| FACP: EST1 <br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC | | FACP: Edwards EST1 | ||
FACP Location: Main Entrance Vestibule<br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC | |||
System Coding: Contiuous | |||
Strobes Synchronized: Yes, self-sync<br />Date of last known Upgrade: N/A <br />Year Opened: 1997 <br /> Year Demolished: 2020 | |||
|} | |||
'''Montana's''' is a restaurant chain in Canada. This location was at 112 Crowfoot Terrace NW, Calgary, AB. It was built in 1997, closed in 2018, and was finally demolished in early 2020. The fire alarm system remained original throughout its time. | |||
== Former System Specifications (1997-2020) == | |||
==== FACP ==== | ==== FACP ==== | ||
The building was protected by an Edwards EST1 conventional fire alarm system. The panel was located in the main entrance vestibule. The system coding was continuous. | |||
The | |||
==== Notification Appliances ==== | ==== Notification Appliances ==== | ||
All notification appliances were Edwards 439D-6AWC vibrating bells (6" gong) on EST "Integrity" 403-5A-R strobe plates (15cd). | |||
=== Initiating Devices === | === Initiating Devices === | ||
==== Pull Stations ==== | ==== Pull Stations ==== | ||
All pull stations were Edwards 270-SPO conventional pull stations. | |||
All | |||
==== Automatic Detection Devices ==== | ==== Automatic Detection Devices ==== | ||
None noticed, but there were Edwards 281C conventional rate-of-rise/fixed heat detectors in the kitchen. | |||
None were | |||
[[Category:Facilities]] | [[Category:Facilities]] | ||
[[Category:Facilities]] | [[Category:Facilities]] |
Revision as of 12:37, 20 December 2023
System Specifications |
---|
FACP: Edwards EST1
FACP Location: Main Entrance Vestibule System Coding: Contiuous Strobes Synchronized: Yes, self-sync |
Montana's is a restaurant chain in Canada. This location was at 112 Crowfoot Terrace NW, Calgary, AB. It was built in 1997, closed in 2018, and was finally demolished in early 2020. The fire alarm system remained original throughout its time.
Former System Specifications (1997-2020)
FACP
The building was protected by an Edwards EST1 conventional fire alarm system. The panel was located in the main entrance vestibule. The system coding was continuous.
Notification Appliances
All notification appliances were Edwards 439D-6AWC vibrating bells (6" gong) on EST "Integrity" 403-5A-R strobe plates (15cd).
Initiating Devices
Pull Stations
All pull stations were Edwards 270-SPO conventional pull stations.
Automatic Detection Devices
None noticed, but there were Edwards 281C conventional rate-of-rise/fixed heat detectors in the kitchen.