| FACP: Mircom FX-2000 <br />System Type: Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />Date of last known Upgrade: 2020<br />Year Opened: 2006
| FACP: Mircom FX-2000  
|}
FACP Location: Main Entrance Vestibule<br />System Type: Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR  


‘’’Walmart’’’ is an American chain of supermarkets headquartered in Bentonville, Arkansas.  This particular store is a Supercentre, which is much larger, and has a full grocery department, with meat, produce, and a full deli and bakery.  This store is located in the Trainyards area of Ottawa, Ontario.  It was built in 2006, and had its fire alarm system replaced in 2020.
System Coding: Temporal


Strobes Synchronized: Yes<br />Date of last known Upgrade: 2020<br />Year Opened: 2006
|}
'''Walmart''' is an American chain of supermarkets headquartered in Bentonville, Arkansas. This particular store is a Supercentre, which is much larger, and has a full grocery department, with meat, produce, and a full deli and bakery. This store is located in the Trainyards area of Ottawa, Ontario. It was built in 2006, and had its fire alarm system replaced in 2020.
==System Specifications==
==System Specifications==
====FACP====
====FACP====
The store is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Mircom’s Advanced addressable protocol, and does code 3 in alarm.
The store is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Mircom’s Advanced addressable protocol, and the system coding is temporal.
 
====Notification Appliances====
====Notification Appliances====
All notification appliances are Mircom FHS-400-RR horn/strobes (red, wall-mount).
All notification appliances are Mircom FHS-400-RR horn/strobes (red, wall-mount).
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are Mircom MS-401AP addressable single-action pull stations.
All pull stations are Mircom MS-401AP addressable single-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
Not known.
Not known.
==System Specifications (2006-2020)==
==System Specifications (2006-2020)==
{| style="float:right;border:2px solid black"
{| style="float:right;border:2px solid black"
Line 31: Line 30:
|  
|  
|-
|-
| FACP: EST Quickstart QS4<br />System Type: Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />Year opened: <br />Year Decommissioned: 2006
| FACP: EST QuickStart QS4
FACP Location: Main Entrance Vestibule<br />System Type: Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR  
 
System Coding: Temporal
 
Strobes Synchronized: Yes <br />Year Decommissioned: 2020
|}
|}
This system was likely replaced due to a panel CPU fault.
This system was likely replaced due to a panel CPU fault.
====FACP====
====FACP====
The store was protected by an EST Quickstart QS4 addressable fire alarm system. The panel was located in the main entrance vestibule. The system ran EST’s Signature-series addressable protocol, and did code 3 in alarm.
The store was protected by an EST QuickStart QS4 addressable fire alarm system. The panel was located in the main entrance vestibule. The system ran EST’s Signature-series addressable protocol, the system coding was temporal.
 
====Notification Appliances====
====Notification Appliances====
All notification appliances were EST “Genesis” G1RF-HDVM horn/strobes (red, wall-mount, fire marking).
All notification appliances were EST “Genesis” G1RF-HDVM horn/strobes (red, wall-mount, FIRE marking).
 
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations were EST SIGA-270 addressable single-action pull stations.
All pull stations were EST SIGA-270 addressable single-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
Not known.
Not known.

Revision as of 12:39, 15 November 2022

System Specifications
FACP: Mircom FX-2000

FACP Location: Main Entrance Vestibule
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR

System Coding: Temporal

Strobes Synchronized: Yes
Date of last known Upgrade: 2020
Year Opened: 2006

Walmart is an American chain of supermarkets headquartered in Bentonville, Arkansas. This particular store is a Supercentre, which is much larger, and has a full grocery department, with meat, produce, and a full deli and bakery. This store is located in the Trainyards area of Ottawa, Ontario. It was built in 2006, and had its fire alarm system replaced in 2020.

System Specifications

FACP

The store is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Mircom’s Advanced addressable protocol, and the system coding is temporal.

Notification Appliances

All notification appliances are Mircom FHS-400-RR horn/strobes (red, wall-mount).

Initiating Devices

Pull Stations

All pull stations are Mircom MS-401AP addressable single-action pull stations.

Automatic Detection Devices

Not known.

System Specifications (2006-2020)

System Specifications
FACP: EST QuickStart QS4

FACP Location: Main Entrance Vestibule
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR

System Coding: Temporal

Strobes Synchronized: Yes
Year Decommissioned: 2020

This system was likely replaced due to a panel CPU fault.

FACP

The store was protected by an EST QuickStart QS4 addressable fire alarm system. The panel was located in the main entrance vestibule. The system ran EST’s Signature-series addressable protocol, the system coding was temporal.

Notification Appliances

All notification appliances were EST “Genesis” G1RF-HDVM horn/strobes (red, wall-mount, FIRE marking).

Initiating Devices

Pull Stations

All pull stations were EST SIGA-270 addressable single-action pull stations.

Automatic Detection Devices

Not known.