Twentytwo22 (talk | contribs) (Created page with "{| style="float:right;border:2px solid black" |- !System Specifications |- | |- |FACP: EST QuickStart QS1 System Type:Addressable System Line Voltage: 120VAC NAC Voltage:2...") |
(Page rewritten.) |
||
Line 5: | Line 5: | ||
| | | | ||
|- | |- | ||
|FACP: | |FACP: Notifier NFS-320C | ||
FACP Location: Main Entrance | |||
System Type:Addressable | System Type:Addressable | ||
Line 12: | Line 12: | ||
System Line Voltage: 120VAC | System Line Voltage: 120VAC | ||
NAC Voltage: | NAC Voltage:24VDC | ||
System Coding: Temporal | |||
Strobes Synchronized: Yes | |||
Date of last known Upgrade: | Date of last known Upgrade: N/A | ||
Year Opened: | Year Opened: 2014 | ||
|}'''Bow Cliff Seniors''' is a Senior Activity Centre/Multi Purpose Space located | |}'''Bow Cliff Seniors''' is a Senior Activity Centre/Multi Purpose Space located at 3375 Spruce Drive Southwest, in Calgary, Alberta, Canada. The building opened in 2014, and the fire alarm system is original. The system was installed by Vipond and is currently serviced by AK Brown. | ||
==System Specifications== | ==System Specifications== | ||
===FACP=== | ===FACP=== | ||
The | The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Notifier's FlashScan addressable protocol, and the system coding is temporal. | ||
====Notification Appliances==== | ====Notification Appliances==== | ||
Most notification appliances are System Sensor "SpectrAlert Advance" PC2RA horn/strobes (red, ceiling-mount, set to 15cd). Some areas have System Sensor P2RA horn/strobes (red, wall-mount, set to 15cd). | |||
===Initiating Devices=== | ===Initiating Devices=== | ||
====Pull Stations==== | ====Pull Stations==== | ||
All pull stations are Notifier NBG-12LX | All pull stations are Notifier NBG-12LX addressable dual-action pull stations. | ||
====Automatic Detection Devices==== | ====Automatic Detection Devices==== | ||
There are Notifier FSP-851A | There are Notifier FSP-851A addressable photoelectric smoke detectors and and Notifier FST-851RA addressable rate-of-rise heat detectors throughout, mounted on System Sensor B210LPA low-profile bases. |
Revision as of 12:33, 17 November 2022
System Specifications |
---|
FACP: Notifier NFS-320C
FACP Location: Main Entrance System Type:Addressable System Line Voltage: 120VAC NAC Voltage:24VDC System Coding: Temporal Strobes Synchronized: Yes Date of last known Upgrade: N/A Year Opened: 2014 |
Bow Cliff Seniors is a Senior Activity Centre/Multi Purpose Space located at 3375 Spruce Drive Southwest, in Calgary, Alberta, Canada. The building opened in 2014, and the fire alarm system is original. The system was installed by Vipond and is currently serviced by AK Brown.
System Specifications
FACP
The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Notifier's FlashScan addressable protocol, and the system coding is temporal.
Notification Appliances
Most notification appliances are System Sensor "SpectrAlert Advance" PC2RA horn/strobes (red, ceiling-mount, set to 15cd). Some areas have System Sensor P2RA horn/strobes (red, wall-mount, set to 15cd).
Initiating Devices
Pull Stations
All pull stations are Notifier NBG-12LX addressable dual-action pull stations.
Automatic Detection Devices
There are Notifier FSP-851A addressable photoelectric smoke detectors and and Notifier FST-851RA addressable rate-of-rise heat detectors throughout, mounted on System Sensor B210LPA low-profile bases.