Mid-Mountain Lodge (Nakiska): Difference between revisions

From FireAlarmPedia
No edit summary
(Overhauled. Series 2280)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Mircom FA-1000 <br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />Date of last known Upgrade: circa 2007 <br />Year Opened: 1987  
| FACP: Mircom Series 1000  
FACP Location: Back Exit<br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR  
 
System Coding: Temporal?<br />Date of last known Upgrade: circa 2007 <br />Year Opened: 1987
|}
|}
The '''Mid Mountain Lodge''' is another daylodge in Nakiska Ski Resort, except this one is in the middle of the mountain, right off the top of the Olympic Chairlift. Most likely this daylodge was built in 1987 when the chairlift was added. Just like the main daylodge, the panel is not original, but in the original panel's cabinet.
The '''Mid Mountain Lodge''' is the daylodge located mid-mountain at Nakiska Ski Resort, in Kananaskis, AB. It is located right at the top of the Olympic Chairlift, and was built in 1987 along with the chairlift. Most of the system except for the panel is original.
== System Specifications ==
== System Specifications ==
==== FACP ====
==== FACP ====
The lodge is protected by a Mircom FA-1000 fire alarm system. It was installed around 2007. It replaced the original Edwards 2280, but the FA-1000 is in the 2280 cabinet. The panel is located in an exit.
The building is protected by a Mircom Series 1000 conventional fire alarm system. The panel is located in the back exit, and is in an Edwards 2280 cabinet; the Series 1000 replaced it in 2007. The system coding is likely temporal.
==== Notification Appliances ====
==== Notification Appliances ====
The notification appliances are all the original Edwards 439D-6AWC vibrating bells.
All notification appliances are Edwards 439D-6AWC vibrating bells (6" gong).
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
The pull stations are a mix of Edwards 274-111 and Edwards 275-C111 pull stations, again all original.
The pull stations are a mix of Edwards 275-C111 pull stations and Edwards 274-111 pull stations.  
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
The smoke detectors are System Sensor C2W-BA photoelectric i3 smoke detectors, and the heat detectors are Edwards 280B-PL mechanical heat detectors which are original.
All smoke detectors are Mircom "i3" 2W-BA photoelectric smoke detectors. The heat detectors are Edwards 281C rate-of-rise/fixed temperature heat detectors, which have most likely been replaced since they were recalled in 2020.
[[Category:Facilities]]
[[Category:Facilities]]
[[Category:Facilities]]
[[Category:Facilities]]

Revision as of 15:46, 27 November 2023

System Specifications
FACP: Mircom Series 1000

FACP Location: Back Exit
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR

System Coding: Temporal?
Date of last known Upgrade: circa 2007
Year Opened: 1987

The Mid Mountain Lodge is the daylodge located mid-mountain at Nakiska Ski Resort, in Kananaskis, AB. It is located right at the top of the Olympic Chairlift, and was built in 1987 along with the chairlift. Most of the system except for the panel is original.

System Specifications

FACP

The building is protected by a Mircom Series 1000 conventional fire alarm system. The panel is located in the back exit, and is in an Edwards 2280 cabinet; the Series 1000 replaced it in 2007. The system coding is likely temporal.

Notification Appliances

All notification appliances are Edwards 439D-6AWC vibrating bells (6" gong).

Initiating Devices

Pull Stations

The pull stations are a mix of Edwards 275-C111 pull stations and Edwards 274-111 pull stations.

Automatic Detection Devices

All smoke detectors are Mircom "i3" 2W-BA photoelectric smoke detectors. The heat detectors are Edwards 281C rate-of-rise/fixed temperature heat detectors, which have most likely been replaced since they were recalled in 2020.