7520 Macleod Trail SE, Calgary: Difference between revisions

From FireAlarmPedia
No edit summary
(Overhauled)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Notifier NFS-320C <br />System Type:Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage:24VDC <br />Date of last known Upgrade: 2018 <br />Year Opened: 1975
| FACP: Notifier NFS-320C
FACP Location Unknown <br />System Type:Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage:24VDC  
 
System Coding: Temporal
 
Strobes Synchronized: Yes, SS<br />Date of last known Upgrade: 2018 <br />Year Opened: 1975
|}
|}
'''7520 Macleod Trail SE''' is the address of a building in the Fairview Industrial area of Southeast Calgary. It was built in 1975 as Lloyd’s Recreation Centre, a roller rink. However, due to a lack of patronage, the rink closed in 2017, and was converted into Visions Electronics. The current system was installed in 2018, following the conversion of the building. This page will showcase both the current and previous systems.
'''7520 Macleod Trail SE''' is the address of a building in the Fairview Industrial area of Southeast Calgary. It was built in 1975 as Lloyd’s Recreation Centre, a roller rink. However, due to a lack of patronage, the rink closed in 2017, and was converted into Visions Electronics. The current system was installed in 2018, following the conversion of the building. This page will showcase both the current and previous systems.
==System Specifications==
==System Specifications (2018-present)==
NOTE: This system is unconfirmed, and is based on typical Notifier systems from this time.
NOTE: This system is unconfirmed, and is based on typical Notifier systems from this time.
====FACP====
====FACP====
The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel location is unknown, and was installed in 2018. The system runs Notifier's FlashScan addressable protocol, and does code 3 in alarm.  
The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel location is unknown, and was installed in 2018. The system runs Notifier's FlashScan addressable protocol, and the system coding is temporal.  
====Notification Appliances====
====Notification Appliances====
All notification appliances are System Sensor “L Series” P2RLA horn/strobes (red, wall-mount, bilingual lettering). They are set on code 3 electromechanical.
All notification appliances are System Sensor “L Series” P2RLA horn/strobes (red, wall-mount, bilingual lettering, set to 15cd, electromechanical)
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
The pull stations are likely Notifier NBG-12LX addressable dual-action pull stations.
The pull stations are likely Notifier NBG-12LX addressable dual-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
There are likely Notifier FSP-851A addressable photoelectric smoke detectors throughout the building.
There is a sprinkler system with waterflow detection, so there are no visible detectors.
 
==== Modules ====
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system's tamper and flow switches.
 
==Original System Specifications (Lloyd’s)==
==Original System Specifications (Lloyd’s)==
{| style="float:right;border:2px solid black"
{| style="float:right;border:2px solid black"
Line 26: Line 35:
|  
|  
|-
|-
| FACP: Edwards Custom 6500 <br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />Date of last known Upgrade: N/A <br />Year Decommissioned: 2017
| FACP: Edwards Custom 6500  
FACP Location: Main Office?<br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC  
 
System Coding: Continuous<br />Date of last known Upgrade: N/A <br />Year Decommissioned: 2017
|}
|}
====FACP====
====FACP====
The building was protected by the original Edwards Custom 6500 conventional fire alarm system. The panel was likely located in the main office, and probably did march time or continuous in alarm. The system lasted a mere 42 years before being replaced, with no upgrades.
The building was protected by the original Edwards Custom 6500 conventional fire alarm system. The panel was likely located in the main office, the system coding was likely continuous.
 
The system lasted a mere 42 years before being replaced, with no upgrades.
====Notification Appliances====
====Notification Appliances====
The notification appliances were Edwards “Durabel” 6100D vibrating bells (6” gong), which were also original.
The notification appliances were Edwards “Durabel” 6100D vibrating bells (6” gong).  
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations were third-generation Edwards 270-SPO single-action “teardrop” pull stations.  
All pull stations were third-generation Edwards 270-SPO single-action pull stations.  
====Automatic Detection Devices====
====Automatic Detection Devices====
None, as codes did not require detectors at that time.
None, as codes did not require detectors at that time.
[[]
[[]

Revision as of 03:04, 16 December 2023

System Specifications
FACP: Notifier NFS-320C

FACP Location Unknown
System Type:Addressable
System Line Voltage: 120VAC
NAC Voltage:24VDC

System Coding: Temporal

Strobes Synchronized: Yes, SS
Date of last known Upgrade: 2018
Year Opened: 1975

7520 Macleod Trail SE is the address of a building in the Fairview Industrial area of Southeast Calgary. It was built in 1975 as Lloyd’s Recreation Centre, a roller rink. However, due to a lack of patronage, the rink closed in 2017, and was converted into Visions Electronics. The current system was installed in 2018, following the conversion of the building. This page will showcase both the current and previous systems.

System Specifications (2018-present)

NOTE: This system is unconfirmed, and is based on typical Notifier systems from this time.

FACP

The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel location is unknown, and was installed in 2018. The system runs Notifier's FlashScan addressable protocol, and the system coding is temporal.

Notification Appliances

All notification appliances are System Sensor “L Series” P2RLA horn/strobes (red, wall-mount, bilingual lettering, set to 15cd, electromechanical)

Initiating Devices

Pull Stations

The pull stations are likely Notifier NBG-12LX addressable dual-action pull stations.

Automatic Detection Devices

There is a sprinkler system with waterflow detection, so there are no visible detectors.

Modules

There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system's tamper and flow switches.

Original System Specifications (Lloyd’s)

System Specifications
FACP: Edwards Custom 6500

FACP Location: Main Office?
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VDC

System Coding: Continuous
Date of last known Upgrade: N/A
Year Decommissioned: 2017

FACP

The building was protected by the original Edwards Custom 6500 conventional fire alarm system. The panel was likely located in the main office, the system coding was likely continuous.

The system lasted a mere 42 years before being replaced, with no upgrades.

Notification Appliances

The notification appliances were Edwards “Durabel” 6100D vibrating bells (6” gong).

Initiating Devices

Pull Stations

All pull stations were third-generation Edwards 270-SPO single-action pull stations.

Automatic Detection Devices

None, as codes did not require detectors at that time. [[]