Calgary Co-op (Shawnessy): Difference between revisions

From FireAlarmPedia
No edit summary
No edit summary
Line 37: Line 37:
====Automatic Detection Devices====
====Automatic Detection Devices====
None noticed.
None noticed.
[[Category:Facilitie]
[[]

Revision as of 13:58, 3 April 2023

System Specifications
FACP: EST QuickStart QS1
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
Date of last known Upgrade: 2016
Year Opened: 1991

Calgary Co-op is a chain of grocery stores in the Calgary area. This particular store was built in 1991, and renovated in about 2016. The current fire alarm system is from 2016, and the previous system was from around 2006. For some unknown reason, they are basically the same. No details are known about the original system.

System Specifications

FACP

The current fire alarm panel is an EST QuickStart QS1 from 2016. It replaced a 2006 variant following a renovation. It is unknown why they replaced the panel with another identical panel in the same spot, as they could've saved money by just wiring the new devices into the original panel. The system does code-3 in alarm, as this is the only coding that the notification appliances can do without significant modifications.

Notification Appliances

The notification appliances are all from EST's "Genesis" line of products. They mostly consist of EST G1R-HDVM (red, wall, no FIRE) horn/strobes, and some EST GC-HDVM (white, ceiling, no FIRE) ceiling-mount horn/strobes. These were also installed in 2016, replacing older variants.

Initiating Devices

Pull Stations

The pull stations consist of EST SIGA-270 addressable pull stations, installed in 2016 with the current EST logo. They replaced older variants.

Automatic Detection Devices

All smoke detectors consist of EST SIGA-PS addressable photoelectric smoke detectors.

Former System Specifications

System Specifications
FACP: EST QuickStart QS1
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
Date of last known Upgrade: N/A
Year Decommissioned: 2016

FACP

The previous fire alarm panel was also an EST QuickStart QS1, but from 2006. It is unknown why this panel was replaced in 2016, but possibly a CPU fault during reprogramming.

Notification Appliances

All previous notification appliances consisted of EST "Genesis" G1R-HDVM (red, wall, no FIRE) horn/strobes. All horn/strobes have been replaced.

Initiating Devices

Pull Stations

The previous pull stations consisted of EST SIGA-270 addressable pull stations from 2006. These were replaced in 2016 with newer variants.

Automatic Detection Devices

None noticed. [[]