Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Walmart Supercentre (Leduc): Difference between revisions

From FireAlarmPedia
No edit summary
mNo edit summary
Line 6: Line 6:
|  
|  
|-
|-
| FACP: Simplex 4100U <br /> FACP Location: Right Entrance Vestibule <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: Temporal <br> Strobes Synchronized: Yes <br />Date of last known Upgrade: 2017 <br />Year Opened: 2004  
| FACP: Simplex 4100U <br /> FACP Location: Right Entrance Vestibule <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: Temporal <br> Strobes Synchronized: Yes, SmartSync<br />Date of last known Upgrade: 2017 <br />Year Opened: 2004
|}
|}
'''Walmart''' is a retail store chain. This particular location is located at 5302 Discovery Way in the city of Leduc, AB. It was built in 2004, and underwent an expansion in 2017. The store retains its original fire alarm system.
'''Walmart''' is a retail store chain. This particular location is located at 5302 Discovery Way in the city of Leduc, AB. It was built in 2004, and underwent an expansion in 2017. The store retains its original fire alarm system.
== System Specifications ==
== System Specifications (2004-present) ==




==== FACP ====
==== FACP ====
The store is protected by a Simplex 4100U addressable fire alarm system. The panel is located in the right entrance vestibule, and is 3 bays. The panel is also equipped with the InfoAlarm Command Center. The system runs Simplex's IDNet addressable protocol, and the system coding is Temporal.  
The store is protected by a Simplex 4100U addressable fire alarm system. The panel is located in the right entrance vestibule, and is 3 bays. The panel is also equipped with the InfoAlarm Command Center. The system runs Simplex's IDNet addressable protocol, and the system coding is T]temporal.  
==== Notification Appliances ====
==== Notification Appliances ====
All notification appliances are from Simplex's "TrueAlert" line of products. Throughout the store, the notification appliances are mounted on pillars, with two horn/strobes and two remote strobes, both opposite each other. The horn/strobes are Simplex 4906-9127 horn/strobes (red, wall-mount), and the strobes are Simplex 4906-9101 remote strobes (red, wall-mount). Some areas with lower ceilings have Simplex 4906-9128 horn/strobes (red, ceiling-mount). The garden center's horn strobe was installed in 2017.
All notification appliances are from Simplex's "TrueAlert" line of products. Throughout the store, the notification appliances are mounted on pillars, with two horn/strobes and two remote strobes, both opposite each other. The horn/strobes are Simplex 4906-9127 horn/strobes (red, wall-mount, set to 15cd), and the strobes are Simplex 4906-9101 remote strobes (red, wall-mount, set to 15cd). Some areas with lower ceilings have Simplex 4906-9128 horn/strobes (red, ceiling-mount, set to 30cd). The garden center's horn strobe, a Simplex 4906-9127, was installed in 2017.
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
All pull stations are Simplex 4099-9001 addressable single-action pull stations.  
All pull stations are Simplex 4099-9001 addressable single-action pull stations.  
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
There are Simplex "TrueAlarm" 4098-9714 addressable photoelectric smoke detectors in the bakery.
There are Simplex "TrueAlarm" 4098-9714 addressable photoelectric smoke detectors in the bakery. The storefront is protected by waterflow.
 
==== Modules ====
There are Simplex 4090-9001 addressable monitor modules supervising the sprinkler system's tamper and flow switches.
[[Category:Facilities]]
[[Category:Facilities]]
[[Category:Facilities]]
[[Category:Facilities]]

Revision as of 02:17, 13 December 2023

System Specifications
FACP: Simplex 4100U
FACP Location: Right Entrance Vestibule
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes, SmartSync
Date of last known Upgrade: 2017
Year Opened: 2004

Walmart is a retail store chain. This particular location is located at 5302 Discovery Way in the city of Leduc, AB. It was built in 2004, and underwent an expansion in 2017. The store retains its original fire alarm system.

System Specifications (2004-present)

FACP

The store is protected by a Simplex 4100U addressable fire alarm system. The panel is located in the right entrance vestibule, and is 3 bays. The panel is also equipped with the InfoAlarm Command Center. The system runs Simplex's IDNet addressable protocol, and the system coding is T]temporal.

Notification Appliances

All notification appliances are from Simplex's "TrueAlert" line of products. Throughout the store, the notification appliances are mounted on pillars, with two horn/strobes and two remote strobes, both opposite each other. The horn/strobes are Simplex 4906-9127 horn/strobes (red, wall-mount, set to 15cd), and the strobes are Simplex 4906-9101 remote strobes (red, wall-mount, set to 15cd). Some areas with lower ceilings have Simplex 4906-9128 horn/strobes (red, ceiling-mount, set to 30cd). The garden center's horn strobe, a Simplex 4906-9127, was installed in 2017.

Initiating Devices

Pull Stations

All pull stations are Simplex 4099-9001 addressable single-action pull stations.

Automatic Detection Devices

There are Simplex "TrueAlarm" 4098-9714 addressable photoelectric smoke detectors in the bakery. The storefront is protected by waterflow.

Modules

There are Simplex 4090-9001 addressable monitor modules supervising the sprinkler system's tamper and flow switches.