Line 5: Line 5:
|  
|  
|-
|-
| FACP: Mircom FX-2000 <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />Date of last known Upgrade: 2010s <br />Year Opened: 2006  
| FACP: Mircom FX-2000 <br /> FACP Location: Main Entrance <br> System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br /> System Coding: Temporal <br> Strobes Synchronized: Yes, Mircom <br> Date of last known Upgrade: 2010s <br />Year Opened: 2006  
|}
|}
'''Chaparral Pointe Condos''' is a 3-story apartment building in the neighborhood of Chaparral, SE Calgary. This apartment complex was built in 2006, and has the original fire alarm system. The system is serviced by Armstrong Monitoring, and formerly Sprouse Fire & Safety.
'''Chaparral Pointe Condos''' is a 3-story apartment building located at 428 Chaparral Ravine View Southeast, in Calgary, Alberta, Canada. The building opened in 2006, and the fire alarm system is original with the exception of one notification appliance. The system is serviced by JAS Electric.  
== System Specifications (2006-present) ==
 
==== FACP ====
=== System Specifications (2006-present) ===
The fire alarm control panel is a Mircom FX-2000, original to the complex from 2006. The panel is located in the front entrance. When in alarm condition, the panel makes all horns (FHS-240R and MH-S25WA) do code-3, with all strobes synchronized.  The system runs Mircom's CLIP addressable protocol.  
 
=== FACP ===
The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main entrance vestibule.  The system runs Mircom's CLIP addressable protocol, and the system coding is temporal.  
==== Notification Appliances ====
==== Notification Appliances ====
The main notification appliances are Mircom FHS-240R horn/strobes in the hallways and lobby, original from 2006. The units have Mircom MH-S25WA silenceable mini horns, one per bedroom. The horns are loud enough to be heard throughout the units. The FHS-240R horn/strobes are set on high volume, electromechanical horn. In one of the units, a Mircom mini-horn in a bedroom broke down, and was replaced with a System Sensor "SpectrAlert Advance" MHWZA (white, silenceable) mini-horn.
All common area notification appliances are Mircom "Select-A-Horn/Strobe" FHS-240R horn/strobes (red, wall-mount, set to broadband/15cd). The suites have Mircom MH-S25WA silenceable mini-horns (white, wall-mount) in each bedroom.  One unit has a System Sensor "SpectrAlert Advance" MHWZA silenceable mini-horn (white, wall-mount) as a deficiency replacement.
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
All of the pull stations are original from 2006. They are Mircom MS-401AD CLIP addressable pull stations.
All pull stations are Mircom MS-401AD addressable single-action pull stations.
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
The hallways, stairwells, common areas and elevator lobbies have Mircom MIX-2251B CLIP addressable, photoelectric smoke detectors.
There are Mircom MIX-2251B addressable photoelectric smoke detectors throughout the common areas, mounted on System Sensor B710LPA low-profile bases.
 
==Known Activations==
==Known Activations==
April 2017 - smoke detector near unit 324 activated due to tenant burning toast. The system worked like it was supposed to, but many residents did not evacuate for some reason, possibly taken as a test. However, that was not a good idea.
April 2017 - smoke detector near unit 324 activated due to tenant burning toast. The system worked like it was supposed to, but many residents did not evacuate.

Revision as of 11:09, 21 November 2022

System Specifications
FACP: Mircom FX-2000
FACP Location: Main Entrance
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Strobes Synchronized: Yes, Mircom
Date of last known Upgrade: 2010s
Year Opened: 2006

Chaparral Pointe Condos is a 3-story apartment building located at 428 Chaparral Ravine View Southeast, in Calgary, Alberta, Canada. The building opened in 2006, and the fire alarm system is original with the exception of one notification appliance. The system is serviced by JAS Electric.

System Specifications (2006-present)

FACP

The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Mircom's CLIP addressable protocol, and the system coding is temporal.

Notification Appliances

All common area notification appliances are Mircom "Select-A-Horn/Strobe" FHS-240R horn/strobes (red, wall-mount, set to broadband/15cd). The suites have Mircom MH-S25WA silenceable mini-horns (white, wall-mount) in each bedroom. One unit has a System Sensor "SpectrAlert Advance" MHWZA silenceable mini-horn (white, wall-mount) as a deficiency replacement.

Initiating Devices

Pull Stations

All pull stations are Mircom MS-401AD addressable single-action pull stations.

Automatic Detection Devices

There are Mircom MIX-2251B addressable photoelectric smoke detectors throughout the common areas, mounted on System Sensor B710LPA low-profile bases.

Known Activations

April 2017 - smoke detector near unit 324 activated due to tenant burning toast. The system worked like it was supposed to, but many residents did not evacuate.