More actions
Twentytwo22 (talk | contribs) No edit summary |
mNo edit summary |
||
Line 5: | Line 5: | ||
| | | | ||
|- | |- | ||
| FACP: Notifier NFS-320C | | FACP: Notifier NFS-320C | ||
FACP Location: Unconfirmed<br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC | FACP Location: Unconfirmed<br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC | ||
Line 13: | Line 13: | ||
|} | |} | ||
'''Real Canadian Superstore''' is a chain of supermarkets owned by Loblaws. This particular store is located at Unit 100 3633 Westwinds Dr NE in the Westwinds neighborhood of Northeast Calgary. The store opened in 2005, and had its system replaced in the 2010s. | '''Real Canadian Superstore''' is a chain of supermarkets owned by Loblaws. This particular store is located at Unit 100 3633 Westwinds Dr NE in the Westwinds neighborhood of Northeast Calgary. The store opened in 2005, and had its system replaced in the 2010s. | ||
==System Specifications== | ==System Specifications (2010s-present)== | ||
====FACP==== | ====FACP==== | ||
The store is protected by a Notifier NFS-320C addressable fire alarm system. The panel is likely located in one entrance, but this is unconfirmed. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal. | The store is protected by a Notifier NFS-320C addressable fire alarm system. The panel is likely located in one entrance, but this is unconfirmed. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal. |
Revision as of 13:57, 15 December 2023
System Specifications |
---|
FACP: Notifier NFS-320C
FACP Location: Unconfirmed System Coding: Temporal Strobes Synchronized: Yes |
Real Canadian Superstore is a chain of supermarkets owned by Loblaws. This particular store is located at Unit 100 3633 Westwinds Dr NE in the Westwinds neighborhood of Northeast Calgary. The store opened in 2005, and had its system replaced in the 2010s.
System Specifications (2010s-present)
FACP
The store is protected by a Notifier NFS-320C addressable fire alarm system. The panel is likely located in one entrance, but this is unconfirmed. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.
Annunciators
There are two annunciator modules at the south entrance. One is a Notifier LCD2-80 annunciator, and the other is a Notifier ACM-24AT 24-LED annunciator.
Notification Appliances
All notification appliances are System Sensor “SpectrAlert Advance” P2RA horn/strobes (red, wall-mount).
Initiating Devices
Pull Stations
All pull stations are Notifier N-MPS-SA addressable single-action pull stations.
Automatic Detection Devices
There may be some smoke detectors, although this is unconfirmed.
System Specifications (2005-2010s)
System Specifications |
---|
FACP: EST QuickStart QS1
FACP Location: Main Entrance System Coding: Temporal Strobes Synchronized: Yes |
Please note that this is purely speculation, and is based off the previous system at the Deerfoot Meadows location.
FACP
The store was protected by an EST QuickStart QS1 addressable fire alarm system. The panel was located in one entrance. The system ran EST’s Signature-series addressable protocol, and the system coding was temporal.
Notification Appliances
All notification appliances were EST “Genesis” G1R-HDVM horn/strobes (red, wall-mount).
Initiating Devices
Pull Stations
All pull stations were EST SIGA-270 addressable single-action pull stations.
Automatic Detection Devices