Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

TwentyThree33's Basement: Difference between revisions

From FireAlarmPedia
No edit summary
(Added proper demo box. Also, stop being so cringy with the do not pull fire alarms shit. This is a documentation site. We don't need to remind people of the obvious. If I catch one of you doing it again. I'll bitch you out.)
Line 1: Line 1:
 
{| cellspacing="5" cellpadding="0" style="margin: 0em 0em 1em 0em; border: 1px solid #1DA0E7;  background: #B3DDF4; width: 100%"
| '''''This is a hobby system and is not powered on 24/7 and therefore does not provide any reliable fire protection. This page is for demonstration purposes only.'''''
|}
[[Category:Hobby]]
[[Category:Hobby]]
{| style="float:right;border:2px solid black"
{| style="float:right;border:2px solid black"
Line 14: Line 16:
'''YYCsFireAlarmNimrod's Basement (name may be subject to change)''' is a basement in Calgary, built in 2003. It has a mini fire alarm system owned and serviced by [[User:Yycsfirealarmnimrod|User:YYCsFireAlarmNimrod]].  
'''YYCsFireAlarmNimrod's Basement (name may be subject to change)''' is a basement in Calgary, built in 2003. It has a mini fire alarm system owned and serviced by [[User:Yycsfirealarmnimrod|User:YYCsFireAlarmNimrod]].  
== System Specifications ==
== System Specifications ==
*Note: This is not a life safety system. This system is for demonstration purposes only. He can pull the alarm on it any time he wants to without being fined as it is a controlled environment. NEVER pull a fire alarm unless there is actually a fire emergency.
==== FACP ====
==== FACP ====
The current FACP in this basement is a Notifier AFP-200C addressable fire alarm panel. It was made in 2003, and was previously in use at [[40 Sunpark Plaza SE]]. The panel was removed due to NAC troubles, but the culprit was found to have been bent prongs on the horn/strobe terminals. This panel is in immaculate condition, and is fully functional, with no troubles or any other issues. This is the third panel this system has had since it was installed in August 2020. The previous panel was a Simplex 4010, and the original panel was a Fire-Lite MS-4. The system runs Notifier's CLIP addressable protocol. When in alarm, the system does march time.
The current FACP in this basement is a Notifier AFP-200C addressable fire alarm panel. It was made in 2003, and was previously in use at [[40 Sunpark Plaza SE]]. The panel was removed due to NAC troubles, but the culprit was found to have been bent prongs on the horn/strobe terminals. This panel is in immaculate condition, and is fully functional, with no troubles or any other issues. This is the third panel this system has had since it was installed in August 2020. The previous panel was a Simplex 4010, and the original panel was a Fire-Lite MS-4. The system runs Notifier's CLIP addressable protocol. When in alarm, the system does march time.

Revision as of 23:32, 8 December 2022

This is a hobby system and is not powered on 24/7 and therefore does not provide any reliable fire protection. This page is for demonstration purposes only.
System Specifications
FACP: Notifier AFP-200C
System Line Voltage: 120VAC
NAC Voltage: 24VDC

System Type: Addressable (Hybrid Manner)
Date of last upgrade: 2022
Year Built: 2003

NOTE: This page is being heavily edited due to a panel change in this fire alarm system. It is also updated every time he gets a new fire alarm device.

YYCsFireAlarmNimrod's Basement (name may be subject to change) is a basement in Calgary, built in 2003. It has a mini fire alarm system owned and serviced by User:YYCsFireAlarmNimrod.

System Specifications

FACP

The current FACP in this basement is a Notifier AFP-200C addressable fire alarm panel. It was made in 2003, and was previously in use at 40 Sunpark Plaza SE. The panel was removed due to NAC troubles, but the culprit was found to have been bent prongs on the horn/strobe terminals. This panel is in immaculate condition, and is fully functional, with no troubles or any other issues. This is the third panel this system has had since it was installed in August 2020. The previous panel was a Simplex 4010, and the original panel was a Fire-Lite MS-4. The system runs Notifier's CLIP addressable protocol. When in alarm, the system does march time.

In late 2022, the panel may be replaced with a Notifier NFS2-640C, following the upgrade at Marlborough Mall. This will only occur if the NFS2-640C is running on a software version that is compatible with Verifire 5.7.

Notification Appliances

The notification appliances are currently a Simplex 2901-9720 motor bell (6"), along with the following devices being wired as strobes, with all horn/strobes having the horn disconnected: Siemens ZR-MC-W-B, Wheelock MT-241575W-FR, Edwards 757-5A-T, System Sensor SRA, Kidde "Genesis" EG1R-VM, Edwards 892-2B, Simplex 4903-9219, and System Sensor P4RLA.

Initiating Devices

Pull Stations

The current pull stations vary, but these are accurate as of 2/28/2022. The bottom left of the board has a Notifier N-MPS-SA addressable single-action pull station. Right above the N-MPS-SA is a Notifier N-MPS-2A addressable two-stage pull station, mounted on a Simplex backbox. The two-stage switch on this pull station is wired to trip the "disco lights", which are unsynchronized strobes that serve as party lights. This pull station is also equipped with a Notifier MPS-LP dual-action conversion kit. Next to the N-MPS-2A is a Pyr-A-Larm MS-51 bilingual conventional single-action pull station. This pull station is wired into a Notifier FMM-101A addressable module from the mid 2000s. Next to the MS-51 is a Notifier LNG-1R conventional dual-action pull station. This pull station is wired into a Notifier MMX-101A addressable module, which will likely be upgraded to an FMM-101A if the panel is replaced. Below the LNG-1R is a Siemens MS-53C two-stage single-action pull station. Only the pull station is hooked up; the GA switch is not in use. This pull station is wired into a Notifier FMM-1A addressable module, which was chosen in favor of an FMM-101A due to a lack of wire length, and only having 4" backboxes at the time of installation.

Automatic Detection Devices

There is currently only one detector on this system. It is a Notifier FSL-751A VIEW (Very Intelligent Early Warning) laser smoke detector. It was removed from the Enmax headquarters in Calgary. Bonus Info: The JCI tech known as Vic said to Yycsfirealarmnimrod that this detector "belonged to the garbage can". Naturally, Yycsfirealarmnimrod put the detector in his backpack before anyone noticed.