| FACP: Edwards EST2 <br /> FACP Location: Main Entrance <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: 20BPM (First Stage) <br> Temporal (GA) <br> Strobes Synchronized: Yes, EST <br />Date of last known Upgrade: N/A <br />Year Opened: 2001
| FACP: Edwards EST2 <br /> FACP Location: Main Entrance <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: 20BPM (Alert) <br> Temporal (Alarm) <br> Strobes Synchronized: Yes, EST <br />Date of last known Upgrade: N/A <br />Year Opened: 2001
|}
|}
 
'''Royal Hotel''' is a chain of midrange hotels owned by Wyndham. The chain is headquartered in Parsippany, New Jersey, USA, and has locations worldwide. This particular hotel is located at 8450 Sparrow Drive, in Leduc, Alberta, Canada. The hotel primarily serves travelers from the nearby [[Edmonton International Airport]]. The hotel opened in 2001, and the fire alarm system is original.
'''Royal Hotel''' is a chain of midrange hotels owned by Wyndham. The chain is headquartered in Parsippany, New Jersey, USA, and has locations worldwide. This particular hotel is located at 8450 Sparrow Drive, in Leduc, Alberta, Canada. The hotel primarily serves travelers from the nearby [[Edmonton International Airport]]. The hotel opened in 2001, and the fire alarm system is original.
==System Specifications (2001-present)==
 
==System Specifications==
====FACP====
====FACP====
The building is protected by an Edwards EST2 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Edwards’ Signature addressable protocol, and is configured for two-stage operation. First stage coding is 20BPM, followed by temporal in general alarm.
The building is protected by an Edwards EST2 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Edwards’ Signature addressable protocol, and is configured for two-stage operation. The alert signal coding is 20BPM, followed by temporal for the evacuation signal.
 
====Notification Appliances====
====Notification Appliances====
=====Common Areas=====
=====Common Areas=====
Line 19: Line 16:
=====Guest Rooms=====
=====Guest Rooms=====
All guest rooms have Edwards 683-1C silenceable mini-horns (white, wall-mount) and Edwards 202-75PSW remote strobes (white, wall-mount, 75cd).
All guest rooms have Edwards 683-1C silenceable mini-horns (white, wall-mount) and Edwards 202-75PSW remote strobes (white, wall-mount, 75cd).
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are EST SIGA-270P addressable two-stage single-action pull stations.
All pull stations are EST SIGA-270P addressable two-stage single-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
All public areas of the hotel are protected by a sprinkler system with waterflow detection. As such, no detectors are present in these areas.
All public areas of the hotel are protected by a sprinkler system with waterflow detection. As such, no detectors are present in these areas.
 
====Modules====
====Modules====
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
[[Category:Facilities]]
[[Category:Facilities]]

Revision as of 23:34, 10 December 2023

System Specifications
FACP: Edwards EST2
FACP Location: Main Entrance
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: 20BPM (Alert)
Temporal (Alarm)
Strobes Synchronized: Yes, EST
Date of last known Upgrade: N/A
Year Opened: 2001

Royal Hotel is a chain of midrange hotels owned by Wyndham. The chain is headquartered in Parsippany, New Jersey, USA, and has locations worldwide. This particular hotel is located at 8450 Sparrow Drive, in Leduc, Alberta, Canada. The hotel primarily serves travelers from the nearby Edmonton International Airport. The hotel opened in 2001, and the fire alarm system is original.

System Specifications (2001-present)

FACP

The building is protected by an Edwards EST2 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Edwards’ Signature addressable protocol, and is configured for two-stage operation. The alert signal coding is 20BPM, followed by temporal for the evacuation signal.

Notification Appliances

Common Areas

There are Edwards “Integrity Powersaver” 757H-15PSW horn/strobes (white, wall-mount, 15cd) throughout the common areas of the hotel.

Guest Rooms

All guest rooms have Edwards 683-1C silenceable mini-horns (white, wall-mount) and Edwards 202-75PSW remote strobes (white, wall-mount, 75cd).

Initiating Devices

Pull Stations

All pull stations are EST SIGA-270P addressable two-stage single-action pull stations.

Automatic Detection Devices

All public areas of the hotel are protected by a sprinkler system with waterflow detection. As such, no detectors are present in these areas.

Modules

There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.