Comfort Inn & Suites South (Calgary): Difference between revisions

From FireAlarmPedia
(Found out it's an iO1000.)
(Page rewritten to fit modern format. Staff note: Please check the infoboxes before finalizing edits! This one still said EST2 even though we've confirmed it to be an iO1000.)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: EST2 <br />System Type:Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage:24VDC<br />Date of last known Upgrade: 2010s <br />Year Opened: 2000
| FACP: Edwards iO1000 <br /> FACP Location: Main Entrance <br> System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC<br /> System Coding: Temporal <br> Date of last known Upgrade: 2010s <br />Year Opened: 2000
|}
|}
'''Comfort Inn''' is a hotel chain owned by Choice Hotels. They are headquartered in Rockville, Maryland. This particular hotel is located in Calgary, Alberta, Canada. It was built in 2000, and the fire alarm system is original except for one device.
'''Comfort Inn''' is a hotel chain owned by Choice Hotels. They are headquartered in Rockville, Maryland. This particular hotel is located at 4611 Macleod Trail Southwest, in Calgary, Alberta, Canada. The hotel opened in 2000, and the fire alarm system is original with the exception of one mini horn and the main FACP.
==System Specifications==
==System Specifications==
====FACP====
====FACP====
The hotel is protected by an EST iO1000 addressable fire alarm system. The panel is located in the main entrance vestibule.  The panel model was confirmed via driveby on Macleod Trail. The system runs EST’s Signature-series addressable protocol, and does code 3 in alarm.
The building is protected by an Edwards iO1000 addressable fire alarm system. The panel is located in the main entrance vestibule.  The system runs Edwards' Signature-series addressable protocol, and the system coding is temporal.
====Notification Appliances====
====Notification Appliances====
Most notification appliances are from EST’s “Integrity” line of products. Most areas have Edwards 757-7A-T horn/strobes (red, wall-mount, 15/75cd). The guest rooms have EST “PowerSaver Integrity” 202-75PS remote strobes (red, wall-mount, 75cd), along with Edwards 683-1CR silenceable mini horns. In a jacuzzi suite, the mini horn broke down, and was replaced with a System Sensor “SpectrAlert Advance” MHWZA silenceable mini horn (white, wall-mount).
All common area notification appliances are Edwards "Integrity" 757-7A-T horn/strobes (red, wall-mount, 15/75cd). The guest rooms have Edwards "PowerSaver Integrity" 202-75PS remote strobes (red, wall-mount, 75cd) and Edwards 683-1CR silenceable mini-horns (red, wall-mount). One jacuzzi suite has a System Sensor "SpectrAlert Advance" MHWZA silenceable mini-horn (white, wall-mount) as a deficiency replacment.
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are EST SIGA-270 Signature-series addressable single-action pull stations.
All pull stations are EST SIGA-270 addressable single-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
There are EST SIGA-PS Signature-series addressable photoelectric smoke detectors throughout the hotel.
There are EST SIGA-PS addressable photoelectric smoke detectors throughout the hotel, mounted on EST SIGA-SB bases.

Revision as of 15:01, 21 November 2022

System Specifications
FACP: Edwards iO1000
FACP Location: Main Entrance
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Date of last known Upgrade: 2010s
Year Opened: 2000

Comfort Inn is a hotel chain owned by Choice Hotels. They are headquartered in Rockville, Maryland. This particular hotel is located at 4611 Macleod Trail Southwest, in Calgary, Alberta, Canada. The hotel opened in 2000, and the fire alarm system is original with the exception of one mini horn and the main FACP.

System Specifications

FACP

The building is protected by an Edwards iO1000 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Edwards' Signature-series addressable protocol, and the system coding is temporal.

Notification Appliances

All common area notification appliances are Edwards "Integrity" 757-7A-T horn/strobes (red, wall-mount, 15/75cd). The guest rooms have Edwards "PowerSaver Integrity" 202-75PS remote strobes (red, wall-mount, 75cd) and Edwards 683-1CR silenceable mini-horns (red, wall-mount). One jacuzzi suite has a System Sensor "SpectrAlert Advance" MHWZA silenceable mini-horn (white, wall-mount) as a deficiency replacment.

Initiating Devices

Pull Stations

All pull stations are EST SIGA-270 addressable single-action pull stations.

Automatic Detection Devices

There are EST SIGA-PS addressable photoelectric smoke detectors throughout the hotel, mounted on EST SIGA-SB bases.