Safeway (Dalhousie): Difference between revisions

From FireAlarmPedia
(Overhaul from drive!)
mNo edit summary
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Simplex 4007ES <br /> FACP Location: Main Entrance Vestibule <br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: Temporal <br> Strobes Synchronized: Yes <br />Date of last known Upgrade: 2021 <br />Year Opened: 1996
| FACP: Simplex 4007ES <br /> FACP Location: Main Entrance Vestibule <br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: Temporal <br> Strobes Synchronized: Yes, SmartSync<br />Date of last known Upgrade: 2021 <br />Year Opened: 1996
|}
|}
 
'''Safeway Canada''' is a Canadian grocery store chain owned by Sobeys. This particular store is located at 5005 Dalhousie Drive Northwest #100, in Calgary, Alberta, Canada. The store opened in 1996, and the fire alarm system is from 2021.
'''Safeway Canada''' is a Canadian grocery store chain owned by Sobeys. This particular store is located at 5005 Dalhousie Drive Northwest #100, in Calgary, Alberta, Canada. The store opened in 1996, and the fire alarm system is from 2021.
 
==System Specifications (2021-present)==
==System Specifications (2021-present)==
Please note that some system information is unconfirmed. This page should not be used for official purposes.
Please note that some system information is unconfirmed. This page should not be used for official purposes.
====FACP====
====FACP====
The building is protected by a Simplex 4007ES conventional fire alarm system. The panel is located in the main entrance vestibule. The system coding is temporal.
The building is protected by a Simplex 4007ES conventional fire alarm system. The panel is located in the main entrance vestibule. The system coding is temporal.
 
====Notification Appliances====
====Notification Appliances====
Most notification appliances are Simplex “TrueAlert” 4906-9127 horn/strobes (red, wall-mount). There are Simplex 4906-9104 remote strobes (white, ceiling-mount) located throughout the store on the ceiling. There is a Simplex 4906-9105 weatherproof remote strobe (red, wall-mount) outside the building.
Most notification appliances are Simplex “TrueAlert” 4906-9127 horn/strobes (red, wall-mount). There are Simplex 4906-9104 remote strobes (white, ceiling-mount) located throughout the store on the ceiling. There is a Simplex 4906-9105 weatherproof remote strobe (red, wall-mount) outside the building.
 
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All storefront pull stations are Simplex 2099-9754 conventional single-action pull stations. The backroom has Edwards 270-SPO conventional single-action pull stations, leftover from the old system.
All storefront pull stations are Simplex 2099-9754 conventional single-action pull stations. The backroom has Edwards 270-SPO conventional single-action pull stations, leftover from the old system.
 
====Automatic Detection Devices====
====Automatic Detection Devices====
The store is equipped with a sprinkler system, and no detectors are present in the storefront.
The store is equipped with a sprinkler system, and no detectors are present in the storefront.
==System Specifications (1996-2021)==
==System Specifications (1996-2021)==
====FACP====
====FACP====
The building was protected by an EST 6632 conventional fire alarm system. The panel was located in the main entrance vestibule. The system coding was continuous.
The building was protected by an EST 6632 conventional fire alarm system. The panel was located in the main entrance vestibule. The system coding was continuous.
 
====Notification Appliances====
====Notification Appliances====
Most notification appliances were Edwards 439D-10AWC vibrating bells (10” gong), mounted on Edwards 403-5A-001 strobe plates (15cd). There was one Wheelock RSSP-24MCW strobe plate in the floral department as a deficiency replacement; the Edwards bell remained intact. The centre areas of the store had Edwards 202-5A-001 remote strobes (red, wall-mount, 15cd) and Edwards 202-5A-001 remote strobes (white, wall-mount, 15cd) on the ceiling. There were also System Sensor “SpectrAlert Advance” SRA (red, wall-mount) remote strobes on the ceiling, as deficiency replacements. For exterior notification, there was an Edwards 439D-10AWC bell on EST 403-5A-001 strobe plate outside the entrance.
Most notification appliances were Edwards 439D-10AWC vibrating bells (10” gong), mounted on Edwards 403-5A-001 strobe plates (15cd). There was one Wheelock RSSP-24MCW strobe plate in the floral department as a deficiency replacement; the Edwards bell remained intact. The centre areas of the store had Edwards 202-5A-001 remote strobes (red, wall-mount, 15cd) and Edwards 202-5A-001 remote strobes (white, wall-mount, 15cd) on the ceiling. There were also System Sensor “SpectrAlert Advance” SRA (red, wall-mount) remote strobes on the ceiling, as deficiency replacements. For exterior notification, there was an Edwards 439D-10AWC bell on EST 403-5A-001 strobe plate outside the entrance.
 
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations were Edwards 270-SPO conventional single-action pull stations.
All pull stations were Edwards 270-SPO conventional single-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
Not known.
Not known.

Revision as of 00:14, 22 November 2022

System Specifications
FACP: Simplex 4007ES
FACP Location: Main Entrance Vestibule
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes, SmartSync
Date of last known Upgrade: 2021
Year Opened: 1996

Safeway Canada is a Canadian grocery store chain owned by Sobeys. This particular store is located at 5005 Dalhousie Drive Northwest #100, in Calgary, Alberta, Canada. The store opened in 1996, and the fire alarm system is from 2021.

System Specifications (2021-present)

Please note that some system information is unconfirmed. This page should not be used for official purposes.

FACP

The building is protected by a Simplex 4007ES conventional fire alarm system. The panel is located in the main entrance vestibule. The system coding is temporal.

Notification Appliances

Most notification appliances are Simplex “TrueAlert” 4906-9127 horn/strobes (red, wall-mount). There are Simplex 4906-9104 remote strobes (white, ceiling-mount) located throughout the store on the ceiling. There is a Simplex 4906-9105 weatherproof remote strobe (red, wall-mount) outside the building.

Initiating Devices

Pull Stations

All storefront pull stations are Simplex 2099-9754 conventional single-action pull stations. The backroom has Edwards 270-SPO conventional single-action pull stations, leftover from the old system.

Automatic Detection Devices

The store is equipped with a sprinkler system, and no detectors are present in the storefront.

System Specifications (1996-2021)

FACP

The building was protected by an EST 6632 conventional fire alarm system. The panel was located in the main entrance vestibule. The system coding was continuous.

Notification Appliances

Most notification appliances were Edwards 439D-10AWC vibrating bells (10” gong), mounted on Edwards 403-5A-001 strobe plates (15cd). There was one Wheelock RSSP-24MCW strobe plate in the floral department as a deficiency replacement; the Edwards bell remained intact. The centre areas of the store had Edwards 202-5A-001 remote strobes (red, wall-mount, 15cd) and Edwards 202-5A-001 remote strobes (white, wall-mount, 15cd) on the ceiling. There were also System Sensor “SpectrAlert Advance” SRA (red, wall-mount) remote strobes on the ceiling, as deficiency replacements. For exterior notification, there was an Edwards 439D-10AWC bell on EST 403-5A-001 strobe plate outside the entrance.

Initiating Devices

Pull Stations

All pull stations were Edwards 270-SPO conventional single-action pull stations.

Automatic Detection Devices

Not known.