‘’’St. Anne Academic Centre’’’ is a school in the Calgary Catholic Separate School district (CSSD).  The school is located in the neighborhood of Ramsay, in Southeast Calgary.  The school opened in 1915, was renovated in 1993, and the fire alarm system is from 2013.
{| style="float:right;border:2px solid black"
|-
! System Specifications
|-
|
|-
| FACP: EST QuickStart QSC <br /> FACP Location: Unknown <br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br /> System Coding: Temporal <br> Strobes Synchronized: Yes <br />Date of last known Upgrade: 2013 <br />Year Opened: 1915
|}


'''St. Anne Academic Centre''' is a school in the Calgary Catholic Separate School district (CSSD). The school is located at 1010 21 Ave SE in the neighborhood of Ramsay, in Southeast Calgary. The school opened in 1915, was renovated in 1993, and the fire alarm system is from 2013.
==System Specifications==
==System Specifications==
====FACP====
====FACP====
The school is protected by an EST Quickstart QSC conventional fire alarm system. The panel location is unknown. The system does code 3 in alarm.
The school is protected by an EST Quickstart QSC conventional fire alarm system. The panel location is unknown. The system coding is temporal.
 
===== Annunciators =====


There is an EST QSA-1-S cabinet with a QSC-CPU-1 LCD annunciator and SL30 zone card past the main entrance.
====Notification Appliances====
====Notification Appliances====
All interior notification appliances are EST “Genesis” G1R-HDVM horn/strobes (red, wall-mount, set to 15cd). These are mounted on two-device boxes, with one device facing each end of the hallways. Outside, there are EST CS705-8A-T weatherproof remote strobes (red, wall-mount, 110cd).
All interior notification appliances are EST “Genesis” G1R-HDVM horn/strobes (red, wall-mount, set to 15cd). These are mounted on two-device boxes, with one device facing each end of the hallways. Outside, there are EST CS705-8A-T weatherproof remote strobes (red, wall-mount, 110cd).
 
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are Edwards 270-SPO conventional single-action pull stations. These were installed following the 1993 renovation, and are the oldest devices on the system.
All pull stations are Edwards 270-SPO conventional single-action pull stations. These were installed following the 1993 renovation, and are the oldest devices on the system.
 
====Automatic Detection Devices====
====Automatic Detection Devices====
Not currently known.
Not currently known.

Revision as of 21:39, 19 November 2022

System Specifications
FACP: EST QuickStart QSC
FACP Location: Unknown
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Strobes Synchronized: Yes
Date of last known Upgrade: 2013
Year Opened: 1915


St. Anne Academic Centre is a school in the Calgary Catholic Separate School district (CSSD). The school is located at 1010 21 Ave SE in the neighborhood of Ramsay, in Southeast Calgary. The school opened in 1915, was renovated in 1993, and the fire alarm system is from 2013.

System Specifications

FACP

The school is protected by an EST Quickstart QSC conventional fire alarm system. The panel location is unknown. The system coding is temporal.

Annunciators

There is an EST QSA-1-S cabinet with a QSC-CPU-1 LCD annunciator and SL30 zone card past the main entrance.

Notification Appliances

All interior notification appliances are EST “Genesis” G1R-HDVM horn/strobes (red, wall-mount, set to 15cd). These are mounted on two-device boxes, with one device facing each end of the hallways. Outside, there are EST CS705-8A-T weatherproof remote strobes (red, wall-mount, 110cd).

Initiating Devices

Pull Stations

All pull stations are Edwards 270-SPO conventional single-action pull stations. These were installed following the 1993 renovation, and are the oldest devices on the system.

Automatic Detection Devices

Not currently known.