Billy Bishop Toronto City Airport: Difference between revisions

From FireAlarmPedia
(Added infobox.)
(Page completely rewritten to fit modern format.)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Notifier NFS2-3030C <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 70.7VRMS (Audibles) <br> 24VDC (visuals)<br />Date of last known Upgrade: N/A<br />Year Opened: 2010
| FACP: Notifier NFS2-3030C  
|}
FACP Location: Unknown<br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 70.7VRMS (Audibles) <br> 24VDC (visuals)


System Coding: Unknown


‘’’Billy Bishop Toronto City Airport’’’ is a regional airport located on Toronto Island, in Toronto, Ontario.  It is much smaller and less busy than Toronto Pearson, which is the busiest airport in Canada.  This terminal opened in 2010, and has the original fire alarm system.
Strobes Synchronized: Yes<br />Date of last known Upgrade: N/A<br />Year Opened: 2010
|}


'''Billy Bishop Toronto City Airport''' is a regional airport located on Toronto Island, in Toronto, Ontario, Canada. It is much smaller and less busy than Toronto Pearson, which is the busiest airport in Canada. This terminal opened in 2010, and has the original fire alarm system.
==System Specifications==
==System Specifications==
====FACP====
====FACP====
The airport is protected by a Notifier NFS2-3030C addressable fire alarm system.  The panel location is unknown, but the model has been confirmed by the size and age of the terminal, along with the devices on the system.  The system runs Notifier’s FlashScan addressable protocol, but the tones of the system are unknown.
The building is protected by a Notifier NFS2-3030C addressable fire alarm system.  The panel location is unknown.  The system runs Notifier's FlashScan addressable protocol, and is equipped with voice evacuation.  The system is configured for two-stage operation.  The messages and/or tones are unknown at this time.
 
====Notification Appliances====
====Notification Appliances====
All notification appliances are from System Sensor’s “SpectrAlert Advance” line of products.  Throughout the terminal, there is a mix of System Sensor SPSCWA speaker/strobes (white, ceiling-mount), System Sensor SPCWA remote speakers (white, ceiling-mount), and System Sensor SPSRA speaker/strobes (red, wall-mount).
Throughout the terminal, there is a mix of System Sensor "SpectrAlert Advance" SPSCWA speaker/strobes (white, ceiling-mount), System Sensor SPCWA remote speakers (white, ceiling-mount), and System Sensor SPSRA speaker/strobes (red, wall-mount).
 
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are Notifier MPS-950KB conventional two-stage single-action pull stations.  These have two Notifier FMM-101A addressable modules attached to them, as they are conventional.
All pull stations are Notifier MPS-950KB conventional two-stage single-action pull stations.  Each pull station is wired to two Notifier FMM-101A addressable monitor modules, both of which are located directly behind each station.
 
====Automatic Detection Devices====
====Automatic Detection Devices====
There are Notifier FSP-851A addressable photoelectric smoke detectors throughout the terminal.
There are Notifier FSP-851A addressable photoelectric smoke detectors throughout the terminal, mounted on System Sensor B210LPA low-profile bases..

Revision as of 11:38, 16 November 2022

System Specifications
FACP: Notifier NFS2-3030C

FACP Location: Unknown
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 70.7VRMS (Audibles)
24VDC (visuals)

System Coding: Unknown

Strobes Synchronized: Yes
Date of last known Upgrade: N/A
Year Opened: 2010

Billy Bishop Toronto City Airport is a regional airport located on Toronto Island, in Toronto, Ontario, Canada. It is much smaller and less busy than Toronto Pearson, which is the busiest airport in Canada. This terminal opened in 2010, and has the original fire alarm system.

System Specifications

FACP

The building is protected by a Notifier NFS2-3030C addressable fire alarm system. The panel location is unknown. The system runs Notifier's FlashScan addressable protocol, and is equipped with voice evacuation. The system is configured for two-stage operation. The messages and/or tones are unknown at this time.

Notification Appliances

Throughout the terminal, there is a mix of System Sensor "SpectrAlert Advance" SPSCWA speaker/strobes (white, ceiling-mount), System Sensor SPCWA remote speakers (white, ceiling-mount), and System Sensor SPSRA speaker/strobes (red, wall-mount).

Initiating Devices

Pull Stations

All pull stations are Notifier MPS-950KB conventional two-stage single-action pull stations. Each pull station is wired to two Notifier FMM-101A addressable monitor modules, both of which are located directly behind each station.

Automatic Detection Devices

There are Notifier FSP-851A addressable photoelectric smoke detectors throughout the terminal, mounted on System Sensor B210LPA low-profile bases..