date |
Notes | Origin |
---|---|---|---|---|---|---|
Simplex
4251-20 |
1 | Single Action
Single Stage Conventional |
Unknown | AdenK2333 | ||
Couch
F1GG "Chevron" |
1 | Single Action
Single Stage Conventional |
Unknown | Broke from being slammed | Shane (Sprouse) | |
Notifier
NBG12LX |
1 | Dual Action
Single Stage Conventional |
Unknown | Unknown | ||
Notifier
LNG-1R |
1 | Dual Action
Single Stage Conventional |
Unknown | YYCFireAlarmNimrod | ||
Notifier
MPS-950B |
1 | Single Action
Single Stage Conventional |
Unknown | YYCFireAlarmNimrod | ||
Edwards
270-SPOW |
1 | Single Action
Single Stage Conventional |
Switch is no longer functional. Screw is so stripped its unusable | Unknown |
Automatic Detectors
Model Number | Image | Quantity | Type | Manufacturing
Date |
Notes | Origin |
---|---|---|---|---|---|---|
Edwards
C2M-PD |
1 | Photo Smoke
Conventional 2-Wire |
Unknown | YYCFireAlarmNimrod | ||
EST
SIGA-PD |
1 | Photo Smoke
Addressable |
2017 | Came brand new | EST Tech | |
Vigilant
V-HRD |
1 | Rate of Rise Heat
Addressable |
Unknown | Unknown | ||
Notifier
FSP-851 |
1 | Photo Smoke
Addressable |
2018? | Came new old stock | Phuntington | |
Notifier
FSP-951 |
1 | Photo Smoke
Addressable |
2021 | Came brand new | Phuntington |