Crystal Palace: Difference between revisions

From FireAlarmPedia
mNo edit summary
(Page rewritten to fit modern format. Model of smokes is 4098-9714, no suffix. The 9714EA is the Australia version.)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Simplex 4007ES <br />System Type:Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage:24VDC <br />Date of last known Upgrade: N/A <br />Year Opened: circa 2014
| FACP: Simplex 4007ES <br /> FACP Location: Main Entrance <br> System Type:Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage:24VDC <br /> System Coding: Temporal <br> Strobes Synchronized: Yes, IDNAC <br> Date of last known Upgrade: N/A <br />Year Opened: circa 2014
|}
|}
'''Crystal Palace''' is a small commercial building in Renfrew it is unknown for sure when this building was constructed, however it appears to have been constructed in the past 10 years and the system is likely original.
'''Crystal Palace''' is a small commercial building located at 622 Edmonton Trail, in Calgary, Alberta, Canada.  The building opened in 2018, and the fire alarm system is original.
 
==System Specifications==
==System Specifications==
====FACP ====
====FACP ====
The FACP is a Simplex 4007ES likely installed during construction.
The building is protected by a Simplex 4007ES addressable fire alarm system.  The panel is located at the main entrance.  The system runs Simplex's IDNet addressable initiating protocol and Simplex's IDNAC addressable notification protocol, and the system coding is temporal.




====Notification Appliances====
====Notification Appliances====
All of the devices are Simplex "TrueAlert ES" 49AV-WRF (red, wall) addressable horn/strobes.
All notification appliances are Simplex "TrueAlert ES" 49AV-WRF addressable horn/strobes (red, wall-mount, set to 15cd).
 
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
The pull stations consist of Simplex 4099-9004 single action, addressable pull stations with an LED.
All pull stations are Simplex 4099-9004 addressable single-action pull stations.
 
====Automatic Detection Devices====
====Automatic Detection Devices====
 
There are Simplex "TrueAlarm" 4098-9714 addressable photoelectric smoke detectors throughout the building, mounted on Simplex 4098-9792 addressable bases.
There are Simplex 4098-9714EA addressable photoelectric smoke detectors.

Revision as of 11:36, 22 November 2022

System Specifications
FACP: Simplex 4007ES
FACP Location: Main Entrance
System Type:Addressable
System Line Voltage: 120VAC
NAC Voltage:24VDC
System Coding: Temporal
Strobes Synchronized: Yes, IDNAC
Date of last known Upgrade: N/A
Year Opened: circa 2014

Crystal Palace is a small commercial building located at 622 Edmonton Trail, in Calgary, Alberta, Canada. The building opened in 2018, and the fire alarm system is original.

System Specifications

FACP

The building is protected by a Simplex 4007ES addressable fire alarm system. The panel is located at the main entrance. The system runs Simplex's IDNet addressable initiating protocol and Simplex's IDNAC addressable notification protocol, and the system coding is temporal.


Notification Appliances

All notification appliances are Simplex "TrueAlert ES" 49AV-WRF addressable horn/strobes (red, wall-mount, set to 15cd).

Initiating Devices

Pull Stations

All pull stations are Simplex 4099-9004 addressable single-action pull stations.

Automatic Detection Devices

There are Simplex "TrueAlarm" 4098-9714 addressable photoelectric smoke detectors throughout the building, mounted on Simplex 4098-9792 addressable bases.