Banff Caribou Lodge & Spa: Difference between revisions

From FireAlarmPedia
No edit summary
No edit summary
Line 46: Line 46:


January 2020 - alarm early in the morning. Cause unknown, however everybody was safe.
January 2020 - alarm early in the morning. Cause unknown, however everybody was safe.
[[Category:Facilities]]
[[Category:Facilitie]

Revision as of 12:40, 3 April 2023

System Specifications
FACP: Simplex 4100U

FACP Location: Unknown
System Type:Addressable
System Line Voltage: 120VAC
NAC Voltage:24VDC

System Coding: Continuous?

Strobes Synchronized: No
Date of last known Upgrade: N/A
Year Opened: 1993

Banff Caribou Lodge & Spa is a 3 star hotel located at 521 Banff Avenue, in Banff, Alberta, Canada. It houses a mountain lodge-style hotel, a spa, and a steakhouse. The building opened in 1993, and most of the fire alarm system is original.

System Specifications (1993-present)

FACP

The hotel is protected by a Simplex 4100U addressable fire alarm system. The panel location is unknown, but is confirmed by the picture next to the annunciator having the InfoAlarm Command Center. The system runs Simplex’s MAPNET II addressable protocol, and the system coding is likely continuous. The 4100U replaced the original 4100+

Annunciators

There is a Simplex 4603-9101 LCD annunciator at the entrance.

Notification Appliances

Most notification appliances are Simplex 2901-9722 motor bells (10” gong). There are also Simplex 4904-9101 remote strobes scattered throughout the hotel.

Guest Rooms

The rooms have Wheelock MIZ-24-WS mini horn/strobes (red, wall-mount).

Initiating Devices

Pull Stations

All pull stations are Simplex 2099-9795 addressable single-action pull stations.

Automatic Detection Devices

None noticed.

List of known activations

January 2010 - alarm at 2:00 AM. False activation confirmed by staff.

February 2012 - alarm at 11:30 PM, smoke detector in stairwell activated by cigarette smoke, confirmed by fire department and hotel staff. Multiple guests reported the scent of smoke. First mistaken as smoke from the fireplace. Hotel was not evacuated, however everybody was safe.

May 2013 - alarm at 12:15 AM. False activation, guests reported to lobby, alarm silenced soon after.

December 2013 - alarm at 2:30 AM. False activation confirmed by staff.

June 2014 - alarm at midnight. Cause unknown and likely false activation. Everybody was safe.

August 2017 - alarm at 10:00 PM. Hotel was evacuated and cause was later found to be false.

July 2018 - alarm sometime in evening. Guests were overwhelmed by the volume of the alarm. Cause was likely false.

January 2020 - alarm early in the morning. Cause unknown, however everybody was safe. [[Category:Facilitie]